background image

TPS400

May

 201

6

206-791-00

C

TRUNKGUARD 

®

Fieldbus Power Supply 

TR

UNKGU

ARD 

®

Fieldb

us P

o

w

er Supply

TPS400

Содержание TRUNKGUARD TPS400

Страница 1: ...TPS400 May 2016 206 791 00C TRUNKGUARD Fieldbus Power Supply TRUNKGUARD Fieldbus Power Supply TPS400...

Страница 2: ...nections 7 Terminator 7 Grounding 8 Case Ground 8 Shield Ground 8 Surge Ground 8 Recommended Ground Wiring Practices 8 Testing and Troubleshooting 9 LED Operation 9 CE Conformity 10 Operation 10 Maint...

Страница 3: ...odules for each segment Modules are hot swappable with load sharing in redundant pairs to maintain power to the segment in the instance that one module in a pair needs to be removed Universal Modules...

Страница 4: ...mal ORANGE Out put Voltage 18V LED Short GREEN normal RED Cable Short LED Open GREEN normal RED Carrier Fault FDM252 Fieldbus Diag nostics Module Power Dissipation 0 5W maximum LED Type GREEN Normal R...

Страница 5: ...Figure 2 Dimensions for The TRUNKGUARD TPS401 Simplex Dimensions 114mm 4 50in TPS401 4D TPS401 4Y 300mm 8 5in TPS400 121mm 4 75in Figure 3 Dimensions for The TRUNKGUARD TPS402 Duplex 114mm 4 50in 356...

Страница 6: ...e on board screws to secure the module to the Carrier Fieldbus Diagnostics Modules are required for alarm indication and alarm contact output but removal or non installation does not affect the power...

Страница 7: ...re recommended for use with stranded cable Field side segment wiring is made via screw clamp pluggable terminals marked FIELD HOST connections are made either through the terminals marked HOST or via...

Страница 8: ...onnected to the normal SHIELD ground When used for surge protection the shorting bar between these ground points must be removed Therefore if no surge protection is being used this shorting bar must b...

Страница 9: ...OISE 2 NOISE 3 NOISE 4 LED Indication GREEN RED OFF Normal Operation Input Voltage A 18V Module failure GREEN RED OFF Normal Operation Input Voltage B 18V Module failure GREEN RED OFF Normal Operation...

Страница 10: ...quirements for programmed maintenance TPS400 Series modules contain no user serviceable parts Non functioning units under warranty should be returned to Moore Industries for replacement or repair Moor...

Страница 11: ...D 800HSE FDM252 Segment 2 Segment 3 Segment 4 Segment 2 Segment 3 Segment 4 TPS400 Segment 1_1A Fieldbus Cable Fieldbus Cable Fieldbus Cable Control Network HSE Subnet Server AC 800M LD 800HSE LD 800H...

Страница 12: ...utilizes Series 2 H1 cards To install TRUNKGUARD with an Emerson DeltaV system refer to Figure A 2 Segment 1_1A Emerson Series 2 H1 Card Series 2 H1 Card FDM252 Segment 2 Segment 3 Segment 4 TPS400 S...

Страница 13: ...System Configuration To utilize TRUNKGUARD with a Yokogawa CENTUM system refer to Figure A 3 below AKB336 AKB336 AKB336 FDM252 TPS400 FDM252 Segment 2 Segment 2 Segment 3 Segment 4 Segment 3 Segment...

Страница 14: ...the TPS 400 Carrier board Refer to Figure A 4 below FDM252 Segment 2 Segment 3 Segment 4 TPS400 DB37 DB25 Cable DB37 DB25 Cable FDM252 Segment 2 Segment 3 Segment 4 Simplex TPS401 4D Duplex TPS402 4D...

Страница 15: ...implex TPS401 4D Duplex TPS402 4D Honeywell Series C FIM 1 2 3 4 SEGMENT 1 SEGMENT 1 Honeywell Series C FIM 1 2 3 4 DB25 16 pin Cable Segments 1 4 Multi Segments with alarm connections P N 804 013 26...

Страница 16: ...BREACH OF ANYWARRANTY CONCERNINGTHE GOODS OR SERVICES SHALL BE FOR THE COMPANY AT ITS OPTION TO REPAIR OR REPLACE THE GOODS OR SERVICES OR REFUND THE PURCHASE PRICE THE COMPANY SHALL IN NO EVENT BE L...

Отзывы: