10
Installation
xg0226 - 042220
13"
MIN.
DELRAY
UNIT
MTO-4F
OUTDOOR
WALL
FLEX
PIPE
FLOOR
1:32
DWG. NO.
SHEET 1 OF 2
WEIGHT:
MNR36 Complete Assembly
Finish
MATERIAL
Revision / Date
Drawn by
DATE
NAME
26/09/2018
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF CANADIAN HEATING PRODUCTS. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF CANADIAN HEATING PRODUCTS IS PROHIBITED.
PROPRIETARY AND CONFIDENTIAL
Y:\Products\Residential Products\R&D Projects\MNR36\CAD Drawing
s\MNR36 Complete Assembly
December-18-18 1:38:11 PM
SCALE
DM
Description
DelRay - Venting Assembly.
Revision
DIMENSIONS ARE IN INCHES
TOLERANCES:
FRACTIONAL 1/32"
TWO PLACE DECIMAL .015"
THREE PLACE DECIMAL .005"
ANGULAR .5
ALL BENDS ARE ASSUMED
TO BE 90 UNLESS NOTED
OTHERWISE.
Figure 4.bb
Minimum Horizontal vent run (Flex)
Figure 4.bb
Minimum Horizontal vent run (Rigid)
vERTIcAL TABLE
Horizontal
Maximum
H1+H2
10'
20'
vertical
Minimum
v1+v2+v3
4'
8'
HORIZONTAL TABLE
Horizontal
Maximum
H1+H2+H3
10'
20'
vertical
Minimum
v1+v2
4'
8'
Wall and Roof mounted venting
34' MAXIMUM VERTICAL HEIGHT
20' MAXIMUM HORIZONTAL OFFSETS
4 MAXIMUM 90° ELBOWS PERMITTED
The minimum vent system for horizontal termination must consist of:
13" to vent center, then straight out the wall (using flex kit)
The maximum vent system consists of:
34’ vertical length with 4 - 90° bends and a 20’ horizontal length
(measured to center of pipe)
Maximum Vertical vent run:
34’ vertical length with a roof termination,
restrictor recommended.
Maximum Horizontal vent run:
34’ vertical length with 4 elbows, and
the maximum 20 feet horizontal run.
16 18 "
MIN.
OUTDOOR
WALL
MTO-4F
DELRAY
UNIT
FLOOR
REVISIONS
REV.
DESCRIPTION
DATE
CHANGED BY
-
.
-
-
1:24
DWG. NO.
SHEET 2 OF 2
WEIGHT:
Finish
MATERIAL
DIMENSIONS ARE IN INCHES
TOLERANCES:
FRACTIONAL 1/32"
TWO PLACE DECIMAL .015"
THREE PLACE DECIMAL .005"
ANGULAR .5
ALL BENDS ARE ASSUMED
TO BE 90 UNLESS NOTED
OTHERWISE.
Revision / Date
Drawn by
DATE
NAME
26/09/2018
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF CANADIAN HEATING PRODUCTS. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF CANADIAN HEATING PRODUCTS IS PROHIBITED.
PROPRIETARY AND CONFIDENTIAL
Y:\Products\Residential Products\R&D Projects\MNR36\CAD Drawing
s\MNR36 Complete Assembly
December-18-18 1:38:11 PM
SCALE
DM
Description
DelRay - Venting Assembly.
Revision
MNR36 Complete Assembly
H1
H1
H2
H3
H2
v2
v2
v3
v1
v1
37 1/2'' Min.
40.652'' Min.
Section 3-3-1: venting Layout