LDVPV58 Linear Power Vent

Introduction  ................................................................................ 2
Installation
 

Venting Installation ....................................................3 - 4

 

Power Vent - Horizontal Vent ............................. 3

 

Power Vent - Horizontal / Downward Vent ......... 3

 

Power Vent - Vertical Vent ................................. 4

 

Power Vent Installation................................................... 5

 

Wiring Instructions.......................................................6-7

Warranty ..................................................................................... 8
Termination Locations ................................................................. 9

General Information

This installation guide covers installation of the 

LDVPV58

 Linear Power 

Vent System only. This system is designed to allow installation of gas 
fireplaces that 

cannot be done

 with a standard Direct Vent gas 

fireplace installation.
Specifications and instructions pertaining to your chosen fireplace must 
be followed.  Please read this Installation Operation and Maintenance 
Instructions carefully before operating this equipment.
 
 

Standard Series (5"/8" dia.) Termination System:

 

LDVPV58 - Linear Power Vent System

 

Pre/Post Purge Control Box (ECA045PC, ECA062PV)

 
 

Power Cord Harnesses:

 

EPVH-10  10 foot power cord and harness

 

EPVH-20  20 foot power cord and harness

 

EPVH-40  40 foot power cord and harness

 

EPVH-60  60 foot power cord and harness

 

EPVH-80  80 foot power cord and harness

Selecting and Installing the Power Vent

The Linear Power Vent System must only be used with a Montigo Direct 
Vent Fireplace. When selecting  Venting components for use with this 
Linear Power Vent System, take into consideration the various require-
ments required for the vent installation section of the Model's manual: 

Models Must Be Equipped with Electronic Ignition 

Only models equipped with an electronic ignition system may be installed 
with the Linear Power Vent System.  The absence of a standing pilot in 
this system, allows for greater flexibility on venting requirements. For 
example  downward vertical vent runs are possible with an electronic 
ignition system, as outlined in the Venting Section.

Table Of Contents

Introduction

Before You Begin

 

Minimum clearances of 1" from vent to all combustible materials 
must be maintained. 

 

The 

LDVPV58

 must only  be installed with Montigo venting 

components.  The  

LDVPV58

 may be used with any of the 

available Montigo terminations.

 

Installation of the LDVPV58 must comply with this manual, and 
be completed by a qualified professional.

 

Ensure the pipe ends male to female slide in a minimum of 1 
1/2'' overlap

 

Connect all vent sections using a minimum of 3 sheet metal 
screws on the outer pipe flue.

 

Plan the layout of the installation's venting run before starting 
the installation.

 

The MAXIMUM total allowable length; Refer to Linear Power 
Vent Installation.

 

Minimum length of straight pipe between the Fireplace and the 
Power Vent is:  2 feet

 

Access / Service Panel, must maintain 2" clearance. If  2" 
clearance is not possible Minimum 30% free air must be supplied.

 

Disconnect the power supply when installing and/or servicing 
the fireplace or the power vent system.

CAUTION

:

When cold air enters the warmer building interior, primarily at the 
air intake end, condensation may occur on the exterior of the flex 
pipe.  To limit this condensation, install insulation over the last 
twenty feet of flex pipe. Also, by sloping the last 20'-0" feet of flex 
pipe downward toward the exterior of the building, elimination of 
most of the condensation problems should occur. Ensure the ter-
mination is securely fastened, and sealed to the flex pipe. Fasten 
the termination to exterior of the building with water tight sealant 
and the appropriate fasteners.

Specifications:
Dimensions: 34 7/8"L x 18 1/2"W. x 11 1/2"D.
Vent Size: (IN) 5"/8"  (Out) 5"/8"
Motors: 1/10HP each, x 1.8A each (2) motors
Sound Level:         dba
Weight: 60Lbs.

Содержание LDVPV58

Страница 1: ...Safety Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance Safety Notice Venting Components and the Power Vent System can be extremely ho...

Страница 2: ...nts For example downward vertical vent runs are possible with an electronic ignition system as outlined in the Venting Section Table Of Contents Introduction Before You Begin Minimum clearances of 1 f...

Страница 3: ...m for the LDVPV58 Linear Power Venter WARNING Montigo will not be held responsible for any wa ter damage that may occur from not installing the equipment as specified by this document Linear Power Ven...

Страница 4: ...ent must be two feet 2 0 Maximum allowable vent run must be reduced by Ten feet 10 0 for every 90 elbow added Deduct ten feet 10 0 of vent length for every one foot 1 0 of vent run traveling in a down...

Страница 5: ...framed at 18 X 18 To enclose the service access panel at less than 1 a minimum 30 free air must be supplied at all times 2 Plug the power chord into the available slot in the linear power vent 3 Secur...

Страница 6: ...When installing the wiring it must never run above the vent run and it must be at least 1 clear of all venting 1 Clearance BLACK WHITE WHITE BLACK BLACK WHITE GREEN VARIABLE SPEED COMFORT FANS Lights...

Страница 7: ...G OPTIONAL STEPPER MOTOR E 6 10 6 W W GREEN BLACK POWER VENT AIR SWITCH ELLOW ELLOW ELLOW ELLOW BLACK GREEN RED BROWN WHITE CPI IPI SWITCH WHITE SW1 Figure 8a Wiring Clearances Wiring Installation Con...

Страница 8: ...rmal use The Gas Appliances are designed to burn gas only Burning conventional fireplace fuels such as wood coal or any other solid fuel will cause damage to the Gas Appliance will produce excessive t...

Страница 9: ...ocations PTO4 PV TMHIN 36 TMHIN 40 40 1016 14 1 2 367 37 3 4 960 6 1 2 166 2 1 4 57 8 3 4 223 1 4 7 Minimum combustible clearances Termination 12 1 4 310 1 4 7 Minimum combustible clearances Minimum C...

Страница 10: ...Canadian Heating Products Inc Langley BC V4W 4A1 Montigo Del Ray Corp Ferndale WA 98248 XG0752 160902...

Отзывы: