background image

Page 2

Page 2

Page 2

Page 2

Page 2

E38-PV Gas Fireplace

Part No. XM0500

Introduction

About the E38-PV Power Vented Fireplaces:

The E38-PV is rated for Natural Gas at 22,000 BTU/H (6.45 Kilo-
watts) Input or

 

Propane at 22,000 BTU/H (6.45 Kilowatts) Input.

Montigo's Power Vent system is ideal for extremely long or difficult
venting runs, which are beyond the capability of a direct vent model.

Warranty and Installation Information:

The Montigo warranty will be voided by, and Montigo

 

disclaims any

responsibility for, the following actions:

n

Modification of the fireplace and/or components including vent
assembly or glass doors.

n

Use of any component part not manufactured or approved by
Montigo in combination with this Montigo fireplace system.

n

Installation other than as instructed in this manual.

Consult your local Gas Inspection Branch on installation requirements
for factory-built gas fireplaces. Installation & repairs should be done
by a qualified contractor.

Installations in Canada

 must conform to the current 

CAN/CGA B-

149.1

 and 

.2

 Gas Installation Code and local regulations. This

appliance must be electrically grounded in accordance with 

CSA

C22.1

 Canadian Electrical Code Part 1 and/or Local Codes.

Installations in the USA

 must conform to local codes, or in the

absense of local codes to the National Fuel Gas Code, 

ANSI Z223.1-

1988

. The appliance must be grounded in accordance with local

codes or, in the absence of local codes, with the National Electrical
Code, 

ANSI/NFPA 70-1987.

Table Of Contents

Introduction .............................................................................

2

Installation

Installing the Fireplace Shell ......................................... 3

Installing the Gasline ..................................................... 4

Electrical Supply ........................................................... 4

The Remote Switch ....................................................... 4

Vent Terminations ......................................................... 5

Venting ......................................................................... 6

Setting up for Left or Right Exhaust .................. 6

Vent Installation Requirements ......................... 6

Flex Vent Installation ........................................ 7

Available Standard Series Components ........... 7

Removing and Installing the Insert ................................ 8

Removing and Installing the Door ................................. 8

Fan Wiring ..................................................................... 9

Installing the Logset ...................................................... 9

Finishing around the fireplace

Facing ............................................................. 10

Mantels and Surrounds ................................... 10

Operation ...............................................................................

11

Maintenance ...................................................................

12 - 13

Warranty .................................................................................

14

Appendix

A. Accessories ............................................................ 15

B. Termination Locations ............................................ 16

CAUTIONS

CAUTIONS

CAUTIONS

CAUTIONS

CAUTIONS

Due  to  its  high  operating  temperatures,  the  appliance
should  be located out of traffic & away from furniture and
draperies.

n

Children and adults should be alerted to the hazards
of the high surface temperature, which could cause
burns or clothing ignition.

n

Young children should be carefully supervised when
they are in the same room as the appliance.

n

Clothing or other flammable materials should not be
placed on or near the appliance.

Содержание E38-PV

Страница 1: ... Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Warning Improper installation adjustment alteration serviceormaintenancecancause injury or property damage Refer to this manual For assistance or additional informat...

Страница 2: ...ode Part 1 and or Local Codes Installations in the USA must conform to local codes or in the absense of local codes to the National Fuel Gas Code ANSI Z223 1 1988 The appliance must be grounded in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 1987 Table Of Contents Introduction 2 Installation Installing the Fireplace Shell 3 Installing ...

Страница 3: ...to the fireplace opening must not project beyond the shaded area shown in Figure 19b For protection against freezing temperatures it is recommended that outer walls of the chase be insulated with a vapour barrier This will reduce the possibility of a cold air convection current on the fireplace Top View Front View Side View Clearances The E38 PV clearances to combustible materials are Top 1 Back 0...

Страница 4: ...psig 3 5 kPa The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5 kPa Installing The Remote Switch The E38 PV s gas valve located behind the lower brass trim may be connected to a wall switch or a hand held remote The valve oper...

Страница 5: ...tion Before installing the termination or venting check to ensure the planned termination location is acceptable For a detailed illustration of allowed termination locations see Appendix B 11 11 Installing Power Vent Reverse Terminations When terminating a vent run below a soffit or an overhang use the Drop Termination to increase the clearance between the termination and the finish materials 1 Fr...

Страница 6: ...hand exhaust Figure 9 Left hand exhaust Venter Motor 4 x Machine screws Flexible vent Upper housing cover Vent Installation Installation Requirements n E38 PV fireplaces are certified for use with Montigo Power Vent components and Standard Series 4 7 venting components n 0 clearance to combustibles for vent pipes n Use only certified Montigo vent components Use of other parts will void the Montigo...

Страница 7: ... feet to prevent the vent from sagging 6 Maximum 60 feet of vent allowed with 4 x 90 bends 7 The flexible vent is tested for 0 clearance to combustibles Allowable number of 90 Bends per vent length Length of 90 Bends 60 feet 4 x 90 45 feet 4 x 90 30 feet 5 x 90 25 feet 5 x 90 20 feet 6 x 90 Example 25 feet of flexible vent length would allow the use of five 5 90 degree elbows NOTES All dimension l...

Страница 8: ...t A Magnet Pull bottom of door surround outwards and upwards Glass door frame Figure 13b Removing or installing the glass door Removing and Installing the Insert You may remove the insert to protect it from theft and damage during construction 1 Remove the two machine screws 1 left 1 right at the top of the insert that attach the insert to the shell See Figure12 Inset 1 2 Remove the 4 machine scre...

Страница 9: ...A Log C Log B NOTES n If logs are not placed properly excessive sooting will result n The surface of the logs will crack due to the heat from the flames This is a normal occurance Figure 14a Wiring for optional air circulating fan kit G L1 WH L2 BLK Quick Connect plug to motor NOTE If any of the original wire supplied with the appliance is replaced it must be replaced with the same type or its equ...

Страница 10: ...ngs Mantels Surrounds NOTE National Canadian Gas Association mantel test requirements are for fire hazard prevention to combustible materials New technology to meet consumer and government demands for the wise use of energy has prompted us to manufacture many models of fireplaces which are hot fuel and energy efficient Please be aware temperatures over the mantel will rise above normal room temper...

Страница 11: ... try to light any appliance n Do not touch any electrical switch do not use any phone in your building n Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions 1 Turn off remote switch 2 Flip down lower brass trim 3 Turn the switch on the gas control to Off 4 Flip up brass trim 1 STOP Read the safety information above on this label 2 Flip down lower bras...

Страница 12: ...s and liquids n Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water Cleaning When the fireplace is first activated there may be some smoking and a visible film may be left on the glass This is a normal condition and is the resu...

Страница 13: ...correctly consult your dealer or the manufacturer All service and repairs should be performed by a qualified agency All spare parts optional fans and optional trim finishes are available from your local dealer or the manufacturer HONEYWELL SV 9500 SV9600 Troubleshooting Sequence NOTE Before Troubleshooting Familiarize Yourself With The Startup And Checkout Procedure Turn Gas Supply off Set thermos...

Страница 14: ...or any other solid fuel will cause damage to the Gas Appliance will produce excessive temperatures and will result in a fire hazard Limitations On Liability Limitations On Liability Limitations On Liability Limitations On Liability Limitations On Liability It is expressly agreed and understood that The Companies sole obligation and purchaser s exclusive remedy under this Warranty under any other w...

Страница 15: ...14 15 Available Options and Accessories 1 Add on Bay Window 2 Hand Held Remote Control 3 Variable Speed Blower Kit 4 2 Fan Kit 5 4 Fan Kit 6 4 Piece Picture Frame Surround PFS 7 3 Piece Picture Frame Surround PFO 8 Door Cover Square DF0 9 Door Cover Arched DFA 10 Horizontal Trim Kits Black Brass Nickel 11 Replacement Logset ...

Страница 16: ...ations 12 12 12 18 Pitched Roof Flat Roof 18 12 Top Parapet Wall 12 Min to Ceiling RECESSED AREA 12 12 24 36 72 72 12 12 12 12 12 72 Service Regulator Vent Must be a solid Balcony Three Balcony Two 2 Unvented Soffit Termination of vent within outlined zone not permitted Gas Service Riser Grade 36 24 12 ...

Страница 17: ...Page 17 Page 17 Page 17 Page 17 Page 17 E38 PV Gas Fireplace Part No XM0500 Notes ...

Страница 18: ...Canadian Heating Products Inc Surrey BC V3W 2V6 Montigo Del Ray Corp Ferndale WA 98248 XG0500 Rev 00 01 99 ...

Отзывы: