17
Rev. 1.0
11/28/2017
STF-D/IP Hardware Manual
400-820-9661
3.1 Digital Inputs
3.1.1 X1, X2, X3 and X4 Digital Inputs
X1, X2: optically isolated, differential, 5-24VDC for high level voltage, minimum pulse width 250ns,
maximum pulse frequency 2MHz
X3, X4: optically isolated, differential, 5-24VDC for high level voltage, minimum pulse width
100
μ
s,maximum pulse frequency 5KHz
X1 can be used as general purpose input.
X2 can be used as general purpose input.
X3 can be used as CW limit input or general purpose input.
X4 can be used as CCW limit input or general purpose input.
Please use STF Con
fi
gurator software for X1,X2,X3 and X4 function con
fi
guration.
Following graphs shows some common connection methods for the inputs:
STF
Drive
Switch or Relay
(closed = logic Low)
X1/2/3/4-
X1/2/3/4+
-
+
5-24
VDC
Power
Supply
STF
Drive
NPN
Output
X1/2/3/4-
X1/2/3/4+
output
+
–
5-24
VDC
Power
Supply
-
+
STF
Drive
PNP
Output
X1/2/3/4+
output
+
–
X1/2/3/4-
5-24
VDC
Power
Supply
-
+
Connecting the inputs to a Switch or Relay
Connecting the inputs to a NPN type output
Connecting the inputs to a PNP type output