background image

Insert house wires through center

hole.Install the mounting plate to the

outlet box.Use only the screws pro-

vided with the outlet box.

38

Hang motor from hook on the

mounting plate. Use the closed

hole.Place receiver in the hanging

plate.

40

Separate from bracket.

34

Remove screws with wrench. 

33

Make wiring connections as indicated above.

White from fan to white from remote marked

N. Blue from fan to blue from remote marked

light. Black from fan to Black from remote

marked L. White from house to white from

remote marked AC N . Black from house to

Black from remote marked AC L. Connect all

green ground wires to Ground wire from

House.

white

black

42

Set dip switches on the Remote Transmitter and Remote

Receiver to the same settings.  This must be done so the

units will communcate properly.  If you have other fans you

can set to control from one transmitter by setting both

receivers the same as the transmitter.  If you have more

than one fan with remote.  You can set the dip switches to

different positiosns to have seperate control.

Remote Transmitter Dip swtiches

Remote Receiver Dip switches

41

Place receiver into  the lower hang-

ing plate.

39

Remove the yoke from the motor by

removing 6 screws. 

31

Remove the yoke from the mounting

plate.

32

Stick the plastic plate onto the hang-

ing bracket aligning the holes as

shown above.

35

Thread safety cable through center

hole of the mounting plate. Thread

your house wires through center hole

also.These will be needed for wiring

of the fan.

36

For Canadian installation and for USA fan and

light kit combinations over 35 lbs, in both flush

and downrod mode the safety cable must be

installed into the house structure beams using

the 3” lag screws provided.  Make sure that

when the safety cable is fully extended the

leadwires are longer than the cable and no

stress is placed on the leadwires.

37

Safety cable installation

Safety Cable

Lag Screw

Lag Screw

Safety Cable

Washer

Lock Washer

Содержание 5MHR52RBD-L Series

Страница 1: ...Owner s Manual Ceiling Fan Installation Instructions For 5MHR52RBD L Series Fans READ AND SAVE THESE INSTRUCTIONS Total fan weight with lights ...

Страница 2: ... can be reached from a tub or shower The combustion airflow needed for safe operation of fuel burning equipment may be affected by this unit s operation Follow the heating equip ment manufacturer s guideline safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local...

Страница 3: ...he safety cable is fully extended the lead wires are longer than the cable and no stress is placed on the lead wires 10 Safety cable installation Safety Cable Lag Screw safety cable 3 lag screw lock washer washer Install remote receiver by sliding into opening in the Mounting bracket Make sure that the dip switches on the Transmitter and the Receiver are set to the same position See Fig 38 for rem...

Страница 4: ...ction of arrow 26 Install 3 x 40 watt incandescent candelabra bulbs Bulbs included WARNING Over lamping the fan will result in the fan lights shutting down until the proper wattage of bulbs are installed Reset the lights by turning off the wall switch breaker or by remote Replace bulbs with the correct wattage bulbs turn the power on 25 20 Align seams as shown above Blades not shown 21 Align the a...

Страница 5: ...ting both receivers the same as the transmitter If you have more than one fan with remote You can set the dip switches to different positiosns to have seperate control Remote Transmitter Dip swtiches Remote Receiver Dip switches 41 Place receiver into the lower hang ing plate 39 Remove the yoke from the motor by removing 6 screws 31 Remove the yoke from the mounting plate 32 Stick the plastic plat...

Страница 6: ...LD INSTALL WALL MOUNT INSTALL Remove cover by snaping off from top or bot tom Remove battery cover Install 12V battery into wall remote Duracell MN21 Eveready A23 GP 23A all 12V Attach cover of remote by plac ing over buttons and snap the battery cover in place 47 46 Refer back to step 22 for blade and light kit installation Tighten all screws 45 Install by placing over screws and twisting Reinsta...

Страница 7: ...om bright to dim to bright until button is released Light will maintain last setting if turned off FORWARD REVERSE Depress rev button allow a few seconds for remote to change rotation direction with fan running HIGH SPEED MEDIUM SPEED LOW SPEED FAN OFF SETTING Turns fan off only FAN REVERSE Press once to change direction of the fan Fanmust be running to reverse LIGHT ON OFF SET TING AND DIMMER Pre...

Страница 8: ...pplied between the blade and blade holder at the screw closest to the motor To adjust a blade tip up insert washer not supplied between the blade and blade holder at the two screws farthest from the motor Reverse the posi tion of the washer if blades mount from top of blade 6 If blade wobble is still noticeable interchanging two adjacent side by side blades can redistrib ute the weight and possibl...

Отзывы: