Page 4
H42DF-O Outdoor Gas Fireplace
Part No. XG0149
Installation
Installing The Fireplace Shell
The fireplace may be installed in any location that maintains proper clear
-
ances to air conditioning ducts, electrical wiring and plumbing. Safety,
as well as efficiency of operation, must be considered when selecting
the fireplace location. Try to select a location that does not interfere
with room traffic, has adequate ventilation, and offers an accessible
pathway for Direct Vent installation. Refer to page 4 -
Vent Installation
for more information.
The fireplace dimensions are shown below:
When installing a shelf over the top of the fireplace, the following
guidelines must be adhered to: For Rear Vent applications the
minimum clearance from the top of the fireplace to a shelf is 9". For
Top Vent applications, the minimum clearance is 17 1/2". (
Minimum
2" clearance must still be maintained around the vent pipes.
)
Figure 4.
Framing for shelves over the fireplace.
Top Vent
Figure 3.
Minimum Corner framing dimensions, using a 45° elbow.
Figure 2.
Framing dimensions.
* When sheetrock is
not used behind the
fireplace, framing
depth may be reduced
by 5/8"
Framing
Top View
Front View
Side View
Figure 1.
Fireplace dimensions.
Rear Vent
WARNING!
When this appliance is installed directly on carpeting, tile or any
combustible material other than wood flooring, it must be installed
on a metal or wood panel extending the full width and depth of
the appliance.
18 1/2”
36 1/2
8”
5”
28 3/4
36 1/2
37 3/4
35 1/4
1 1/4
1 1/4
1 1/4
1
5 1/2”
5 1/4”
25 3/4
18 1/2”
25”
J
K
CL
11 1/2
CL
8”
5”
Clearances
These clearances apply to all dimensions
except the framed opening
,
where the clearance to combustibles is
0"
. The
H42DF-O
clearance to
unprotected combustible walls which are perpendicular to the fireplace
opening, must not project beyond the shaded area shown in Fig. 24.
For protection against freezing temperatures, it is recommended that
outer walls of the chase be insulated with a vapor barrier. This will reduce
the possibility of a cold-air convection current on the fireplace.
* Clearance from top of the
Fireplace
to a combustible ceiling within the fireplace
enclosure.
** Refer to Pages, 10 & 11.
37 3/4”
46 3/8”
20 1/8”
68”
42”
48 1/8”
46 3/8
50 1/8
10
40 1/8
Header
Header
Shelf
MEL Short
Shelf
33
46 3/8
19
H42DF-O
Top - Rear Vent *
9"
Top - Top Vent
17
1
/
2
"
Back
1"
Sides
1"
Floor
0"
Mantle**
4"