The following is a troubleshooting chart of possible problems:
7URXEOHVKRRWLQJ6Ζ73URIODPH
The following is a troubleshooting chart of possible problems:
ΖI\RXUȴUHSODFHVWLOOGRHVQRWRSHUDWHFRUUHFWO\FRQVXOW\RXUORFDO
Montigo dealer.
$OOVHUYLFHDQGUHSDLUVVKRXOGEHSHUIRUPHGE\DTXDOLȴHG
Technician.
Spare parts and accesories are available from your local Montigo
dealer.
PROBLEM
SOLUTION
Noisy Pilot
Flame
Locate pilot adjustment screw on gas control
valve. Flame is decreased by turning adjustment
screw clockwise.
Pilot won't
ignite
Disconnect remote wires and try to light pilot. If
pilot now works, remote connections are faulty.
Check wiring diagram
Main burner
will not light
1. Check wiring
2. Check wall switch for proper connection
PROBLEM
SOLUTION
Pilot Igniter
won't spark
1. Check the MAIN ON-OFF switch (typically
located below the valve cover) and turn ON
2. Ensure main power is ON or new batteries
are installed in the remote control and backup
battery pack (if available).
3. Check the 3.15A fuse in the control box and
replace if necessary
Pilot Igniter
sparking, but
Pilot burner
will not light
1. Verify the Inlet and Manifold Gas Pressure are
within acceptable limits
2. Check all connections to gas valve
3. Check connection to stepper motor (if
available)
Pilot lights , but
Main burner
will not Light
1. Check and verify all wiring connections as per
the wiring diagram.
2 . Verify the inlet and Manifold Pressure are
within acceptable limits
Pilot lights , but
Main burner
will not Light
and igniter
continues to
spark
1. Check the Pilot Flame Sensor Rod and clean
with steel wool or similar.
2. Check the Pilot hood and clean with steel wool
if dirty.
$GMXVWSLORWȵDPHXVLQJWKHSLORWDGMXVWPHQW
VFUHZLIWKHSLORWȵDPHLVWRRORQJRUWRRVKRUW
(Flame should fully engulf the sensor rod and
must be stable).
4. Check and make sure the ground wire from
WKHSLORWLVFRQQHFWHGWRWKHȴUHSODFHERG\
Fans not
working
(QVXUHPDLQSRZHULV21ȴUHSODFHPD\EH
operating on back up batteries).
2. Check the 3.15A fuse in the control box and
replace if necessary
Annual inspection list for determining safe operation of
a direct vent gas
ȴ
replace
1)
Inspect and operate the pressure relief mechanism to verify relief mechanisms are free
from obstruction to operate.
2)
&OHDQJODVVZLQGRZZLWKDVXLWDEOHȴUHSODFHJODVVFOHDQHU$EUDVLYHFOHDQHUVPXVWQRW
be used. Be careful not to scratch the glass when cleaning.
3)
ΖQVSHFWWKHRSHUDWLRQRIWKHȵDPHVDIHW\V\VWHP3LORWRU)ODPHUHFWLȴFDWLRQGHYLFH
4)
Inspect and ensure the lighting of the main burner occurs within 4 seconds of the
main gas valve opening. Visual inspection should match that outlined in the appliance
instruction manual. Inspect primary air openings for blockage.
5)
Inspect condition of vent and vent terminal for sooting or obstruction and correct if
present.
6)
9DFXXPDQGFOHDQDQ\GHEULVLQWKHȴUHER[WKDWLVQRWVXSSRVHGWREHWKHUH
7)
7HVWDQGPHDVXUHWKHȵDPHIDLOXUHUHVSRQVHWLPHRIWKHȵDPHVDIHW\V\VWHPΖWPXVW
GHHQHUJL]HWKHVDIHW\VKXWRLQQRPRUHWKDQVHFRQGV
8)
Check all accessible gas-carrying tubes, connections, pipes and other components for
leaks.