Page 7
HWDF-Series Gas Fireplace
Part No. XG0190 - 071409
Installation
Figure 8a.
Flue cap installation for Rear Vented fireplace.
Figure 8b.
Flue collar installation for Rear Vented fireplace.
Important:
Natural Gas and Propane equipped models
may be installed using Top or Rear Vent applications.
5” Inner Flue Cap
8” Outer Flue Cap
5” Inner Flue Collar
8” Outer Flue Collar
Figure 7b.
Flue collar installation, Top Vented HW38DF fireplace.
5” Inner Flue Cap
8” Outer Flue Cap
5” Inner Flue Collar
8” Outer Flue Collar
Figure 8b.
Flue collar installation, Rear Vented L38DF fireplace.
Converting to Top Vent/ Rear Vent
HW38DF Top Vent
Use the following instructions to convert a
HW38DF
,
for Top Vent use:
1.
Install the 5" inner flue cap on the rear flue outlet and secure the
cap in place with five screws, as shown in figure 7a.
2.
Install the 8" outer flue cap on the rear flue outlet, and secure it
with five screws, as shown in figure 7a.
3.
Install the flue gasket material and flue cover plate on the rear vent
outlet . Fasten the plate with four screws, as illustrated below.
4.
Install the 5" inner flue collar and the 8" outer flue collar in place
on the top vent outlet using 5 screws, as illustrated below.
HW38DF Rear Vent
Use the following instructions to convert an
HW38DF,
for Rear Vent use:
1.
Install the 5" inner flue cap on the top flue outlet and secure the
cap in place with five screws, as shown in figure 8a.
2.
Install the 8" outer flue cap on the top flue outlet, and secure it
with five screws, as shown in figure 8a.
3.
Install the flue gasket material and flue cover plate on the top vent
outlet. Fasten the plate with four screws, as illustrated in figure 8b.
4.
Install the 5" inner flue collar and the 8" outer flue collar in place
on the rear vent outlet using 5 screws, as illustrated below.