8. TOOLS AND EQUIPMENT
a.
5mm Allen wrench
b.
3mm Allen wrench
c.
Large blade screwdriver
d.
Small screwdriver
e.
Scriber or small screwdriver
f.
Clean grease (mounting and insertion of O-rings)
The D661 Series valves require tools for installation, set up, null
adjustment and filter replacement.
➢
Installation of the valve
➢
Mounting of the D661 Series requires 5mm Allen wrench
➢
Null adjust of the valve at set up
➢
Large blade screwdriver to remove the cover screw
(see cut-away diagram on page 1)
➢
Small screwdriver for zero setting on internal potentiometer
Replacement Parts
Part Description
D661-
Qty.
Part Number
O-Ring, ports P, T, A, B, (T
2
)
all
5
42082-004
O-Ring, ports X&Y
all
2
42082-011
Replaceable Filter Disk
P...A/B
1
A67999 200
Replaceable Filter Disk
G, S, H & P...F/G
1
A67999 100
O-Ring, behind filter disk
all
1
A25163 013 015
O-Ring, for filter cover
P...A/B
1
B97009 080
O-Ring, for filter cover
G, S, H
1
A25163 017 020
Allen Setscrew, ports X & Y
G & P
2
66166 040 006
Screw plug, port X
S & H
1
66098 040 006
Seal, port X
S & H
1
A25528 040
Accessories
(not part of the valve delivery)
Part Description
D661-
Qty.
Part Number
Mating Connector,
waterproof, protection IP65
6+PE-pole
DIN 43563
B97007 061
11+PE-pole
DIN 43651
B97024 111
11+1-pole (Bayonet)
MIL C-26482/14-12
B97027 012
6-pole
MIL C-5015/14S-6
A26201 004
12-pole (Bayonet)
MIL C-26482/14-12
B97027 012
Mounting Manifolds
See special data sheet
Mounting Bolts
M6x60 DIN 912-10.9
...G and ...P
4
A03665-060-060
M6x55 DIN 912-10.9
...H and ...S
4
A03665-060-055
Flushing Plate
B67728-001
Flushing Plate
B67728-002
Flushing Plate
B67728-003
12
7. ELECTRICAL NULL ADJUSTMENT
The hydraulic null of the valve is preset at the factory with a tolerance
of
±
2% of rated signal. If necessary, this null can be readjusted by the user of
the valve.
a.
Observe operating instructions for the machine/plant.
Valves with +4 to +20 mA command signal: Do not adjust valve
null! Contact machine/plant manufacturer.
b.
Procedure: Remove the command signal to the valve only by
disconnecting command signal lead at the cabinet.
Do not remove valve mating connector!
Remove cover screw on electronics housing to access the null adjust
potentiometer. Use a small screwdriver (blade width 2.5 mm) to turn
the potentiometer screw either clockwise or counterclockwise. Usually
it will not be necessary to turn the screw more than 2 turns in either
direction (
±
1 turn is equivalent to
±
15% null shift).
c.
While adjusting, watch the actuator (motor) motion to find the null
position. With overlapped valves, turn the null adjust screw carefully in
both directions to just start motion and then back into deadzone
midposition between those two screw positions.
d.
After proper null adjustment, reconnect the command signal lead and
install protective cover screw again.
DANGER