background image

Generalities 

ISA 1 

Rev. -, April 2019 

1

 

Generalities 

Compliance with these operating instructions is required for safe use and smooth opera-

tion of the sliding system drive. Only persons who have read and understood these operat-

ing instructions are allowed to work with and on the sliding system drive. 

2

 

Safety 

2.1

 

Intended use 

The sliding system drive is intended for stationary mounting on sliding systems. The sliding 

system drive may only be used for safety functions if it is integrated into a higher-level 

safety system. The sliding system drive may only be used indoors and within the value 

range defined in the performance data. 
Any other use than that described is not considered the intended use. The manufacturer 

shall not be held responsible for any personal injury or damage to property resulting from 

improper use. 

2.2

 

Target group 

These operating instructions are intended for the qualified personnel of the manufacturers 

of motor-operated sliding systems. 

2.3

 

Safety regulations 

The sliding system drive has been built on the basis of applicable regulations, laws and 

standards and, thus, corresponds to the technical state of the art. During operation, how-

ever, residual risks may arise or impairments of the equipment may occur.  
The safety regulations and warnings in these operating instructions must be complied with 

to prevent any possible residual risks. 

 

2.3.1

 

Generalities 

 

These operating instructions must have been read and understood prior to mounting, 

commissioning, and utilisation of the sliding system drive. 

 

Comply with the general and national safety and accident prevention regulations. 

 

Keep these operating instructions during the life-cycle of the sliding system drive and 

pass them on to subsequent users. 

 

Disconnect the sliding system drive from the power supply prior to any work. 

 

Содержание ISA1 Series

Страница 1: ...T MOVES YOUR WORLD INSTRUCTION MANUAL INTELLIGENT SLIDING SYSTEM DRIVES ISA1 SERIES THE INTELLIGENT SLIDING SYSTEM DRIVE ISA1 ENSURES COMPACT AND POWERFUL BUILDING AUTOMATION IN PERFECTION Rev April 2...

Страница 2: ...ting from improper use 2 2 Target group These operating instructions are intended for the qualified personnel of the manufacturers of motor operated sliding systems 2 3 Safety regulations The sliding...

Страница 3: ...carried out by qualified electricians or by instructed persons under the direction and supervision of a qualified electrician 2 4 Safety devices Depending on the use intended the requirements for saf...

Страница 4: ...2 DIP switch for addressing 6 Operating mode selector switch 3 Servomotor 7 Mains connection 4 Gearbox with pinion shaft 8 Communication ports to other drives 3 1 Structure of the sliding system drive...

Страница 5: ...aft transmits a torque to the driving element of the sliding system The trans mission can take place e g to a toothed belt drive via a toothed pulley optional 4 Mounting 4 1 Scope of delivery Fig 3 Sc...

Страница 6: ...ed pulley reaches the toothed belt drive on the sliding system The sliding system drive can be fitted to the frame of the sliding system via threaded holes in the base plate or via threaded holes in t...

Страница 7: ...ided by the customer in deenergised condition The inputs must be pulled to GND via switching contacts The outputs are designed as pull up resistor inversion at the output The following table shall app...

Страница 8: ...the wire into the orifice Pull out the screwdriver The wire must be firmly clamped in the plug connector Repeat the procedure for all the wires 4 4 Setting the addresses The addresses are set via the...

Страница 9: ...6 represents the bus termination resistor Example A sliding system block with four sliding elements and four sliding system drives is mounted Set the address switch 1 in the DIP switch of the first s...

Страница 10: ...t provided by the customer to the connections I O 1 Fig 9 1 and I O 2 Fig 9 2 Please contact Moog in the event that parameter values have to be set which deviate from the standard values For the stand...

Страница 11: ...ally set the switches 5 6 to ON Connect all mains connections Fig 10 3 to the power supply Perform a teach in run 5 3 Adapting parameter values The sliding system drive is delivered either with defaul...

Страница 12: ...irst 30 cm safetyTime minimum duration the higher prio motor has to move first 5 s mainTimeout main timeout for waiting on slaves 60 s 5 4 Teach in run The teach in run must be started during commissi...

Страница 13: ...m drive can be operated 8000 h in continuous operation without any maintenance or care After this period of maintenance free continuous operation or when the sliding system drive is no longer operativ...

Страница 14: ...manually by pressing any button N The system stops the error text internal Error is displayed Error counter logging CAN error Trigger a manual system restart by pressing any button Connect SMI and re...

Страница 15: ...ops and is ready for reference run The error text internal Error is displayed Power failure Start reference run by pressing the reference teach in push button K The system stops The error text interna...

Страница 16: ...istered trademark of Moog Inc and its subsidiaries All trademarks as indicated herein are the property of Moog Inc and its subsidiaries 2019 Moog Inc All rights reserved All changes are reserved Moog...

Отзывы: