30
Rev. 1.0
11/28/2017
STF-D/IP Hardware Manual
400-820-9661
5.5
Numbering System
5.6 Ordering Information
Model
Current
Voltage
Ethernet
Modbus/TCP
EtherNet/IP
Q Program
STF03-D
0.1 - 3.0 A
12 - 48 VDC
√
√
√
STF05-D
0.1 - 5.0 A
24 - 48 VDC
√
√
√
STF06-D
0.1 - 6.0 A
12 - 48 VDC
√
√
√
STF10-D
0.1 - 10.0 A
24 - 70 VDC
√
√
√
STF03-IP
0.1 - 3.0 A
12 - 48 VDC
√
√
√
STF05-IP
0.1 - 5.0 A
24 - 48 VDC
√
√
√
STF06-IP
0.1 - 6.0 A
12 - 48 VDC
√
√
√
STF10-IP
0.1 - 10.0 A
24 - 70 VDC
√
√
√
5.7 Alarm Code
Code
Error
solid green
no alarm,motor disabled
flashing green
no alarm,motor enabled
1 red, 2 green
move while disabled
2 red, 1 green
CCW limit
2 red, 2 green
CW limit
3 red, 1 green
drive over temperature
3 red, 2 green
internal voltage bad
3 red, 3 green
blank Q segment
4 red, 1 green
over voltage
4 red, 2 green
under voltage
5 red, 1 green
over current
6 red, 1 green
open motor winding
7 red, 1 green
communication error
NOTE: Items in
bold italic
represent Drive Faults, which automatically disable the motor.
STF 05 - D
Output Current
03 = 3A(Peak)
05 = 5A(Peak)
06 = 6A(Peak)
10 = 10A(Peak)
Control Mode
D = Ethernet
IP = EtherNet/IP
STF Series