Page 30
L42DF* Indoor Gas Fireplace
XG0181 -
150204
Maintenance
Troubleshooting
SIT Nova 820:
The following is a troubleshooting chart of possible problems:
PROBLEM
SOLUTION
Noisy Pilot Flame
Locate pilot adjustment screw on gas
control valve. Flame is decreased by
turning adjustment screw clockwise.
Pilot won’t ignite
Disconnect remote wires and try to
light pilot. If pilot now works, remote
connections are faulty. Check wiring
diagram
figure 29
.
Main burner will not ignite
1. Check wiring (see
figure 29
).
2. Check wall switch for proper
connection.
If your fireplace still does not operate correctly, consult your local Montigo dealer.
All service and repairs should be performed by a qualified Technician.
All spare parts, optional fans, and optional trim finishes are available from your local Montigo dealer.
SIT Proflame 2:
The following is a troubleshooting chart of possible problems:
PROBLEM
SOLUTION
Pilot Igniter won't spark
1. Check the MAIN ON-OFF switch
(typically located below the valve cover)
and turn ON
2. Ensure main power is ON or new
batteries are installed in the remote
control and backup battery pack (if
available).
3. Check the 3.15A fuse in the control
box and replace if necessary
Pilot Igniter sparking, but
Pilot burner will not light
1. Verify the Inlet and Manifold Gas
Pressure are within acceptable limits
2. Check all connections to gas valve
3. Check connection to stepper motor
(if available)
Pilot lights , but Main burner
will not Light
1. Check and verify all wiring connections
as per the wiring diagram.
2 . Verify the inlet and Manifold Pressure
are within acceptable limits
Pilot lights , but Main burner
will not Light and igniter
continues to spark
1. Check the Pilot Flame Sensor Rod
and clean with steel wool or similar.
2 . Check the Pilot hood and clean with
steel wool if dirty.
3. Adjust pilot flame using the pilot
adjustment screw if the pilot flame is
too long or too short (Flame should
fully engulf the sensor rod and must
be stable).
4. Check and make sure the ground
wire from the pilot is connected to the
fireplace body.
Fans not working
1. Ensure main power is ON (fireplace
may be operating on back up batteries).
2. Check the 3.15A fuse in the control
box and replace if necessary
SIT IPI Proflame 2 - Replacement Parts List
L42DF
NG Gas Valve (Hi Low)
RGC3044
LP Gas Valve (Hi Low)
RGC3045
NG Gas Valve (with stepper motor)
RGC3033
LP Gas Valve (with stepper motor)
RGC3034
NG Pilot Assembly
RPA035
LP Pilot Assembly
RPA036
Ignitor Probe Assembly
RGC3075
Flame sensor rod assembly
RGC3076
Pilot Tubing
RPTA03
Door
RDTL42
Control Module
RGC3061
Proflame Transmitter
RGC3063
Replacement Screen
RSCP42