Page 14
HW-Series Gas Fireplace
Part No. XG0190 - 071409
Installation
Mantels & Surrounds
NOTE:
National Canadian Gas Association mantel test requirements
are for fire hazard prevention to combustible materials.
New technology, to meet consumer and government demands for the
wise use of energy, has prompted us to manufacture many models of
fireplaces which are hot, fuel and energy efficient.
Please be aware; temperatures over the mantel will rise above normal
room temperature and walls above fireplace may be hot to touch.
Figure 25.
Combustible surrounds.
Wiring
Gas Control and Pilot Wiring
Honeywell (Q3450)
Pilot Assembly
Pilot Electrical
Harness Connector
Honeywell Gas
Control (SV9501M)
Gas Control
Connector
Fuse
Limit
Switch
Wall
Switch
Fan Plug
Receptacle
Junction Box
Junction Box Cover
White
Black
Green
40 VA
Transformer
115VAC
24VAC
Grnd Screw
Figure 26.
Wiring for the HW38-DF-I with Honeywell gas control and pilot.
Non-Combustible
Facing Material
Header
Drywall/
Sheetrock
6”
Wiring for the
optional
Fan Kit
All
HW38DF
fireplaces may be equipped with optional fan kits for
circulating heat into the living space.
Installations in Canada
which employ the fans must be electrically
grounded in accordance with
CSA C22.1
Canadian Electrical Code
Part 1 and/or Local Codes.
Installations in the USA
which employ the fans must be grounded in
accordance with local codes or, in the absence of local codes, with the
National Electrical Code,
ANSI/NFPA 70-1987.
For more information see the
Fan Kit Installation Guide
included with
the fan kit.
NOTE:
If any of the original wire supplied with the appliance is replaced, it
must be replaced with the same type, or its equivalent.
Figure 27a.
Wiring schematic for optional fans.
G
L2-WH
L1-BLK
p g
Quick Connect
lu to motor
5/1/60 Supply
G
L1 L2