L42DF* Indoor Gas Fireplace

XG0181 -  

150204

Maintenance

Troubleshooting

 SIT Nova 820:

The following is a troubleshooting chart of possible problems:

PROBLEM

SOLUTION

Noisy Pilot Flame

Locate pilot adjustment screw on   gas 

control valve. Flame is decreased by 

turning adjustment screw clockwise.

Pilot won’t ignite

Disconnect remote wires and try to 

light pilot. If pilot now works, remote 

connections are faulty. Check wiring 

diagram 

figure 29

.

Main burner will not ignite

1. Check wiring (see 

figure 29

).

2. Check wall switch for proper 

connection.

If your fireplace still does not operate correctly, consult your local Montigo dealer.

All service and repairs should be performed by a qualified Technician.

All spare parts, optional fans, and optional trim finishes are available from your local Montigo dealer.

SIT Proflame 2:

The following is a troubleshooting chart of possible problems:

PROBLEM

SOLUTION

Pilot Igniter won't  spark

1. Check the MAIN ON-OFF switch  

(typically located below the valve cover) 

and turn ON

2.  Ensure main power is ON or new 

batteries  are  installed  in  the  remote 

control  and  backup  battery  pack  (if 

available).

3. Check the 3.15A fuse in the control 

box and replace if necessary

Pilot  Igniter  sparking,  but 

Pilot burner will not light

1. Verify the Inlet and Manifold Gas 

Pressure are within acceptable limits

2. Check all connections to gas valve
3. Check connection to stepper motor 

(if available)

Pilot lights , but Main burner 

will not Light

1. Check and verify all wiring  connections 

as per the wiring diagram.
2 . Verify the inlet and Manifold Pressure 

are within acceptable limits

Pilot lights , but Main burner 

will not Light and igniter 

continues to spark

1.  Check the Pilot Flame Sensor Rod 

and clean with steel wool or similar.
2 . Check the Pilot hood and clean with 

steel wool if dirty.

3.  Adjust  pilot  flame  using  the  pilot 

adjustment screw if the pilot flame is 

too long or too short (Flame should 

fully engulf the sensor rod and must 

be stable).

4. Check and make sure the ground 

wire from the pilot is connected to the 

fireplace body.

Fans not working

1. Ensure main power is ON (fireplace 

may be operating on back up batteries).

2. Check the 3.15A fuse in the control 

box and replace if necessary

SIT IPI Proflame 2 - Replacement Parts List

                                                                        

L42DF

NG Gas Valve (Hi Low)

RGC3044

LP Gas Valve (Hi Low)

RGC3045

NG Gas Valve (with stepper motor)

RGC3033

LP Gas Valve (with stepper motor)

RGC3034

NG Pilot Assembly

RPA035

LP Pilot Assembly

RPA036

Ignitor Probe Assembly

RGC3075

Flame sensor rod assembly

RGC3076

Pilot Tubing

RPTA03

Door

RDTL42

Control Module

RGC3061

Proflame Transmitter

RGC3063

Replacement Screen

RSCP42

Содержание L42DF series

Страница 1: ...e Toxic Flammable materials Corrosive Fork lift trucks Danger overhead crane Explosion risk Oxidising Danger of death Biohazard Laser Radiation Danger of entrapment Hot surface General Warning Blank G...

Страница 2: ...t Vent Termination PVTK 1 11 Section 3 2 1 Venting Layout 11 Section 3 3 1 Venting Layout Wall mounted termination 14 Section 3 3 2 Venting Components 18 Section 3 3 3 Heat Shields 19 Section 4 Wiring...

Страница 3: ...being installed This installation operation and maintenance manual is applicable to the modelsdescribedinthetable Refertoyourratingplatetoverifyincluded options Throughout this instruction guide inst...

Страница 4: ...must conform to the local codes or in the absence of local codes to the current version of National Fuel Gas Code ANSI Z223 1 NFPA 54 Electrical Installations must conform to the local codes or in th...

Страница 5: ...llation Rating Plate Sample Figure A Rating Plate for IPI eletronic ignition LB1223 V5 1 SIT IPI with screen DEC06 2014 Teklynx LabelView Demo Figure B Rating Plate for standing pilot SIT LBL1205 V6 1...

Страница 6: ...replace may be installed in any location that maintains properclearancestoairconditioningducts electricalwiringandplumbing Safety as well as efficiency of operation should be considered when selecting...

Страница 7: ...Framing for Rear Vent with shelf above the fireplace Note Straight through the wall rear vent available for Natural Gas only Figure4 CombustibleFramingforRearVent withshelfabovefireplace 2 Min 12 Max...

Страница 8: ...s ie cement board or equivalent This is recommended in applications where the facing materials will not adhere to the metal nailing flange 6 NOTE Clearance from top of fireplace to a ceiling within th...

Страница 9: ...arefastenedinplaceasshown TheseareinstalledwiththeWideflanges facing the center of the fireplace opening and the shallow flange toward inside of room These are also fastened with nails or screws flush...

Страница 10: ...go supplies a variety of direct venting and termination options The direct vent termination location MUST be selected such that it is the highest point in the venting assembly It should also be select...

Страница 11: ...mterminationpointis32 abovethefireplace NOTE if the maximum termination height is used the flame pattern may be affected TheVerticalterminationmustbeaminimum2 higherthanwhere the termination exits the...

Страница 12: ...Figure 11c Rear vent Roof mounted venting 1 90 bend Support ring Support plate 32 max MEXT Sections Termination 12 Max PVTK1 Note Imagesareshownwithoutscreensforclaritypurposes However your fireplace...

Страница 13: ...he BSR opening to 12 x 12 2 Secure the BSR Frame to the exterior sheathing of the structure 3 Fasten the termination to the BSR Frame using a minimum of 4 screws 1 Frame the MOSR opening to 12 x 12 2...

Страница 14: ...n with one 90 bend The vent run must comply with Venting Graph forTop vent wall mounted terminations Figure 14 Figure 14b Top Vented wall mounted Multi elbow installation See Venting Graph for Top ven...

Страница 15: ...ted wallmountedRetractedMulti elbowinstallation See Venting Graph for Top vent wall mounted terminations Figure 14 Heat Shield 96 Min 120 Max Note Imagesareshownwithoutscreensforclaritypurposes Howeve...

Страница 16: ...and attach to the termination 45 or less Corner Installation Use an PTO 4 termination and an PFL 1 or PFL 2 PFL 2 12 or 24 compressed length and a frame if appropriate Flex may be turned to obtain de...

Страница 17: ...area the installation is acceptable Example A Acceptable Installation If the vertical dimension from the hearth is 120 and the horizontal run to the wall flange of the vent termination is 138 this wo...

Страница 18: ...ng Envelope Engineer or Waterproofing Consultant for further recommendations Section 3 3 2 Venting Components The following components and associated Montigo part numbers for installation of a roof or...

Страница 19: ...ield MUST be used where the RHS8 Termination Figure 17 and 17a CANNOT be used Use the RHS101 where any of the dimensions are within the parameters shown figure 17a To install the RHS101 Slide the Inne...

Страница 20: ...djustment Screw Inlet Pressure Hi Lo Adjustment Knob Gas Control Knob Shown in Pilot position Figure 20 Wiring Diagram for SIT Nova 820 gas and pilot 1 5V AA type 1 5V AA type 1 5V AA type 1 5V AA typ...

Страница 21: ...r Vent Fireplaces Installing the remote On Off Wall Switch The L42DF gas valve may be connected to a wall switch Do NOT connect any external power to the remote switch The valve will generate its own...

Страница 22: ...valves approved for use by the state province or other governing body in which the fireplace is being installed Section 5 3 GAS CONNECTION See Figure 23 for location of gas line access Flexible gas co...

Страница 23: ...aces which are hot fuel and energy efficient Please be aware temperatures over the mantel will rise above normal room temperature and walls above fireplace may be hot to touch Side wall clearances are...

Страница 24: ...e Screens Grasp each top outer corner of the screen with your thumb and fingerandpulltowardsyourself WhentheupperScreenStudsare free liftthescreenatananglefromthelowerslotsfromwhichthe Screen Bottom T...

Страница 25: ...atch Hook Door Latch Slot Hand hold Locate Door Buckle Tool Figure 26b Door buckle Tool Step 4 Firmly grasp hand hold end of Door buckle tool and place the machined end in the slot under door frame as...

Страница 26: ...pleted firestone installation Second Gen burner shown Note DO NOT place ANY firestones on top of the burners or pilot Figure 27a Operating gas fireplace with firestones surrounding burner tray Second...

Страница 27: ...b cannot be turned from PILOT to OFF unless knob is pushed in slightly Do not force Standing Continuous Pilot Ignition SIT NOVA 820 with American Flame Electronic Ignition For Your Safety READ BEFORE...

Страница 28: ...to the next step 6 Turn fireplace ON using wall switch or remote control 7 If the Fireplace does not light the System will cycle through two trials one minute audible clicking thirty seconds of silen...

Страница 29: ...eglass cleaners One of the most effective products is Kel Kem Silicone seals on inner door during initial firing will off gas leaving a visual deposit of a white substance on combustion chamber walls...

Страница 30: ...nd turn ON 2 Ensure main power is ON or new batteries are installed in the remote control and backup battery pack if available 3 Check the 3 15A fuse in the control box and replace if necessary Pilot...

Страница 31: ...1 Piezo Ignitor PIEZO Pilot Tubing RPTA03 Door RDTL42 Replacement Screen RSCP42 SIT IPI Proflame 2 Replacement Parts List L42DF NG Gas Valve Hi Low RGC3044 LP Gas Valve Hi Low RGC3045 NG Gas Valve wit...

Страница 32: ...ance 100 000 BTU H 30 KW 12 inches 12 inches M clearance to forced air supply inlet 6 feet 3 feet above air inlet N clearance above paved sidewalk or paved driveway located on public property 7 feet 7...

Страница 33: ...anies 2 The Montigo Gas Appliance must be subjected to normal use The Gas Appliances are designed to burn gas only Burning conventional fireplace fuels such as wood coal or any other solid fuel will c...

Страница 34: ...of eight 8 feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one ha...

Страница 35: ...Page 35 L42DF Indoor Gas Fireplace XG0181 150204 Notes Notes...

Страница 36: ...XG0181 150204 L42DF Residential Gas Fireplace...

Отзывы: