Commissioning
ISA 1
10
Rev. -, April 2019
5
Commissioning
The following description applies for the commissioning both after first mounting and
after the installation of a replacement device.
5.1
Single connection
WARNING
Voltage.
While the housing is open, there is a risk of electrical shock.
Do not open the housing.
Do not put the sliding system drive into operation without housing.
Connect the communication cables from the operating element provided by the
customer to the connections I/O 1 (Fig.
/2).
Please contact Moog in the event that parameter values have to be set which deviate
from the standard values. For the standard parameter values refer to section
Set address on the DIP switch to A1, and switches 5 + 6 to "ON".
Connect mains cable to mains connection (Fig.
/4) and connect with power supply.
Perform a teach-in run.
The RJ45 communication ports (Fig.
9/5) are not assigned in the case of single
connection.
1 Connection I/O 1
2 Connection I/O 2
3 RJ45 communication port OUT
4 Mains connection
5 RJ45 communication port IN
Fig. 9
Single connection