EN -23-
After ignition, visually check the flames. If you see a yellow tip, lifted or unstable flames,
turn the gas flow off, then check the assembly of burner caps and crowns once they
have cooled. Make sure there in no liquid in the burner cups. If the burner flames go out
accidently, turn the burners off, ventilate the kitchen with fresh air and wait at least 90
seconds before attempting re-ignition.
To turn the hob burners off, Turn the hob burner knob clockwise so that the hob burner
knob shows the „0‟ position or the marker on the hob burner knob points upwards.
Your hob has burners of different diameters. You will find that the most economical way
of using gas is to choose the correct size gas burner for your cooking pan size and to
bring the flame to the minimum position once boiling point is reached. We recommend
that you always cover your cooking pan.
To obtain maximum performance from the main burners, we suggest you use pots with
the following flat bottom diameters.Using pots smaller than the minimum dimensions
shown below will cause energy loss.
Rapid / Wok Burner
22-26 cm
Semi-rapid Burner
14-22 cm
Auxiliary Burner
12-18 cm
OFF position
MAX position
MIN. position
MODULATE
Cap
Crown
Spark
plug
Burner
cup