© 2013 Monte Carlo Fan Company

8/13/2013

2

WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: READ

AND SAVE THESE INSTRUCTIONS

Installation work and electrical wiring must be done by qualified person(s) in accordance with applicable codes and standards (ANSI/NFPA 70-1999), including
fire-rated construction.

Use this unit only in the manner intended by the manufacturer.  If you have  any questions contact the manufacturer.

After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conductor on one side of the
outlet box and ungrounded conductor on the other side of the outlet box. The splices, after being made, should be turned upward and pushed carefully up
into the outlet box.

WARNING

: Before you begin installing the fan, servicing or cleaning unit, Switch power off at Service panel and lock service disconnecting means to prevent

power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a
tag, to the service panel.

Be cautious! Read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.

When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7 feet from the floor to the
trailing edge of the blade.

WARNING

: To Reduce The Risk Of Fire, Electric Shock, or Personal Injury, Mount To Outlet Box Marked “Acceptable for Fan Support of

15.9 kg (35 lbs) or less” And Use Mounting Screws Provided With The Outlet Box.

CAUTION: 

For Compliance with Local Codes and Regulations, If Installing The Secondary Support Safety Cable in the U.S., Do Not Re-

move Knockouts In The Outlet Box. Mount the secondary support safety cable through the reserved nail/screw hole on the outlet box to
the building structure (or the ceiling joist).

WARNING

: To reduce the risk of personal injury, do not bend blade holders during installation to motor, balancing or during cleaning.  Do not insert foreign

object between rotating blades.

Attach the mounting bracket using only the hardware supplied with the outlet box.

WARNING

: To reduce the risk of fire or electric shock, this fan must be installed with an isolating wall control/switch.

WARNING:

To reduce the risk of fire or electric shock, do not use this fan with any solid state fan speed control device, or variable speed control.

If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application.

Never place a switch where it can be reached from a tub or shower.

The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heating equipment manufac-
turer’s guideline safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigera-
tion and Air Conditioning Engineers (ASHRAE) and the local code authorities.

CAUTION

: To Reduce the Risk of Electric Shock, Disconnect the electrical supply circuit to the fan before installing the light kit. 

All set screws must be checked and tightened where necessary before installation. 

Customer Service

800-969-3347

Customer Service Center

7400 Linder Ave.

Skokie, IL 60077

www.montecarlofans.com

Tools Required for Assembly (not included): Electrical Tape, Phillips Screwdriver, Pliers, Safety Glasses,

Stepladder and Wire Strippers.

Содержание 5DI52XXD-L Series

Страница 1: ...card and retain as your proof of purchase DATE OF PURCHASE MODEL NUMBER RETAILER NAME RETAILER ADDRESS To register your fixture please visit our website www montecarlofans com 5DI52XXD 5DI52XXD L Series Fan Total fan weight with light UL Model No 5DI52 8 5 kgs 18 7 lbs ...

Страница 2: ...Use Mounting Screws Provided With The Outlet Box CAUTION For Compliance with Local Codes and Regulations If Installing The Secondary Support Safety Cable in the U S Do Not Re move Knockouts In The Outlet Box Mount the secondary support safety cable through the reserved nail screw hole on the outlet box to the building structure or the ceiling joist WARNING To reduce the risk of personal injury do ...

Страница 3: ...tlet box ensure the outlet box is securley fastened by at least two points to a structural ceiling member a loose box will cause the fan to wabble Use only the screws provided with the outlet box 3 2 1 Loosen the 2 set screws till you can not feel them on inside of yoke Note If install fan on vaulted ceiling make sure open end of mounting bracket is installed facing the higher point of the ceiling...

Страница 4: ...r Hot wire from house Connect White wire from Fan to White Neutral wire from house Connect Ground leads from mounting bracket and downrod to Ground lead from house Refer to Safety Tips section of manual 14 For Canadian installation and for USA fan and light kit combinations over 35 lbs in both flush and downrod modes the safety cable must be installed into the house structure beams using 3 lag scr...

Страница 5: ...screws from hardware pack and install one on each side of bracket to match the L slot screw holes in canopy Keep 2 screws for later use 22 Make wire connections to power source using wire nuts provided Make sure that no filiments are outside of the wirenut After making the wire connections the wires should be spread apart with the grounded con ductor and the equipment grounding conductor on one si...

Страница 6: ...he fan will re sult in the fan lights shutting down until the proper wattage of bulbs are installed Reset the lights by turning off the wall switch breaker or by remote Replace bulbs with the correct wattage bulbs turn the power on 33 30 Attach glass by locating dimples in light fixture with the groves in glass and twisting clockwise till tight 34 Setting the reverse switch in the left hand side w...

Страница 7: ...ure this distance from blade tip to ceilng Keeping measure within 1 8 rotate the fan until the next blade is posi tioned for measurement Repeat for each blade If all blade levels are not equal you can ad just blade levels by the following procedure To adjust a blade tip down insert a washer not supplied between the blade and blade holder at the screw closest to the motor To adjust a blade tip up i...

Страница 8: ...Apr 2013 May 2013 CUL requirement Aug 2013 dual mount ...

Отзывы: