background image

2/6/2012

© 2011 Monte Carlo Fan Company

4

10

Install keeper pin.

11

Tighten 2 set screws on yoke 

once the down rod is in place.

13

Hang assembled fan from the mounting 

bracket installed to ceiling in previous 

step. Make sure the fan is hanging 

straight. Rotate fan until the tab on 

the Mounting bracket engages the slot 

on the Downrod Ball. 

This must be 

done to prevent the fan body from 

rotating when the blades are in 

motion.

15

Make wiring connections as indicated 

above.  Connect black and blue wire from 

fan to Black or (Hot) wire from house.  

Connect White wire from Fan to White 

(Neutral) wire from house.  Connect 

Ground leads from mounting bracket and 

downrod to Ground lead from house.  Refer 

to Safety Tips section of manual.

16

Make wire connections to power source using 

wire  nuts  provided.    Make  sure  that  no  filiments 

are outside of the wirenut. After making the wire 

connections, the wires should be spread apart 

with the grounded conductor and the equipment-

grounding conductor on one side of the outlet 

box and ungrounded conductor on the other side 

of the outlet box. The splices after being made 

should be turned upward and pushed carefully up 

into the outlet box. 

For Canadian installation and for USA fan and light 

kit combinations over 35 lbs, in both flush and 

downrod mode the safety cable must be installed 

into the house structure beams using the 3” lag 

screws,washers, and lock washers. provided.  Make 

sure that when the safety cable is fully extended 

the leadwires are longer than the cable and no 

stress is placed on the leadwires.

14

Lag screw

Safety cable

Washer

Lock washer

Lag screw

Safety cable

Safety cable installation

17

Lift canopy up, aligning its keyhole 

slots with the preassembled screw on 

mounting bracket and twist clockwise till 

lock. Install the screw removed in step 

12. Tighten all screws securely. 

12

 

L o o s e n   t w o   p r e a s s e m b l e d 

screws across from each other 

corresponding to the open slotted 

holes on the canopy upper rim and 

remove the other two screws from 

mounting bracket. Keep screws for 

later use.

G o   t o   s t e p   2 7   t o 

finish installation

Supply

circuit

Содержание 5CQ52 Series

Страница 1: ...UL Model No AC 552 Total fan weight DATE OF PURCHASE MODEL NUMBER RETAILER NAME RETAILER ADDRESS Attach sales receipt to this card and retain as your proof of purchase To register your fixture please visit our website www montecarlofans com 8 49 kgs 18 68 lbs ...

Страница 2: ...bs or less And Use Mounting Screws Provided With The Outlet Box WARNING To reduce the risk of personal injury do not bend blade holders during installation to motor balancing or during cleaning Do not insert foreign object between rotating blades Attach the mounting bracket using only the hardware supplied with the outlet box WARNING To reduce the risk of fire or electric shock this fan must be in...

Страница 3: ...ws provided with the outlet box must support 35 lbs Before attaching fan to outlet box ensure the outlet box is securely fastened by at least two points to a structural ceiling member a loose box will cause the fan to wobble Remove the two outlet box screws provided with the box aligning the holes of the mounting bracket with the holes of the outlet box Re install the 2 outlet box screws securely ...

Страница 4: ...equipment grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box The splices after being made should be turned upward and pushed carefully up into the outlet box For Canadian installation and for USA fan and light kit combinations over 35 lbs in both flush and downrod mode the safety cable must be installed into the house structure beams usin...

Страница 5: ...l 25 Make wire connections to power source using wire nuts provided Make sure that no filiments are outside of the wirenut After making the wire connections the wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box The splices after being made should be turned upward ...

Страница 6: ...e plate on motor Save screw for later use 31 Place switch housing over wire harness from motor Attached switch housing on to the plate on motor aligning the keyhole slots with the preassembled screws on the plate Twist clockwise till lock Install the screw removed in step 30 Tighten all screws securely 32 Connect plug from fan to plug from switch housing Make sure the plugs are hooked together 34 ...

Страница 7: ...7 36 Install switch housing cover with the screws removed in step 34 Setting the reverse switch in the left hand side will result in downrod airflow and setting the switch in the right hand side will result in upward airflow Reverse switch ...

Страница 8: ...od of 24 hours Most noises associated with a new fan will disappear after this period 1 If this is a downrod mount fan make sure that the ridge of the canopy engages the notch in the downrod ball 2 Make sure that canopy mounting bracket or mounting plate are tightened securely to ceiling junction box and junction box is mounted firmly to ceiling joist 3 Check that all blades are screwed firmly int...

Страница 9: ...Feb 2012 New format ...