background image

 
        Manual Part No: 931762-01 

                   MV1 Gas Steamer 

    - 13 – 

        Manual Rev No: 2 

 

Users Instructions (cont.) 

 
 
Controls Operation: 
 
Control Knob - 

Controls multifunction valve to allow gas to flow to main and pilot burners 
marked with 

z

 “

OFF

”, * “

PILOT

” and the flame symbol “

ON

” positions. 

Water Taps - 

Inlet tap controls flow of water into steamer. Drain tap allows water tank to be 
drained. 

 
Lighting the Steamer: 
 

WARNING:

 - 

DO NOT LIGHT BURNERS WHEN TANK IS EMPTY 

 

Ensure that water supply to steamer is turned on before use. 

 
1)

 

Open both internal and external stop valves. Remove steamer furniture and interceptor tray. 
Check that water level is up to mark on rear of steamer tank. Open and close drain tap and check 
that ball valve operates, to bring water back to correct level. 

 
2)

 

Replace steamer furniture and interceptor tray. Turn control knob from 

z

 “

OFF

” to * “

PILOT

”, 

push in knob and press piezo ignition to light the pilot. 

 
3)

 

Hold in knob for approximately 20 seconds, release and check that pilot remains alight. 

 
4)

 

If pilot is extinguished on releasing knob, repeat steps 2 & 3. If pilot remains alight, turn control 
knob to “

ON

” to light main burner. 

 
5)

 

When main burner flames are established, close steamer door. Wait for 20 minutes whilst 
steamer reaches full temperature, then open the door in accordance with special safety 
procedure given below. Load steamer quickly with food and close door securely. 

 
6)

 

A fixed calibration thermostat controls steamer, which is not adjustable, by the user. When set 
temperature is reached thermostat cuts burner off. 

 

Note:

 - When first lighting the appliance after installation or after an extended shut-down period, it may 

be necessary for gas control knob to remain pushed in for some time before pilot will light, 
owing to presence of air in gas line. 

 
Turning off the Steamer: 
 
1)

 

For short periods, turn control knob to * “

PILOT

”. 

 
2)

 

For long periods, turn control knob to 

z

 “

OFF

”, close all external gas stop valves, if fitted, and 

external and internal water valves. Drain tank and thoroughly dry inside of tank. 

Содержание MV1STA60-LP

Страница 1: ...MV 1 SERIES GAS STEAMER OWNER S MANUAL Click here for Parts List Country of Destination GB and IE Manual Part No 931762 01 MV1 Gas Steamer 1 Manual Rev No 2 ...

Страница 2: ... 01 MV1 Gas Steamer 2 Manual Rev No 2 Model No Product Description Rev Date Flexible Hose Size MV1STA60 NG MV1STA60 LP MV Gas Steamer 600 Steamer 2 Stage Door 600 Steamer 2 Stage Door 2 2 14 10 05 14 10 05 BSP hose BSP hose ...

Страница 3: ...n 4 Important Note 5 Specification 6 7 Gas Pressure Connection 6 Dimensions 7 Installation 8 10 Important Note 8 Positioning 8 Checking Commissioning 8 10 User s Instruction 11 13 Important Note 11 Operation 12 13 Cooking Guide 13 Cleaning 13 Service Maintenance 14 16 Instructions 14 15 Fault Finding 16 Spare Parts 17 18 Warranty Cover Sheet 19 ...

Страница 4: ...s of the FIRE PRECAUTIONS ACT 1971 the HEALTH SAFETY AT WORK ETC ACT 1974 the BUILDING STANDARDS SCOTLAND CONSOLIDATION REGULATIONS 1971 Detailed recommendations are contained in British Standards BS5440 Part 1 2000 BS5440 Part 2 2000 BS5588 Part 0 1996 BS5588 Part 11 1997 BS6173 2001 An easily accessible stopcock must be fitted in the gas supply adjacent to the appliance for use in emergency The ...

Страница 5: ... burns therefore the appliance should be positioned to minimise the possibility of accidental touching It is the supervisor s responsibility to warn users to wear suitable protection and to follow correct operation and cleaning procedures For the details of your nearest Service Agent for all warranty and repair work you should contact The Service Manager Viscount Catering Limited Provincial Park N...

Страница 6: ... Connections Gas BSP Taper Male Rp Water 15 mm When connecting using a flexible hose fit a BSP hose Heat Input Nett Natural Gas Propane Gas Inj m3 hr Btu hr kW Inj kg hr Btu hr kW Full Rate 3 3 1 708 55 952 16 4 2 1 1 26 54 933 16 1 Air Requirements Area 600 Steamer 72 cm2 11 in2 Oven Dimensions Oven cavity 498 mm wide x 610 mm deep x 650 mm high Weight 200kg ...

Страница 7: ...Specification cont 700 600 35 35 35 230 180 445 305 900 150 1674 DRAIN WATER GAS 803 768 1709 35 Manual Part No 931762 01 MV1 Gas Steamer 7 Manual Rev No 2 ...

Страница 8: ...rotective film adhering to the stainless steel panels should be left on until installation is completed BUT THIS MUST BE REMOVED BEFORE COMMISSIONING OR OPERATING THE APPLIANCE Check appliance Data Plate located at the top rear of the appliance to ensure appliance is correct for local gas supply Note During installation always employ accepted standards of gas fitting and National Water Council pra...

Страница 9: ...he appliance 3 Provide a rigid water supply pipe no smaller than the size of the inlet together with an elbow or other suitable means of connection Note Although rigid pipe is recommended a flexible hose of a type approved for potable water may be used 4 It is recommended that an easily accessible stop tap be provided adjacent to the appliance 5 Connect steamer to gas water supplies ensuring that ...

Страница 10: ...to correct level 4 Connect a water gauge to pressure test point on burner injector elbow light appliance and check that the pressure shown on gauge agrees with that on Data Plate 5 Check the pressure and adjust if required 6 Check that pilot flame impinges correctly on flame failure thermopile and thermocouple to ensure operation of burner Adjust pilot flame if necessary using adjusting screw see ...

Страница 11: ... 3 Remove Injector Elbow together with injector by undoing hexagon nut Replace with new injector Part No 931767 21 and re fit Injector Elbow assembly Finally tighten hexagon nut 4 Unscrew governor cap screw on Control Valve and remove adjusting screw and spring Replace with Governor Exclusion Screw Part No 931767 14 and re fit cap screw 5 Finally fit Data Plate and re test appliance as described i...

Страница 12: ...n be necessary you are advised to contact your nearest CORGI Confederation for the Registration of Gas Installers Service Engineer immediately The need for regular servicing is detailed in the GAS SAFETY INSTALLATION USE REGULATIONS 2000 IF YOU THINK THAT GAS IS ESCAPING ACT IMMEDIATELY SHUT OFF THE GAS SUPPLY AT THE METER OR EMERGENCY CONTROL CONTACT THE SUPPLIER OF YOUR GAS IMMEDIATELY MAKE SURE...

Страница 13: ... knob for approximately 20 seconds release and check that pilot remains alight 4 If pilot is extinguished on releasing knob repeat steps 2 3 If pilot remains alight turn control knob to ON to light main burner 5 When main burner flames are established close steamer door Wait for 20 minutes whilst steamer reaches full temperature then open the door in accordance with special safety procedure given ...

Страница 14: ...er surfaces using soap and water or a suitable detergent Rinse with clean water and dry thoroughly 3 Clean external surfaces in a similar manner to inner surfaces WARNING DO NOT USE CAUSTIC OR ABRASIVE CLEANERS Cooking Guide The times given below are a guide to the anticipated performance of the steamer fully loaded with the stated food To prevent possible over cooking carry out normal cooking che...

Страница 15: ... and attention at all times Frequent cleaning and regular checking of correct adjustment will be rewarded by reduced operating and maintenance costs minimum downtime and regular results from your cooking WE RECOMMEND THAT ALL EQUIPMENT IS SERVICED AT LEAST ONCE A YEAR BUT MAY BE AS FREQUENT AS 6 MONTHS OR LESS SERVICE INTERVALS CAN BE AFFECTED BY SPILLAGE AND SHOULD BE ASSESSED EACH TIME THE EQUIP...

Страница 16: ...move the two screws fixing the control panel and check that the float switch operation is satisfactory by depressing the float below the water level noting that the main burner goes out and then re lights as the float switch is released Also check that the cross lighting between pilot and burner is smooth and positive Any scale build up on the float switch or float valve must be removed 5 Replace ...

Страница 17: ... Remove thermostat by undoing its two fixing screws 7 Disconnect the two wires on the thermostat 8 Replace new part by reversing the above procedure Thermocouple Thermopile 1 Disconnect from the multifunctional valve 2 Remove the three screws fastening the bottom heat shield and withdraw followed by the three screws fixing the top heat shield 3 Unscrew thermocouple thermopile and withdraw from the...

Страница 18: ...w valve and refit by reversing removal procedure 6 Turn on water supply and check operation of inlet valve see TESTING on page 9 Doors Steamer Compartment 1 Remove caps from door hinges exposing fixing screws 2 Release fixing screws being careful not to lose spacing shim 3 Repeat step 2 and lift door away 4 Refit by reversing removal procedure Burner Compartment 1 Remove two screws securing bottom...

Страница 19: ...ow Clean re adjust Explosive Ignition Gas pressure low Set to correct pressure No water supply to steamer Check supply Float switch in header tank damaged or scale build up impairing operation of float mechanism Replace or de scale as required Thermostat faulty Replace Poor or open connections Repair or remake connections Thermopile failure Should generate 350 mv open circuit Should generate 100 m...

Страница 20: ...tch 2 Stage 1 931646 01 Door Handle Bottom 1 924169 01 Generator Tank Cover 1 012908 04 Air Release Valve Body 1 012908 02 Cap 1 D12910 3 Locknut 1 016867 Sealing Washer 1 920180 2 Valve Hole Cover 1 930656 02 Burner 1 931767 25 Burner Injector NG 3 3mm 1 931767 21 Burner Injector LP 2 1mm 1 928654 01 Float Valve 1 X04120 Ball Float 1 309011 Float Switch 1 931767 01 Control Valve 1 931767 14 Gover...

Страница 21: ...f Stainless steel Optional 920515 02 Baskets Stainless Steel Optional XC60S PS Shelf Kit Aluminium Optional XC60S SS Shelf Kit Stainless steel Optional XC60S SB Basket Accessory Kit Stainless Steel Optional 931980 G1 Wire Assembly Spares Kit 931811 S1 Conversion Kit NG to LPG Spares Kit 931811 S2 Conversion Kit LPG to NG Spares Kit Spare Parts are available from Viscount Catering Limited Provincia...

Страница 22: ... The Company will not be obliged to repair or replace any goods if after examination the defect damage is found to be through accident misuse neglect incorrect installation or maintenance by other than approved engineers or any other cause beyond the reasonable control of the manufacturer EXCLUSIONS TO WARRANTY Normal routine maintenance is not covered and the warranty specifically excludes any pr...

Страница 23: ...Manual Part No 931762 01 MV1 Gas Steamer 23 Manual Rev No 2 ...

Отзывы: