 8

 7

Thread  the  leadwires  and 

safety  cable  through  the 

downrod.

P l a c e   y o k e   c o v e r   o v e r 

downrod as shown. 

 9

Insert downrod into the yoke on top 

of  fan  body.    Align  the  hole  in  the 

downrod with the hole in the yoke.  

Insert  cross  pin  through  yoke  and 

downrod until point appears on the 

other side. 

10

Install keeper pin.

11

Tighten  the  2  set  screws  on 

the yoke, once the down rod 

is in place.

13

Hang  assembled  fan  from  the  mounting 

bracket  installed  to  ceiling  in  previous 

step.  Make  sure  the  fan  is  hanging 

straight.  Rotate  fan  until  the  tab  on  the 

Mounting bracket engages the slot on the 

Downrod  Ball. 

This  must  be  done  to 

prevent  the  fan  body  from  rotating 

when the blades are in motion.

Black

Black

White

White

Blue

Grounded/

Green

Receiver

17

Make  wiring  connections  as  indicated  above.  

White from fan to white from remote marked 

N.  Blue from fan to blue from remote marked 

light.  Black  from  fan  to  Black  from  remote 

marked  L.  White  from  house  to  white  from 

remote  marked  AC  N  .  Black  from  house  to 

Black  from  remote  marked  AC  L.  Connect  all 

green  ground  wires  to  Grounded  wire  from 

House.

18

Make  wire  connections  to  power  source  using 

wire  nuts  provided.    Make  sure  that  no  filiments 

are outside of the wirenut. After making the wire 

connections,  the  wires  should  be  spread  apart 

with the grounded conductor and the equipment-

grounding  conductor  on  one  side  of  the  outlet 

box and ungrounded conductor on the other side 

of  the  outlet  box.  The  splices  after  being  made 

should be turned upward and pushed carefully up 

into the outlet box. 

For Canadian installation and for USA fan and light 

kit  combinations  over  35  lbs,  in  both  flush  and 

downrod  mode  the  safety  cable  must  be  installed 

into  the  house  structure  beams  using  the  3”  lag 

screws,washers, and lock washers. provided.  Make 

sure  that  when  the  safety  cable  is  fully  extended 

the  leadwires  are  longer  than  the  cable  and  no 

stress is placed on the leadwires.

14

Lag screw

Safety cable

Washer

Lock washer

Lag screw

Safety cable

Safety cable installation

12

 

M a k e   s u r e   t h e   s t u d s 

protruding  from  the  bottom 

of  the  Mounting  bracket  are 

installed  with  threads  all  the 

way through the bracket. 

15

Set  dip  switches  on  the  Remote  Transmitter 

and  Remote  Receiver  to  the  same  settings.  

T h i s   m u s t   b e   d o n e   s o   t h e   u n i t s   w i l l 

communcate properly.  If you have other fans 

you  can  set  to  control  from  one  transmitter 

by  setting  both  receivers  the  same  as  the 

transmitter.    If  you  have  more  than  one  fan 

with remote.  You can set the dip switches to 

different positiosns to have seperate control.

Remote transmitter dip switch

Remote receiver dip switch

16

Install  remote  receiver  into 

the mounting bracket.

Содержание 5MFR52 D Series

Страница 1: ... vous avez besoin d aide pour l installation des pièces de remplacement ou si vous avez des questions concernant notre garantie veuillez contacter notre service après vente If you need installation assistance replacement parts or have questions regarding our warranty please call our customer care center NEED HELP NECESITA AYUDA AVEZ VOUS BESOIN D AIDE Please do not return this product to the store...

Страница 2: ...onnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Be cautious read all instructions and safety information before installing your new fan Review the accompanying assembly diagrams When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities Make sure the installation site you choose allows the ...

Страница 3: ...re connections the wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box The splices after being made should be turned upward and pushed carefully up into the outlet box For Canadian installation and for USA fan and light kit combinations over 35 lbs in both flush and...

Страница 4: ...e with the screws on light pan and twist counterclockwise till tight Re nstall the screw which removed in step 21 Tighten all screws securely 28 Place scene over light fixture aligning the holes with screw holes on light fixture as shown 27 Install finial to secure the glass 22 Connect white wire from fan to white wire from light fixture then connect blue wire from fan to black wire from light fix...

Страница 5: ...Hang tighten finial to secure the glass Reverse feature of this fan is controlled by a switch located on top of the fan body Turn off the fan and reverse the fan by slipping the switch This will reverse the direction of the fan blades 37 Remove battery cover Install 12V battery into wall remote Duracell MN21 Eveready A23 GP 23A all 12V Attach cover of remote by placing over buttons and snap the ba...

Страница 6: ...e light will cycle from bright to dim to bright until button is released Light will maintain last setting if turned off FAN SPEED Depress l dot for low speed 2 dots for medium or 3 dots for high To turn fan off press square HIGH SPEED MEDIUM SPEED LED LIGHT LOW SPEED FA N O F F S E TT I N G Turns fan off only LIGHT ON OFF SETTING A N D D I M M E R P r e s s and hold to dim light infinitively ...

Страница 7: ...at the ridge of the canopy engages the notch in the downrod ball 2 Make sure that canopy mounting bracket or mounting plate are tightened securely to ceiling junction box and junction box is mounted firmly to ceiling joist 3 Check that all blades are screwed firmly into blade holders 4 Check that all blade holders are tightened securely to motor 5 Most fan wobble problems are caused when blade lev...

Страница 8: ...Aug 2010 ...

Отзывы: