H42DF-O Outdoor Gas Fireplace

Part No. XG0149

 

Operation - Model H42DF-O

H42DF-O

WARNING:

 

If you do not follow these instructions exactly, a fire or explosion may 

result causing property damage, personal injury or loss of life.

If  you  cannot  reach  your  gas  supplier,  call  the  Fire 

 

Q

Department.

C.

  Use only your hand to push in or turn the gas control knob. 

Never use tools. If  the knob will not push in or turn by hand, 
don't try to repair it, call a qualified service technician. Force 
or attempt to repair may result in a fire or explosion.

D.

  Do not use this appliance if any part has been under water. 

Immediately call a qualified service technician to inspect the 
appliance and to replace any part of the control system, and 
any gas control which has been under water.

A. 

This appliance has a pilot which must be lighted by hand. 
When lighting the pilot, follow these instructions exactly.

B.  BEFORE LIGHTING

 smell all around the appliance area for 

gas.  Be sure to smell next to the floor because some gas is 
heavier than air and will settle on the floor.

 

What To Do If You Smell Gas:

Do not try to light any appliance.

 

Q

Do not touch any electrical switch; do not use any phone 

 

Q

in your building.
Immediately call your gas supplier from a neighbour's 

 

Q

phone. Follow the gas supplier's instructions.

To Turn Off Gas To Appliance:

3.  Push in gas control knob slightly and turn  

  clockwise to 

"Off".  Do not force.

4.  Replace the lower Horizontal access panel

1.  Turn off remote switch.
2.  Remove the lower Horizontal access panel

1.

 

STOP!

 

 

Read the safety information above on this label.

2.

  Remove the lower Horizontal access panel

3.

  Push in gas control knob and turn clockwise 

  to "OFF."

4.

  Wait  five  (5)  minutes  to  clear  out  any  gas.  Smell  for  gas, 

including near the floor. If you then smell gas, 

STOP!

 Follow 

"B" in the safety information above on this label. If you don't 
smell gas, go to the next step.

5.

  Locate pilot burner 

(See illustration at right.)

 and follow steps 

below.

6.

  Turn  knob  on  gas  control  counter  clockwise   

    to 

"PILOT."

7.

  Push in gas control knob completely and hold. Light with Piezo 

Igniter button. Continue to hold the control knob in for about 
(1) minute after the pilot is lit. Release the knob and it will pop 
back up. Pilot should remain lit. If it goes out repeat steps 3 
through 8.

If  knob  does  not  pop  up  when  released.  Stop  and 

 

Q

immediately  call  your  service  technician  or  gas 
supplier.
If the pilot will not stay lit after several 

 

Q

tries,  turn  the  gas  control  knob  to 
"OFF" and call your service technician 
or gas supplier.

8.

  Push in gas control knob and turn counter-

clockwise  

  to "ON."

9.

  Replace  the  lower  Horizontal  access 

panel

10. 

Turn on remote switch to ignite fire.

Lighting  Instructions:

with Continuous  Pilot

For Your Safety - READ BEFORE LIGHTING:

NOTE: 

Gas control knob cannot be turned from 

 

"PILOT" to "OFF" unless knob is pushed

 

 in slightly.  Do not force.

Содержание H-Series DF

Страница 1: ...aces are extremely hot while the fireplace is on and remain hot even after the fireplace has been turned off Safety screens are available and can reduce the risks of severe burns Please keep children away from the fireplace at all times C US Installer Leave this manual with the appliance Consumer Leave this man ual for future reference Check local codes and read all instructions prior to installat...

Страница 2: ...u years of durable reliable use Welcome to the Montigo family of gas fireplace products Safety Alert Key DANGER Indicates a hazardous situation which if not avoided will result in death or serious injury WARNING Indicates a hazardous situation which if not avoided could result in death or serious injury CAUTION Indicates a hazardous situation which if not avoided could result in minor or moderate ...

Страница 3: ...y component part not manufactured or approved by Montigo in combination with this Montigo fireplace system Installation other than as instructed in this manual Consult your local Gas Inspection Branch on installation requirements for factory built gas fireplaces Installation repairs should be done by a qualified contractor InstallationsinCanadamustconformtothecurrentCAN CGAB 149 1 and 2 Gas Instal...

Страница 4: ...t used behind the fireplace framing depth may be reduced by 5 8 Framing Top View Front View Side View Figure 1 Fireplace dimensions Rear Vent WARNING When this appliance is installed directly on carpeting tile or any combustible material other than wood flooring it must be installed on a metal or wood panel extending the full width and depth of the appliance 18 1 2 36 1 2 8 5 28 3 4 36 1 2 37 3 4 ...

Страница 5: ...a manifold pressure of 10 W C Provision must also be made for a 1 8 N P T plugged tapping and be accessible for test gauge connection immediately upstream of the gas supply controls to the appliance The fireplace gas connection and the main operating gas valve is located behind the removable trim at the bottom of the unit and need only be attached to the gas line with an approved fitting as requir...

Страница 6: ...nation where temperatures are highest 2 Attach to the faceplate of the termination using four sheet metal screws Installing Heat Guards over Terminations Installing The Remote Switch The H42DF O s gas valve located behind the lower trim may be connected to a wall switch The valve generates its own power on a millivolt circuit Use only low voltage wire and DO NOT connect any external power to it Re...

Страница 7: ...llation for Rear Vented fireplace Figure 8b Flue collar installation for Rear Vented fireplace H Series DF Rear Vent Use the following instructions to convert an H42DF O for Top Vent use Install the 4 or 5 inner flue cap on the top flue outlet and secure 1 the cap in place with five screws as shown in figure 8a Install the 7 or 8 outer flue cap on the top flue outlet and secure 2 it with five scre...

Страница 8: ...nsion lengths for vertical or horizontal runs are measured from centre of the vent pipe Venting runs must fall within the limits set by the venting graph see Figure 7 PEL RHS8 Heat Shield Available Top Vent Components The following venting components are available for the H42DF O Top Vent 4 7 Venting 5 8 Venting A Termination MTO 3 3 Length MTO 3F 3 Length PTO 3 3 Length PTO 3F 3 Length B Stucco K...

Страница 9: ...al length of 3 feet see Figure 14 Flex runs over 3 feet must fall within the limits set by the venting graph and must have a minimum vertical rise of 3 per foot of flex RHS8 Heat Sheild RHS8 Heat Shield Figure 13 RetractedInstallationusingacombinationofsolidandflex venting Usetheventgraphtodetermineyourallowable run then select appropriate components Figure 14 Horizontal flex installation with no ...

Страница 10: ...ction MEXT 3 36 m f Section MEXT 4 48 m f Section PEXT 1 12 m f Section PEXT 2 24 m f Section PEXT 3 36 m f Section PEXT 4 48 m f Section D Support Ring Plate MSPXT 8 PSPXT 8 E Firestop FS 8 PS 8 F Roof Flashing MRF 7 1 12 7 12 pt MRF 12 7 12 12 12 pt PRF 7 1 12 7 12 pt PRF 7 7 12 12 12 pt G Adaptor Vent Reducer PVA5487 5 8 to 4 7 Figure 15 Straight verticalventingshowingrequiredMXT 10 PXT 10 adap...

Страница 11: ...e that you install the RHS101 heat shield Heat Shield The heat shield RHS101 must be used on all installations straight through the wall at the point where the vent pipe connects to the termination With the heat shield proper vent clearances can be maintained The heat shield is not included with the fireplace Toinstalltheheatshield slideonesectionovertheventpipeontheinside of the wall opening with...

Страница 12: ...re to the following guidelines the first 90 elbow must be placed directly on the flue collar you must have a minimum vertical lift of 50 measured from the hearth your vent run must fall within the limits set by Figure 22a Before you install any venting you must determine whether the venting run will be acceptable Unacceptable venting can affect the fireplace s combustion The Venting Graph Measure ...

Страница 13: ...ot project beyond shaded area shown in Figure 24 Side wall clearances are 3 Combustible surrounds may be installed with 3 clearance to the side of the fireplace as shown in Figure 25 Figure 24 Combustible mantles and facings Fireplace Facing When selecting the finish material for your fireplace it is important to remember the following If the surround of the fireplace is to be painted to match the...

Страница 14: ...se Steps below to remove the Horizontal access panel unlatch the door buckles and remove the door Replace in reverse order Figure 28a Loccate the door buckles Both Sides Typical Door Latch Hook Door Latch Slot Hand hold Release the Door Buckles Figure28 RemovingandinstallingthetheHorizontalAcessPanel Locate the Door Buckles Figure 28b Door buckle Tool 1 Step 4 Firmly grasp hand hold end of Door bu...

Страница 15: ...oor Figure 29 Installation of glass beads Installing the Glass Beads and Optional River Rocks Beads The LS38 DFO is supplied with Designer Glass beads Remove the Door and trim as shown in the previous Instruction Follow these instructions to ensure all parts are removed or replaced as required Once the Trim and glass doors are removed place the marbles ran domly across the pan surrounding the burn...

Страница 16: ...logs as shown above figure 30c insets Step 5 PlacetheCentreFrontlog Figure30dbelow asshownusingthe notch cast in the Bottom Rear log as shown in figure 30c above Figure 30d Placing Centre Front Log Step 7 Place the Right Centre log as shown in figure 30e Figure 30e Placing Right Center Log Step 8 Place the Right Center log as shown using the notch in the Top Right log as a guide figure 30f Figure ...

Страница 17: ...g Log C and Right front Log Log B Step 3 Place the bottom Right log Log B and bottom Left Log Log C as shown in figure 30b Air Inlets Pilot Assembly Fireplace Base Rear Bottom Log Notch in Log Log A Air Inlets Fireplace Base Log D Figure 30c Top Left Log Log D Air Inlets Fireplace Base Log E Step 5 Place Front Left log Log D as shown in figure 30c Figure 30e Top Right Log Log E Step 6 Place Front ...

Страница 18: ...Off Gas To Appliance 3 Push in gas control knob slightly and turn clockwise to Off Do not force 4 Replace the lower Horizontal access panel 1 Turn off remote switch 2 Remove the lower Horizontal access panel 1 STOP Read the safety information above on this label 2 Remove the lower Horizontal access panel 3 Push in gas control knob and turn clockwise to OFF 4 Wait five 5 minutes to clear out any ga...

Страница 19: ...ght any appliance Q Q Do not touch any electrical switch do not use any phone Q Q in your building Immediately call your gas supplier from a neighbour s Q Q phone Follow the gas supplier s instructions 1 Turn off remote switch 2 Remove the lower Horizontal access panel 3 Turn the switch on the gas control to Off 4 Replace the lower Horizontal access panel 1 STOP Read the safety information above o...

Страница 20: ...es locate the black knob marked Hi Lo in the centre of the gas control valve See Figure 32 The front burners are not adjustable To raise the flame height turn the black knob located behind the lower trim counter clockwise To lower the flame height turn clockwise Figure 32 Hi Lo Adjustment on the H42DF O s gas valve Cleaning When the fireplace is first activated there may be some smoking and a visi...

Страница 21: ...t operate correctly consult your dealer or the manufacturer All service and repairs should be performed by a qualified agency All spare parts optional fans and optional trim finishes are available from your local dealer or the manufacturer H42DF O I Turn Gas Supply Off Set thermostat to call for heat SV9500 SV9600 is powered 24VAC nominal HSI Terminals NOTE Before Troubleshooting Familiarize Yours...

Страница 22: ...42DF O NG Gas Valve RGC1004 LP Gas Valve RGC1003 NG Pilot RPA003 LP Pilot RPA004 Burner NG RBH4201SS Burner LPG RBH4202SS ROR1124 ROR1125 Door RDTH42SS Log Set RLGSH42 Log Base RLGSH42B H42DF O I RGC1006 RGC1005 RPA020 RPA021 RBH4201SS RBH4202SS ROR1125 RDTH42SS RLGSH42 RLGSH42B ROR1124 ...

Страница 23: ...o normal use The Gas Appliances are designed to burn gas only Burning conventional fireplace fuels such as wood coal or any other solid fuel will cause damage to the Gas Appliance will produce excessive temperatures and will result in a fire hazard Limitations On Liability It is expressly agreed and understood that The Companies sole obligation and purchaser s exclusive remedy under this Warranty ...

Страница 24: ...m in the United States 6 feet 1 8 m minimum in Canada L clearance to non mechanical air supply inlet to building or the combustion air inlet to any other appliance 16 inches 41 cm minimum for appliances 100 000 BTU H 30kW M clearance to mechanical air supply inlet 6 feet 1 8 m minimum N clearance above paved sidewalk or a paved driveway located on public property 7 feet 2 1 m minimum P clearance u...

Страница 25: ...ly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon inspectio...

Страница 26: ...Canadian Heating Products Inc Langley BC V4W 4A1 Montigo Del Ray Corp Ferndale WA 98248 XG0149 010909 ...

Отзывы: