background image

© 2013 Monte Carlo Fan Company

8/13/2013

6

Install 3 screws to install light pan.

32

Connect plug from fan to switch

house plug. Be sure plugs connection

snap together completely. 

29

Install by twisting clockwise, add 1

screw removed step 27 to switch

housing plate. Tighten the 3 screws

securely.

28

Connect white wire from fan to white

wire from light fixture. Then plug

blue wire from fan to black wire from

light fixture.

31

Loosen the pre installed screws of

switch housing plate. Save removed

screw for use later.

Install a JD 75 watt halogen bulb, bulb in-

cluded.

Caution

: Do not replace bulb until it cools

down.   

WARNING:

Over lamping the fan will re-

sult in the fan lights shutting down until

the proper wattage of bulbs are installed.

Reset the lights by turning off the wall

switch, breaker,or by remote. Replace bulbs

with the correct wattage bulbs, turn the

power on.

33

30

Attach glass by locating dimples in

light fixture with the groves in glass

and twisting clockwise till tight.

34

Setting the reverse switch in the left hand

side will result in downward airflow and set-

ting the switch in the right hand side will re-

sult in upward airflow.

Note

: Reverse switch must be set either

completely LEFT or completely Right for fan

to function. If the reverse switch is set in the

middle position, fan will not operate. 

35

Reverse switch

Left hand side

(Forward)

Right hand side

(Reverse)

Loosen 2 screws and remove 1 screw

from motor plate. Save removed

screw for use later.

27

Содержание 5DI52XXD-L Series

Страница 1: ...card and retain as your proof of purchase DATE OF PURCHASE MODEL NUMBER RETAILER NAME RETAILER ADDRESS To register your fixture please visit our website www montecarlofans com 5DI52XXD 5DI52XXD L Series Fan Total fan weight with light UL Model No 5DI52 8 5 kgs 18 7 lbs ...

Страница 2: ...Use Mounting Screws Provided With The Outlet Box CAUTION For Compliance with Local Codes and Regulations If Installing The Secondary Support Safety Cable in the U S Do Not Re move Knockouts In The Outlet Box Mount the secondary support safety cable through the reserved nail screw hole on the outlet box to the building structure or the ceiling joist WARNING To reduce the risk of personal injury do ...

Страница 3: ...tlet box ensure the outlet box is securley fastened by at least two points to a structural ceiling member a loose box will cause the fan to wabble Use only the screws provided with the outlet box 3 2 1 Loosen the 2 set screws till you can not feel them on inside of yoke Note If install fan on vaulted ceiling make sure open end of mounting bracket is installed facing the higher point of the ceiling...

Страница 4: ...r Hot wire from house Connect White wire from Fan to White Neutral wire from house Connect Ground leads from mounting bracket and downrod to Ground lead from house Refer to Safety Tips section of manual 14 For Canadian installation and for USA fan and light kit combinations over 35 lbs in both flush and downrod modes the safety cable must be installed into the house structure beams using 3 lag scr...

Страница 5: ...screws from hardware pack and install one on each side of bracket to match the L slot screw holes in canopy Keep 2 screws for later use 22 Make wire connections to power source using wire nuts provided Make sure that no filiments are outside of the wirenut After making the wire connections the wires should be spread apart with the grounded con ductor and the equipment grounding conductor on one si...

Страница 6: ...he fan will re sult in the fan lights shutting down until the proper wattage of bulbs are installed Reset the lights by turning off the wall switch breaker or by remote Replace bulbs with the correct wattage bulbs turn the power on 33 30 Attach glass by locating dimples in light fixture with the groves in glass and twisting clockwise till tight 34 Setting the reverse switch in the left hand side w...

Страница 7: ...ure this distance from blade tip to ceilng Keeping measure within 1 8 rotate the fan until the next blade is posi tioned for measurement Repeat for each blade If all blade levels are not equal you can ad just blade levels by the following procedure To adjust a blade tip down insert a washer not supplied between the blade and blade holder at the screw closest to the motor To adjust a blade tip up i...

Страница 8: ...Apr 2013 May 2013 CUL requirement Aug 2013 dual mount ...