MSD Servo Drive AC-AC Operation Manual
moog
49
Id. no.: CA65642-001 Date: 03/2012
[
Commissioning
]
4.4.3 Parameter menu (PA)
In the parameter menu the following functions are available:
•
Reset the device setting to the factory setting
•
Dataset handling with the MMC-card
NOTES:
•
MMC operation is only possible if the power stage is
not
active.
•
Accessing attempts to the MMC can take up to 2 minutes. Both decimal
points are flashing during this time.
Menu level Param-
eter
Value
range
Meaning
Explanation
1
2
PA
Pd
-
00..99
Parameter
download
*)
100 datasets (0..99) can be read from
path: \PARA\TRANSFER\PDSxx.dmd
(xx = 00.99) from the MMC.
Pu
-
00..99
Parameter
upload
*)
100 datasets (0..99) can be saved to the
MMC in the directory
\PARA\TRANSFER\
PDSxx.dmd
. The directory is automati-
cally created. Existing datasets can be
overwritten.
Pr
-
-
Parameter reset
To reset device settings to factory setting
Pc
-
-
Parameter clear
To delete all datasets on the MMC-card.
*) MMC operation is only possible if the power stage is not active. Accessing attempts to the MMC can take up to 2 minutes.
Table 4.6 Parameter menu
Error numbers
A failed user action is indicated with an error message. The message consists of the
alternating display of “Er” and the error number.
NOTE:
The error messages within the scope of user input must not be
mistaken as drive error messages. Detailed information concerning the
error codes and error management can be found in the “MSD Servo Drive
Application Manual”.
Error number
Meaning
00
File System No Error
01
File System Any file system error
02
File System command rejected
03
File System function parameter invalid
04
File System create file error
05
File System open file error
06
MMC create directory failed
07
MMC mounting error
08
MMC unmounting error
09
MMC using not allowed with current technology option card
10
MMC error uninstall X12 card
11
MMC not inserted
12
MMC mounting, create node
13
MMC not supported by hardware (not NSP 257)
14
MMC device in control enabled
15
MMC load parameter dataset to device failed
16
MMC save parameter dataset failed
17
Parameter reset to factory settings failed
18
Parameter write access failed
19
Save parameter data set non volatile failed
20
Not all parameters written
21
Error while reset to factory settings
Table 4.7 Error numbers