WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING

READ AND SAVE THESE INSTRUCTIONS

Installation work and electrical wiring must be done by qualified person(s) in accordance with applicable codes and standards (ANSI/NFPA
70-1999), including fire-rated construction.

Use this unit only in the manner intended by the manufacturer.  If you have  any questions contact the manufacturer.

After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conductor
on one side of the outlet box and ungrounded conductor on the other side of the outlet box. The splices, after being made, should be
turned upward and pushed carefully up into the outlet box.

WARNING

: Before you begin installing the fan, servicing or cleaning unit, Switch power off at Service panel and lock service disconnecting

means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.

Be cautious! Read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.

When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7 feet
from the floor to the trailing edge of the blade.

WARNING

: To Reduce The Risk Of Fire, Electric Shock, or Personal Injury, Mount To Outlet Box Marked “Acceptable for Fan Support of

15.9 kg (35 lbs) or less” And Use Mounting Screws Provided With The Outlet Box.

WARNING

: To reduce the risk of personal injury, do not bend blade holders during installation to motor, balancing or during cleaning.  Do

not insert foreign object between rotating blades.

Attach the mounting bracket using only the hardware supplied with the outlet box.

WARNING

: To reduce the risk of fire or electric shock, this fan must be installed with an isolating wall control/switch.

WARNING

: To reduce the risk of fire or electric shock, this fan should only be used with fan speed control part no. BJX1514AST manufac-

tured by Air Cool Industrial Co., Ltd.

WARNING: 

To reduce the risk of fire or electric shock, do not use this fan with any solid state fan speed control device, or variable speed

control.

If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application.

Never place a switch where it can be reached from a tub or shower.

The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heating
equipment manufacturer’s guideline safety standards such as those published by the National Fire Protection Association (NFPA), and the
American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.

CAUTION

: To Reduce the Risk of Electric Shock, Disconnect the electrical supply circuit to the fan before installing the light kit. 

All set screws must be checked and tightened where necessary before installation. 

Cutomer Service

800-969-3347

Customer Service Center

7400 Linder Ave.

Skokie, IL 60077

www.montecarlofans.com

Tools Required for Assembly (not included): Electrical Tape, Phillips Screwdriver, Pliers, Safety Glasses,

Stepladder and Wire Strippers.

Содержание 5DCR52 Series

Страница 1: ... MODEL NUMBER RETAILER NAME RETAILER ADDRESS To register your fixture please visit our website www montecarlofans com 5DCR52XX Series Fan Total fan weight UL Model No AC 560DC 10 kgs 22 lbs Warning This fan uses dimmable remote controller Do not install light kit with SBCFL Self Ballasted Compact Fluorescent Lamp on this fan ...

Страница 2: ... Box Marked Acceptable for Fan Support of 15 9 kg 35 lbs or less And Use Mounting Screws Provided With The Outlet Box WARNING To reduce the risk of personal injury do not bend blade holders during installation to motor balancing or during cleaning Do not insert foreign object between rotating blades Attach the mounting bracket using only the hardware supplied with the outlet box WARNING To reduce ...

Страница 3: ...framing member of a building and or may be mounted to an outlet box marked acceptable for fan sup port of of 16 kg 35 lbs or less Most outlet boxes commonly used for the support of lummi naires may not be acceptable for fan support and may need to be replaced Consult a quali fied electrician if in doubt 2 OUTLET BOX METHOD Loosen the 2 set screws You should be able to put your downrod into the yok...

Страница 4: ...int 3 of safety tips 14 House Fan Black White Green Black White Green downrod Green Bracket Place blade onto blade holder Install 3 screws and washers per blade and tighten securely Repeat for all 5 blades 18 Place the gasket onto the blade bracket as shown above 16 Place blade onto blade bracket with gasket 17 For Canadian installation and for USA fan and light kit combinations over 35 lbs in bot...

Страница 5: ...te and save 22 Install the switch housing plate by aligning the 2 screws with the 2 key slot holes on the plate and twist to lock into place Install the 1 screw removed and tighten the other 2 screws securely 21 Loosen 2 screws and remove 1 screw and save 20 Attach blade assembly to motor using the motor screws and washers provided Tighten screws securely 19 ...

Страница 6: ...ns can not be controlled separately 2 The fan can remember the running setting before power failure or cut off 3 If the new fan runs after connected to power it may be due to the fan remembering the previous running setting in the factory during the QC process push stop key on transmitter twice to stop Operation Installation 1 Remove the battery cover and the battery from the transmitter you will ...

Страница 7: ...ce quickly To turn offpress once quickly while light is on To dim light hold down button light dimmer The light will cycle from bright to dim to bright until button is released Light willmaintain last setting if turned off You can see the percentage on the display screen NOTE If you have more than 1 fan with a remote you will have to change the DIP switch settings located above the battery of the ...

Страница 8: ... by the following procedure To adjust a blade tip down insert a washer not supplied between the blade and blade holder at the screw closest to the motor To adjust a blade tip up insert washer not supplied between the blade and blade holder at the two screws farthest from the motor Reverse the position of the washer if blades mount from top of blade 6 If blade wobble is still noticeable interchangi...

Страница 9: ...Apr 2012 New format Sep 5 2012 Up date about learn function setting ...