Response Packet Codes to Motor Commands
Response
Code
Event for
update
Response
Data Value
Response Description
Smart
Motor
Command(s)
decimal, hex
161, xA1
N/A
0
(Reserved)
162, xA2
cyclic
<value>=
velocity
RVA
163, xA3
cyclic
<value>=
buffered maximum velocity
RVT
164, xA4
cyclic
<value>=
legacy status word
(n/a)
165, xA5
cyclic
<value>=
value of negative software limit
RSLN
166, xA6
cyclic
<value>=
value of positive software limit
RSLP
167, xA7
N/A
0
(Reserved)
168, xA8
cyclic
<value>= Inputs 0-7, 16-bit value, right justified
RIN(W,0)
169, xA9
N/A
0
(Reserved)
170, xAA
cyclic
<value>=
status word 0
RW(0)
171, xAB
cyclic
<value>=
status word 1
RW(1)
172, xAC
cyclic
<value>=
status word 2
RW(2)
173, xAD
cyclic
<value>=
status word 3
RW(3)
174, xAE
cyclic
<value>=
status word 4
RW(4)
175, xAF
cyclic
<value>=
status word 5
RW(5)
176, xB0
cyclic
<value>=
status word 6
RW(6)
177, xB1
cyclic
<value>=
status word 7
RW(7)
178, xB2
cyclic
<value>=
status word 8
RW(8)
179, xB3
cyclic
<value>=
status word 9
RW(9)
180-181,
xB4-xB5
N/A
0
(Reserved)
182, xB6
cyclic
<value>=
user bits 0-15 (status word 12)
RW(12)
183, xB7
cyclic
<value>=
user bits 16-31 (status word 13)
RW(13)
184-185,
xB8-xB9
N/A
0
(Reserved)
186, xBA
cyclic
<value>=
I/O 0-7 (status word 16)
RW(16)
187-199,
xBB-xC7
N/A
0
(Reserved)
200, xC8
cyclic
<value>=
u8VarIndexSet
201, xC9
cyclic
<value>=
u8VarIndexSetActual
202, xCA
cyclic
<value>=
u8VarLenSet
203, xCB
cyclic
<value>=
u8ArrIndexSet
204, xCC
cyclic
<value>=
u8ArrIndexSetActual
205, xCD
cyclic
<value>=
u8ArrLenSet
206, xCE
cyclic
<value>=
u8AutoIncSet
207, xCF
cyclic
<value>=
u8VarIndexGet
208, xD0
cyclic
<value>=
u8VarIndexGetActual
209, xD1
cyclic
<value>=
u8VarLenGet
210, xD2
cyclic
<value>=
u8ArrIndexGet
211, xD3
cyclic
<value>=
u8ArrIndexGetActual
212, xD4
cyclic
<value>=
u8ArrLenGet