background image

  Trouble Shooting

If you have difficulty operating your new ceiling fan, it may be the result of incorrect assembly, installation, 

or wiring. In some cases, these installation errors may be mistaken for defects. If you experience any faults, 

please check this Trouble Shooting Chart. If a problem cannot be remedied, or you are experiencing difficulty in 

installation, please call our Customer Service Center at the 

number printed on your parts list insert sheet. 

Warning

:  Before  servicing  or  cleaning  unit,  Switch  power  off  at  Service  panel  and  lock  service  disconnecting 

means to prevent power from being switched on accidentally.  When the service disconnecting means cannot be 

locked, securely fasten a prominent warning device, such  as a tag, to the service panel.

1.Check main and branch circuit fuses or circuit breakers.

2.Check line wire connections to fan and switch wire connections in switch housing.

CAUTION

: Make sure main power is turned off.

3.If this fan uses manual forward/reverse switch, make sure the switch is pushed firmly 

either way. Fan will not operate when switch is in the middle.

4.If this fan uses remote controller, make sure dip switches are setting properly and make 

sure battery is effective.

 

1.Check to make sure all screws in motor housing are snug (not over tightened).

2.Check to make sure the screws which attach the fan blade holder to the motor are tight.

3.Check to make sure wire nut connectors in switch housing are not rattling against each 

other or against the interior wall of the switch housing.

CAUTION

:  Make sure main power is turned off before entering switch housing.

4.Check to be sure light bulb is tight in socket and not touching the glass shade.

5.Some fan motors are sensitive to signals from Solid State variable speed controls.  

6.Allow "break-in" period of 24 hours.  Most noises associated with a new fan will disappear 

after this period.

1.If  this  is  a  downrod  mount  fan,  make  sure  that  the  ridge  of  the  canopy  engages  the 

notch in the downrod ball.

2.Make  sure  that  canopy,  mounting  bracket  or  mounting  plate  are  tightened  securely  to 

ceiling junction box and junction box is mounted firmly to ceiling joist.

3.Check that all blades are screwed firmly into blade holders.

4.Check that all blade holders are tightened securely to motor.

5.Most fan wobble problems are caused when blade levels are unequal. Check this level by 

selecting a point on the ceiling above the tip of one of the blades. Measure this distance 

from blade tip to ceilng. Keeping measure within 1/8", rotate the fan until the next blade 

is  positioned  for  measurement.  Repeat  for  each  blade.  If  all  blade  levels  are  not  equal, 

you can adjust blade levels by the following procedure. To adjust a blade tip down, insert 

a washer (not supplied) between the blade and blade holder at the screw closest to the 

motor. To adjust a blade tip up, insert washer (not supplied) between the blade and blade 

holder at the two screws farthest from the motor.  Reverse the position of the washer if 

blades mount from top of blade.

6.If blade wobble is still noticeable, interchanging two adjacent (side by side) blades can 

redistribute the weight and possibly result in smoother operation.

1.Check blue wire from fan to make sure it is connected to hot wire from house.

2.Check for loose or disconnected wires in fan switch housing.

3.Check for loose or disconnected wires in light kit.

4.Check for faulty light bulb and make sure bulb is tight in socket.

5.Remove light kit and check the plug connections if it is connected with plugs.

6.If this fan uses remote controller, make sure dip switches are setting properly and make 

sure battery is effective. 

 

CAUTION

:    Make  sure  main  power  is  turned  off  before  entering  switch  housing  and/or 

canopy.

WARNING

Over lamping the fan will result in the fan lights shutting down until the proper 

wattage of bulbs are installed. Reset the lights by turning off, replace bulbs with the correct 

wattage bulbs, Turn power on.

                                          

2. If fan sounds noisy:

3. If fan wobbles:

4. If light does not work:

1. If fan does not start:

Trouble

Suggested Remedy

Содержание 5MFR52 D Series

Страница 1: ... vous avez besoin d aide pour l installation des pièces de remplacement ou si vous avez des questions concernant notre garantie veuillez contacter notre service après vente If you need installation assistance replacement parts or have questions regarding our warranty please call our customer care center NEED HELP NECESITA AYUDA AVEZ VOUS BESOIN D AIDE Please do not return this product to the store...

Страница 2: ...onnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Be cautious read all instructions and safety information before installing your new fan Review the accompanying assembly diagrams When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities Make sure the installation site you choose allows the ...

Страница 3: ...re connections the wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box The splices after being made should be turned upward and pushed carefully up into the outlet box For Canadian installation and for USA fan and light kit combinations over 35 lbs in both flush and...

Страница 4: ...e with the screws on light pan and twist counterclockwise till tight Re nstall the screw which removed in step 21 Tighten all screws securely 28 Place scene over light fixture aligning the holes with screw holes on light fixture as shown 27 Install finial to secure the glass 22 Connect white wire from fan to white wire from light fixture then connect blue wire from fan to black wire from light fix...

Страница 5: ...Hang tighten finial to secure the glass Reverse feature of this fan is controlled by a switch located on top of the fan body Turn off the fan and reverse the fan by slipping the switch This will reverse the direction of the fan blades 37 Remove battery cover Install 12V battery into wall remote Duracell MN21 Eveready A23 GP 23A all 12V Attach cover of remote by placing over buttons and snap the ba...

Страница 6: ...e light will cycle from bright to dim to bright until button is released Light will maintain last setting if turned off FAN SPEED Depress l dot for low speed 2 dots for medium or 3 dots for high To turn fan off press square HIGH SPEED MEDIUM SPEED LED LIGHT LOW SPEED FA N O F F S E TT I N G Turns fan off only LIGHT ON OFF SETTING A N D D I M M E R P r e s s and hold to dim light infinitively ...

Страница 7: ...at the ridge of the canopy engages the notch in the downrod ball 2 Make sure that canopy mounting bracket or mounting plate are tightened securely to ceiling junction box and junction box is mounted firmly to ceiling joist 3 Check that all blades are screwed firmly into blade holders 4 Check that all blade holders are tightened securely to motor 5 Most fan wobble problems are caused when blade lev...

Страница 8: ...Aug 2010 ...

Отзывы: