Manual Part No: 932971-01 MD Gas Convection Oven
Page 16 of 32
Manual Rev No: 1
Installation (cont.)
Checking and commissioning (cont.)
Remove the cap in order to gain access to the pressure adjusting screw.
Turn the pressure adjusting screw clockwise to increase the pressure or anti-clockwise to decrease it.
When the pressure reading is correct, refit the cap to the governor.
Turn the gas supply to the unit
OFF
at the stopcock and disconnect the manometer (U Tube). Ensure that
the pressure test point screw is refitted.
Turn the gas supply to the appliance on at the stopcock and leak test the pressure test point.
Burner Aeration
The aeration of all the burners is fixed and does not need adjusting.