The Warranty

The Companies warrants the Montigo Gas Appliance to be free from defects in materials and workmanship at the time of manufacture. On the Montigo, there is a 
ten-year warranty on the firebox and its components, a five-year warranty on the main burner and pilot burner, and a one-year warranty on the gas control valve 
and fibre logs. Glass, plated/painted finishes, and refractory lining are exempt.

Remedy And Exclusions

The coverage of this Warranty is limited to all components of the Gas Appliance manufactured by The Companies.
This Warranty only covers Montigo Gas Appliances installed in the United States or Canada.
If the components of the Gas Appliance covered by this Warranty are found to be defective within the time frame stated (see The Companies right of investigation 
outlined below). The Companies will, at its option, replace or repair defective components of the Gas Appliance manufactured by The Companies at no charge, 
and will also pay for reasonable labour costs incurred in replacing or repairing components. If repair or replacement is not commercially practical, The Companies 
will, at its option, refund the purchase price of the Montigo Gas Appliance. 
This Warranty covers only parts and labour as provided above. In no case shall The Companies be responsible for materials, components, or construction which 
are not manufactured or supplied by The Companies, or for the labour necessary to install, repair or remove such materials, components or construction. All 
replacement or repair components will be shipped F.O.B. the nearest The Companies factory. 

Qualifications To The Warranty

The Gas Appliance Warranty outlined above is further subject to the following qualifications:
(1)  The Gas Appliance must be installed in accordance with The Companies installation instructions and local building codes. The Warranty on this Montigo 

Gas Appliance covers only the component parts manufactured by The Companies. The use of components manufactured by others with this Montigo Gas 
Appliance could create serious safety hazards, may result in the denial of certification by recognized national safety agencies, and could be in violation of local 
building codes. This warranty does not cover any damages occurring from the use of any components not manufactured or supplied by The Companies

(2)  The Montigo Gas Appliance must be subjected to normal use. The Gas Appliances are designed to burn gas only. Burning conventional fireplace fuels such 

as wood, coal or any other solid fuel will cause damage to the Gas Appliance, will produce excessive temperatures and will result in a fire hazard.

Limitations On Liability

It is expressly agreed and understood that The Companies sole obligation, and purchaser's exclusive remedy under this Warranty, under any other warranty, 
expressed or implied, or in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specified above.
In no event shall The Companies be responsible for any incidental or consequential damages caused by defects in its products, whether such damage occurs 
or is discovered before or after replacement or repair, and whether or not such damage is caused by The Companies negligence. Some states do not allow the 
exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. The duration of any implied warranty 
with respect to this Montigo Gas Appliance is limited to the duration of the foregoing warranty. Some states do not allow limitation on how long an implied warranty 
lasts, so the above may not apply to you.

Investigation Of Claims Against Warranty

The Companies reserves the right to investigate any and all claims against this Warranty and to decide upon method of settlement.
The Companies Are Not Responsible For Work Done Without Written Consent
The Companies shall in no event be responsible for any warranty work done without first obtaining The Companies written consent.
Dealers Have No Authority To Alter This Warranty
The Companies employees and dealers have no authority to make any warranties nor to authorize any remedies in addition to or inconsistent with those stated 
above.

How To Register A Claim Against Warranty

In order for any claim under this Warranty to be valid, The Companies must be notified of the claimed defect in writing or by telephone, as soon as reasonably 
possible after the defect is discovered. Claims against this Warranty in writing should include the date of installation, and a description of the defect.

Other Rights

This Warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

NOTE:

 

The Companies

 as stated above refer to - Canadian Heating Products Inc. and/or Montigo Del Ray Corp.

Canadian  Heating  Products  Inc.  and/or  Montigo  DelRay  Corp.  reserves  the  right  to  make  changes  at  any  time,  without 

notice, in design, materials, specifications, prices and also to discontinue colors, styles and products.

Warranty

Содержание H-Series DF

Страница 1: ...aces are extremely hot while the fireplace is on and remain hot even after the fireplace has been turned off Safety screens are available and can reduce the risks of severe burns Please keep children away from the fireplace at all times C US Installer Leave this manual with the appliance Consumer Leave this man ual for future reference Check local codes and read all instructions prior to installat...

Страница 2: ...u years of durable reliable use Welcome to the Montigo family of gas fireplace products Safety Alert Key DANGER Indicates a hazardous situation which if not avoided will result in death or serious injury WARNING Indicates a hazardous situation which if not avoided could result in death or serious injury CAUTION Indicates a hazardous situation which if not avoided could result in minor or moderate ...

Страница 3: ...y component part not manufactured or approved by Montigo in combination with this Montigo fireplace system Installation other than as instructed in this manual Consult your local Gas Inspection Branch on installation requirements for factory built gas fireplaces Installation repairs should be done by a qualified contractor InstallationsinCanadamustconformtothecurrentCAN CGAB 149 1 and 2 Gas Instal...

Страница 4: ...t used behind the fireplace framing depth may be reduced by 5 8 Framing Top View Front View Side View Figure 1 Fireplace dimensions Rear Vent WARNING When this appliance is installed directly on carpeting tile or any combustible material other than wood flooring it must be installed on a metal or wood panel extending the full width and depth of the appliance 18 1 2 36 1 2 8 5 28 3 4 36 1 2 37 3 4 ...

Страница 5: ...a manifold pressure of 10 W C Provision must also be made for a 1 8 N P T plugged tapping and be accessible for test gauge connection immediately upstream of the gas supply controls to the appliance The fireplace gas connection and the main operating gas valve is located behind the removable trim at the bottom of the unit and need only be attached to the gas line with an approved fitting as requir...

Страница 6: ...nation where temperatures are highest 2 Attach to the faceplate of the termination using four sheet metal screws Installing Heat Guards over Terminations Installing The Remote Switch The H42DF O s gas valve located behind the lower trim may be connected to a wall switch The valve generates its own power on a millivolt circuit Use only low voltage wire and DO NOT connect any external power to it Re...

Страница 7: ...llation for Rear Vented fireplace Figure 8b Flue collar installation for Rear Vented fireplace H Series DF Rear Vent Use the following instructions to convert an H42DF O for Top Vent use Install the 4 or 5 inner flue cap on the top flue outlet and secure 1 the cap in place with five screws as shown in figure 8a Install the 7 or 8 outer flue cap on the top flue outlet and secure 2 it with five scre...

Страница 8: ...nsion lengths for vertical or horizontal runs are measured from centre of the vent pipe Venting runs must fall within the limits set by the venting graph see Figure 7 PEL RHS8 Heat Shield Available Top Vent Components The following venting components are available for the H42DF O Top Vent 4 7 Venting 5 8 Venting A Termination MTO 3 3 Length MTO 3F 3 Length PTO 3 3 Length PTO 3F 3 Length B Stucco K...

Страница 9: ...al length of 3 feet see Figure 14 Flex runs over 3 feet must fall within the limits set by the venting graph and must have a minimum vertical rise of 3 per foot of flex RHS8 Heat Sheild RHS8 Heat Shield Figure 13 RetractedInstallationusingacombinationofsolidandflex venting Usetheventgraphtodetermineyourallowable run then select appropriate components Figure 14 Horizontal flex installation with no ...

Страница 10: ...ction MEXT 3 36 m f Section MEXT 4 48 m f Section PEXT 1 12 m f Section PEXT 2 24 m f Section PEXT 3 36 m f Section PEXT 4 48 m f Section D Support Ring Plate MSPXT 8 PSPXT 8 E Firestop FS 8 PS 8 F Roof Flashing MRF 7 1 12 7 12 pt MRF 12 7 12 12 12 pt PRF 7 1 12 7 12 pt PRF 7 7 12 12 12 pt G Adaptor Vent Reducer PVA5487 5 8 to 4 7 Figure 15 Straight verticalventingshowingrequiredMXT 10 PXT 10 adap...

Страница 11: ...e that you install the RHS101 heat shield Heat Shield The heat shield RHS101 must be used on all installations straight through the wall at the point where the vent pipe connects to the termination With the heat shield proper vent clearances can be maintained The heat shield is not included with the fireplace Toinstalltheheatshield slideonesectionovertheventpipeontheinside of the wall opening with...

Страница 12: ...re to the following guidelines the first 90 elbow must be placed directly on the flue collar you must have a minimum vertical lift of 50 measured from the hearth your vent run must fall within the limits set by Figure 22a Before you install any venting you must determine whether the venting run will be acceptable Unacceptable venting can affect the fireplace s combustion The Venting Graph Measure ...

Страница 13: ...ot project beyond shaded area shown in Figure 24 Side wall clearances are 3 Combustible surrounds may be installed with 3 clearance to the side of the fireplace as shown in Figure 25 Figure 24 Combustible mantles and facings Fireplace Facing When selecting the finish material for your fireplace it is important to remember the following If the surround of the fireplace is to be painted to match the...

Страница 14: ...se Steps below to remove the Horizontal access panel unlatch the door buckles and remove the door Replace in reverse order Figure 28a Loccate the door buckles Both Sides Typical Door Latch Hook Door Latch Slot Hand hold Release the Door Buckles Figure28 RemovingandinstallingthetheHorizontalAcessPanel Locate the Door Buckles Figure 28b Door buckle Tool 1 Step 4 Firmly grasp hand hold end of Door bu...

Страница 15: ...oor Figure 29 Installation of glass beads Installing the Glass Beads and Optional River Rocks Beads The LS38 DFO is supplied with Designer Glass beads Remove the Door and trim as shown in the previous Instruction Follow these instructions to ensure all parts are removed or replaced as required Once the Trim and glass doors are removed place the marbles ran domly across the pan surrounding the burn...

Страница 16: ...logs as shown above figure 30c insets Step 5 PlacetheCentreFrontlog Figure30dbelow asshownusingthe notch cast in the Bottom Rear log as shown in figure 30c above Figure 30d Placing Centre Front Log Step 7 Place the Right Centre log as shown in figure 30e Figure 30e Placing Right Center Log Step 8 Place the Right Center log as shown using the notch in the Top Right log as a guide figure 30f Figure ...

Страница 17: ...g Log C and Right front Log Log B Step 3 Place the bottom Right log Log B and bottom Left Log Log C as shown in figure 30b Air Inlets Pilot Assembly Fireplace Base Rear Bottom Log Notch in Log Log A Air Inlets Fireplace Base Log D Figure 30c Top Left Log Log D Air Inlets Fireplace Base Log E Step 5 Place Front Left log Log D as shown in figure 30c Figure 30e Top Right Log Log E Step 6 Place Front ...

Страница 18: ...Off Gas To Appliance 3 Push in gas control knob slightly and turn clockwise to Off Do not force 4 Replace the lower Horizontal access panel 1 Turn off remote switch 2 Remove the lower Horizontal access panel 1 STOP Read the safety information above on this label 2 Remove the lower Horizontal access panel 3 Push in gas control knob and turn clockwise to OFF 4 Wait five 5 minutes to clear out any ga...

Страница 19: ...ght any appliance Q Q Do not touch any electrical switch do not use any phone Q Q in your building Immediately call your gas supplier from a neighbour s Q Q phone Follow the gas supplier s instructions 1 Turn off remote switch 2 Remove the lower Horizontal access panel 3 Turn the switch on the gas control to Off 4 Replace the lower Horizontal access panel 1 STOP Read the safety information above o...

Страница 20: ...es locate the black knob marked Hi Lo in the centre of the gas control valve See Figure 32 The front burners are not adjustable To raise the flame height turn the black knob located behind the lower trim counter clockwise To lower the flame height turn clockwise Figure 32 Hi Lo Adjustment on the H42DF O s gas valve Cleaning When the fireplace is first activated there may be some smoking and a visi...

Страница 21: ...t operate correctly consult your dealer or the manufacturer All service and repairs should be performed by a qualified agency All spare parts optional fans and optional trim finishes are available from your local dealer or the manufacturer H42DF O I Turn Gas Supply Off Set thermostat to call for heat SV9500 SV9600 is powered 24VAC nominal HSI Terminals NOTE Before Troubleshooting Familiarize Yours...

Страница 22: ...42DF O NG Gas Valve RGC1004 LP Gas Valve RGC1003 NG Pilot RPA003 LP Pilot RPA004 Burner NG RBH4201SS Burner LPG RBH4202SS ROR1124 ROR1125 Door RDTH42SS Log Set RLGSH42 Log Base RLGSH42B H42DF O I RGC1006 RGC1005 RPA020 RPA021 RBH4201SS RBH4202SS ROR1125 RDTH42SS RLGSH42 RLGSH42B ROR1124 ...

Страница 23: ...o normal use The Gas Appliances are designed to burn gas only Burning conventional fireplace fuels such as wood coal or any other solid fuel will cause damage to the Gas Appliance will produce excessive temperatures and will result in a fire hazard Limitations On Liability It is expressly agreed and understood that The Companies sole obligation and purchaser s exclusive remedy under this Warranty ...

Страница 24: ...m in the United States 6 feet 1 8 m minimum in Canada L clearance to non mechanical air supply inlet to building or the combustion air inlet to any other appliance 16 inches 41 cm minimum for appliances 100 000 BTU H 30kW M clearance to mechanical air supply inlet 6 feet 1 8 m minimum N clearance above paved sidewalk or a paved driveway located on public property 7 feet 2 1 m minimum P clearance u...

Страница 25: ...ly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon inspectio...

Страница 26: ...Canadian Heating Products Inc Langley BC V4W 4A1 Montigo Del Ray Corp Ferndale WA 98248 XG0149 010909 ...

Отзывы: