Installation work and electrical wiring must be done by qualified person(s) in accordance with applicable codes and standards (ANSI/NFPA 

70-1999), including fire-rated construction.
Use this unit only in the manner intended by the manufacturer.  If you have  any questions contact the manufacturer.
After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conduc-

tor on one side of the outlet box and ungrounded conductor on the other side of the outlet box. The splices, after being made, should be 

turned upward and pushed carefully up into the outlet box.

WARNING:

 Before you begin installing the fan, servicing or cleaning unit, Switch power off at Service panel and lock service disconnecting 

means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a 

prominent warning device, such as a tag, to the service panel.
Be cautious! read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.
When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7 feet 

from the floor to the trailing edge of the blade.

WARNING:

 To Reduce The Risk Of Fire, Electric Shock, or Personal Injury, Mount To Outlet Box Marked “Acceptable for Fan Support of 15.9 

kg (35 lbs) or less” And Use Mounting Screws Provided With The Outlet Box.

WARNING:

 To reduce the risk of personal injury, do not bend blade holders during installation to motor, balancing or during cleaning.  Do 

not insert foreign object between rotating blades.
Attach the mounting bracket using only the hardware supplied with the outlet box.

WARNING:

 To reduce the risk of fire or electric shock, this fan must be installed with an isolating wall control/switch.

WARNING:

 To reduce the risk of fire or electric shock, do not use this fan with any solid state fan speed control device, or variable speed 

control.
If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application.
Never place a switch where it can be reached from a tub or shower.
The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heating 

equipment manufacturer’s guideline safety standards such as those published by the National Fire Protection Association (NFPA), and the 

American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.

CAUTION:

 To Reduce the Risk of Electric Shock, Disconnect the electrical supply circuit to the fan before installing the light kit. 

All set screws must be checked and tightened where necessary before installation. 

Cautions and Warnings

WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVETHE FOLLOWING

 READ AND SAVE THESE INSTRUCTIONS

Cutomer Service

800-969-3347

Customer Service Center

7400 Linder Ave.

Skokie, IL 60077

www.montecarlofans.com

Tools Required for Assembly (not included): Electrical Tape, Phillips Screwdriver, Pliers, Safety Glasses, Steplad-

der and Wire Strippers

Содержание 5CQ52 Series

Страница 1: ...UL Model No AC 552 Total fan weight DATE OF PURCHASE MODEL NUMBER RETAILER NAME RETAILER ADDRESS Attach sales receipt to this card and retain as your proof of purchase To register your fixture please visit our website www montecarlofans com 8 49 kgs 18 68 lbs ...

Страница 2: ...bs or less And Use Mounting Screws Provided With The Outlet Box WARNING To reduce the risk of personal injury do not bend blade holders during installation to motor balancing or during cleaning Do not insert foreign object between rotating blades Attach the mounting bracket using only the hardware supplied with the outlet box WARNING To reduce the risk of fire or electric shock this fan must be in...

Страница 3: ...ws provided with the outlet box must support 35 lbs Before attaching fan to outlet box ensure the outlet box is securely fastened by at least two points to a structural ceiling member a loose box will cause the fan to wobble Remove the two outlet box screws provided with the box aligning the holes of the mounting bracket with the holes of the outlet box Re install the 2 outlet box screws securely ...

Страница 4: ...equipment grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box The splices after being made should be turned upward and pushed carefully up into the outlet box For Canadian installation and for USA fan and light kit combinations over 35 lbs in both flush and downrod mode the safety cable must be installed into the house structure beams usin...

Страница 5: ...l 25 Make wire connections to power source using wire nuts provided Make sure that no filiments are outside of the wirenut After making the wire connections the wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box The splices after being made should be turned upward ...

Страница 6: ...e plate on motor Save screw for later use 31 Place switch housing over wire harness from motor Attached switch housing on to the plate on motor aligning the keyhole slots with the preassembled screws on the plate Twist clockwise till lock Install the screw removed in step 30 Tighten all screws securely 32 Connect plug from fan to plug from switch housing Make sure the plugs are hooked together 34 ...

Страница 7: ...7 36 Install switch housing cover with the screws removed in step 34 Setting the reverse switch in the left hand side will result in downrod airflow and setting the switch in the right hand side will result in upward airflow Reverse switch ...

Страница 8: ...od of 24 hours Most noises associated with a new fan will disappear after this period 1 If this is a downrod mount fan make sure that the ridge of the canopy engages the notch in the downrod ball 2 Make sure that canopy mounting bracket or mounting plate are tightened securely to ceiling junction box and junction box is mounted firmly to ceiling joist 3 Check that all blades are screwed firmly int...

Страница 9: ...Feb 2012 New format ...

Отзывы: