PROFINET Communication Example
PROFINET Communication Example
The following example illustrates PROFINET communications. It sends commands from a PLC
over PROFINET to cause the SmartMotor to continually report its changing clock value to the
PLC. The value is displayed by the PLC registers containing the PROFINET data received from
the motor. It changes as the updated clock value is received.
To create a PROFINET connection to the SmartMotor:
1. Install the SMI software. For more details, see the
Moog Animatics Class 6
SmartMotor™ Installation & Startup Guide
.
2. Connect control power to the 12-pin connector.
a. Pin 11 is 24 Volt control power.
b. Pin 12 is Ground or 24 Volt low.
3. Connect a USB cable from the PC to the USB connector on the SmartMotor. Refer to the
following figure.
USB Connection from PC to SmartMotor
Moog Animatics Class 6 PROFINET Guide Rev. D
Page 25 of 76