L42DF* Indoor Gas Fireplace

XG0181 -  

150204

Installation

A - Termination

PTO4       (3" Length)

PTO4F     (3" Length)

PVTK1SS

B - Frame Kits

MSR          (Stucco Frame)

MOSR       (Stucco Frame)

BSR-4       (4" Brick Frame)

BSR-6       (6" Brick Frame)

C - Flex Sections

PFL - 1      (12" f/f Section)

PFL - 18    (18" f/f Section)

PFL - 2      (24" f/f Section)

PFL - 3      (36" f/f Section)

PFL - 4      (48" f/f Section)

PFL - 6      (72" f/f Section)

D - Rigid Sections

PXT - 5      (5" f/f Section)

PXT - 10    (10" f/f Section)

PXT - 20   (20" f/f Section)

PEXT - 1   (12" f/m Section)

PEXT - 2   (24" f/m Section)

PEXT - 3   (36" f/m Section)

PEXT - 4   (48" f/m Section)

PEXT - 6   (72" f/m Section)

E - Elbows

PEL-90MM  (m/m 90

º

 Elbow)

PEL-90FF    ( f/f 90

º

 Elbow)

PEL-90FM   ( f/m 90

º

 Elbow)

PEL-45FM   ( f/m 45

º

 Elbow)

F - Support Ring & Plate PSPXT-8
G - Firestop

FS-8

H - Roof Flashing

PRF-7       (1/12 - 7/12 pt.)

PRF-12     (7/12 - 12/12 pt.)

I - Heat Shield 

RHS101

J - Heat Guard 

MTKOG

Connection and installation of the vent components should 

adhere to the following guidelines:

 

„

Montigo recommends the use of a flex section for the final pipe 

connected directly to the fireplace offering greater flexibility of 

installation and absorption of movement. 

 

„

Firestops must be installed as required by National & local codes.

 

„

Montigo recommends that all exterior corners and joints be sealed 

with exterior caulking. However, we encourage you to consult 

your Building Envelope Engineer or Waterproofing Consultant 

for further recommendations.

Section 3-3-2:  Venting Components

The following components and associated Montigo part numbers for 

installation of a roof or wall mounted termination.  

Use only Montigo 

Vent Components. 

 Use of non-Montigo parts will 

VOID

 the warranty 

and may impede operation of the fireplace.

 

„

Use any combination of rigid and flex pipe as required and in 

any orientation (Male connectors can face in any direction).

 

„

Flex sections may be stretched up to 50% of their total length 

(e.g. a 24” section maybe stretched to 36”).

 

„

Connect all vent sections using a minimum of three sheet metal 

screws on the outer pipe flue.

 

„

Ensure the pipe ends male to female slide in a minimum of 1 

1/2” of overlap.

 

„

Ensure all horizontal runs are supported with a minimum of 3 

supports per 10’ of venting.

 

„

When hanging/ supporting venting, ensure that 1” clearance 

is maintained on sides and bottom of vent runs and 2” above 

horizontal vent runs to any combustible material.

 

„

Rigid pipe may be cut less than half way from the

 female end only.

 

„

Ensure when cutting sections of rigid pipe to maintain integrity 

of internal supports.

 

„

Place the springs, supplied with the pipe kit, between the outer 

and inner pipes to keep the pipes separate and avoid any 

possible hot spots.

Please refer to your building evelope engineer or waterproofing consultant fo

r

a review of 

ALL

 penetrations through exterior walls or the roof.  

IMPORTANT

Содержание L42DF series

Страница 1: ...e Toxic Flammable materials Corrosive Fork lift trucks Danger overhead crane Explosion risk Oxidising Danger of death Biohazard Laser Radiation Danger of entrapment Hot surface General Warning Blank G...

Страница 2: ...t Vent Termination PVTK 1 11 Section 3 2 1 Venting Layout 11 Section 3 3 1 Venting Layout Wall mounted termination 14 Section 3 3 2 Venting Components 18 Section 3 3 3 Heat Shields 19 Section 4 Wiring...

Страница 3: ...being installed This installation operation and maintenance manual is applicable to the modelsdescribedinthetable Refertoyourratingplatetoverifyincluded options Throughout this instruction guide inst...

Страница 4: ...must conform to the local codes or in the absence of local codes to the current version of National Fuel Gas Code ANSI Z223 1 NFPA 54 Electrical Installations must conform to the local codes or in th...

Страница 5: ...llation Rating Plate Sample Figure A Rating Plate for IPI eletronic ignition LB1223 V5 1 SIT IPI with screen DEC06 2014 Teklynx LabelView Demo Figure B Rating Plate for standing pilot SIT LBL1205 V6 1...

Страница 6: ...replace may be installed in any location that maintains properclearancestoairconditioningducts electricalwiringandplumbing Safety as well as efficiency of operation should be considered when selecting...

Страница 7: ...Framing for Rear Vent with shelf above the fireplace Note Straight through the wall rear vent available for Natural Gas only Figure4 CombustibleFramingforRearVent withshelfabovefireplace 2 Min 12 Max...

Страница 8: ...s ie cement board or equivalent This is recommended in applications where the facing materials will not adhere to the metal nailing flange 6 NOTE Clearance from top of fireplace to a ceiling within th...

Страница 9: ...arefastenedinplaceasshown TheseareinstalledwiththeWideflanges facing the center of the fireplace opening and the shallow flange toward inside of room These are also fastened with nails or screws flush...

Страница 10: ...go supplies a variety of direct venting and termination options The direct vent termination location MUST be selected such that it is the highest point in the venting assembly It should also be select...

Страница 11: ...mterminationpointis32 abovethefireplace NOTE if the maximum termination height is used the flame pattern may be affected TheVerticalterminationmustbeaminimum2 higherthanwhere the termination exits the...

Страница 12: ...Figure 11c Rear vent Roof mounted venting 1 90 bend Support ring Support plate 32 max MEXT Sections Termination 12 Max PVTK1 Note Imagesareshownwithoutscreensforclaritypurposes However your fireplace...

Страница 13: ...he BSR opening to 12 x 12 2 Secure the BSR Frame to the exterior sheathing of the structure 3 Fasten the termination to the BSR Frame using a minimum of 4 screws 1 Frame the MOSR opening to 12 x 12 2...

Страница 14: ...n with one 90 bend The vent run must comply with Venting Graph forTop vent wall mounted terminations Figure 14 Figure 14b Top Vented wall mounted Multi elbow installation See Venting Graph for Top ven...

Страница 15: ...ted wallmountedRetractedMulti elbowinstallation See Venting Graph for Top vent wall mounted terminations Figure 14 Heat Shield 96 Min 120 Max Note Imagesareshownwithoutscreensforclaritypurposes Howeve...

Страница 16: ...and attach to the termination 45 or less Corner Installation Use an PTO 4 termination and an PFL 1 or PFL 2 PFL 2 12 or 24 compressed length and a frame if appropriate Flex may be turned to obtain de...

Страница 17: ...area the installation is acceptable Example A Acceptable Installation If the vertical dimension from the hearth is 120 and the horizontal run to the wall flange of the vent termination is 138 this wo...

Страница 18: ...ng Envelope Engineer or Waterproofing Consultant for further recommendations Section 3 3 2 Venting Components The following components and associated Montigo part numbers for installation of a roof or...

Страница 19: ...ield MUST be used where the RHS8 Termination Figure 17 and 17a CANNOT be used Use the RHS101 where any of the dimensions are within the parameters shown figure 17a To install the RHS101 Slide the Inne...

Страница 20: ...djustment Screw Inlet Pressure Hi Lo Adjustment Knob Gas Control Knob Shown in Pilot position Figure 20 Wiring Diagram for SIT Nova 820 gas and pilot 1 5V AA type 1 5V AA type 1 5V AA type 1 5V AA typ...

Страница 21: ...r Vent Fireplaces Installing the remote On Off Wall Switch The L42DF gas valve may be connected to a wall switch Do NOT connect any external power to the remote switch The valve will generate its own...

Страница 22: ...valves approved for use by the state province or other governing body in which the fireplace is being installed Section 5 3 GAS CONNECTION See Figure 23 for location of gas line access Flexible gas co...

Страница 23: ...aces which are hot fuel and energy efficient Please be aware temperatures over the mantel will rise above normal room temperature and walls above fireplace may be hot to touch Side wall clearances are...

Страница 24: ...e Screens Grasp each top outer corner of the screen with your thumb and fingerandpulltowardsyourself WhentheupperScreenStudsare free liftthescreenatananglefromthelowerslotsfromwhichthe Screen Bottom T...

Страница 25: ...atch Hook Door Latch Slot Hand hold Locate Door Buckle Tool Figure 26b Door buckle Tool Step 4 Firmly grasp hand hold end of Door buckle tool and place the machined end in the slot under door frame as...

Страница 26: ...pleted firestone installation Second Gen burner shown Note DO NOT place ANY firestones on top of the burners or pilot Figure 27a Operating gas fireplace with firestones surrounding burner tray Second...

Страница 27: ...b cannot be turned from PILOT to OFF unless knob is pushed in slightly Do not force Standing Continuous Pilot Ignition SIT NOVA 820 with American Flame Electronic Ignition For Your Safety READ BEFORE...

Страница 28: ...to the next step 6 Turn fireplace ON using wall switch or remote control 7 If the Fireplace does not light the System will cycle through two trials one minute audible clicking thirty seconds of silen...

Страница 29: ...eglass cleaners One of the most effective products is Kel Kem Silicone seals on inner door during initial firing will off gas leaving a visual deposit of a white substance on combustion chamber walls...

Страница 30: ...nd turn ON 2 Ensure main power is ON or new batteries are installed in the remote control and backup battery pack if available 3 Check the 3 15A fuse in the control box and replace if necessary Pilot...

Страница 31: ...1 Piezo Ignitor PIEZO Pilot Tubing RPTA03 Door RDTL42 Replacement Screen RSCP42 SIT IPI Proflame 2 Replacement Parts List L42DF NG Gas Valve Hi Low RGC3044 LP Gas Valve Hi Low RGC3045 NG Gas Valve wit...

Страница 32: ...ance 100 000 BTU H 30 KW 12 inches 12 inches M clearance to forced air supply inlet 6 feet 3 feet above air inlet N clearance above paved sidewalk or paved driveway located on public property 7 feet 7...

Страница 33: ...anies 2 The Montigo Gas Appliance must be subjected to normal use The Gas Appliances are designed to burn gas only Burning conventional fireplace fuels such as wood coal or any other solid fuel will c...

Страница 34: ...of eight 8 feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one ha...

Страница 35: ...Page 35 L42DF Indoor Gas Fireplace XG0181 150204 Notes Notes...

Страница 36: ...XG0181 150204 L42DF Residential Gas Fireplace...

Отзывы: