  Trouble Shooting

If you have difficulty operating your new ceiling fan, it may be the result of incorrect assembly, installation, 

or wiring. In some cases, these installation errors may be mistaken for defects. If you experience any faults, 

please check this Trouble Shooting Chart. If a problem cannot be remedied, or you are experiencing difficulty in 

installation, please call our Customer Service Center at the 

number printed on your parts list insert sheet. 

Warning

: Before servicing or cleaning unit, Switch power off at Service panel and lock service disconnecting 

means to prevent power from being switched on accidentally.  When the service disconnecting means cannot be 

locked, securely fasten a prominent warning device, such  as a tag, to the service panel.

1.Check main and branch circuit fuses or circuit breakers.

2.Check line wire connections to fan and switch wire connections in switch housing.

CAUTION

: Make sure main power is turned off.

3.If this fan uses manual forward/reverse switch, make sure the switch is pushed firmly 

either way. Fan will not operate when switch is in the middle.

4.If this fan uses remote controller, make sure dip switches are setting properly and make 

sure battery is effective. 

1.Check to make sure all screws in motor housing are snug (not over tightened).

2.Check to make sure the screws which attach the fan blade holder to the motor are tight.

3.Check to make sure wire nut connectors in switch housing are not rattling against each 

other or against the interior wall of the switch housing.

CAUTION

: Make sure main power is turned off before entering switch housing.

4.Check to be sure light bulb is tight in socket and not touching the glass shade.

5.Some fan motors are sensitive to signals from Solid State variable speed controls.  

6.Allow "break-in" period of 24 hours. Most noises associated with a new fan will disappear 

after this period.

1.If this is a downrod mount fan, make sure that the ridge of the canopy engages the 

notch in the downrod ball.

2.Make sure that canopy, mounting bracket or mounting plate are tightened securely to 

ceiling junction box and junction box is mounted firmly to ceiling joist.

3.Check that all blades are screwed firmly into blade holders.

4.Check that all blade holders are tightened securely to motor.

5.Most fan wobble problems are caused when blade levels are unequal. Check this level by 

selecting a point on the ceiling above the tip of one of the blades. Measure this distance 

from blade tip to ceilng. Keeping measure within 1/8", rotate the fan until the next blade 

is positioned for measurement. Repeat for each blade. If all blade levels are not equal, 

you can adjust blade levels by the following procedure. To adjust a blade tip down, insert 

a washer (not supplied) between the blade and blade holder at the screw closest to the 

motor. To adjust a blade tip up, insert washer (not supplied) between the blade and blade 

holder at the two screws farthest from the motor. Reverse the position of the washer if 

blades mount from top of blade.

6.If blade wobble is still noticeable, interchanging two adjacent (side by side) blades can 

redistribute the weight and possibly result in smoother operation.

1.Check blue wire from fan to make sure it is connected to hot wire from house.

2.Check for loose or disconnected wires in fan switch housing.

3.Check for loose or disconnected wires in light kit.

4.Check for faulty light bulb and make sure bulb is tight in socket.

5.Remove light kit and check the plug connections if they are present.

6.If this fan uses remote controller, make sure dip switches are setting properly and make 

sure battery is effective. 

 

CAUTION

: Make sure main power is turned off before entering switch housing and/or 

canopy.

                                       

                               

2. If fan sounds noisy:

3. If fan wobbles:

4. If light does not work:

1. If fan does not start:

Trouble

Suggested Remedy

Содержание 5CQ52 Series

Страница 1: ...UL Model No AC 552 Total fan weight DATE OF PURCHASE MODEL NUMBER RETAILER NAME RETAILER ADDRESS Attach sales receipt to this card and retain as your proof of purchase To register your fixture please visit our website www montecarlofans com 8 49 kgs 18 68 lbs ...

Страница 2: ...bs or less And Use Mounting Screws Provided With The Outlet Box WARNING To reduce the risk of personal injury do not bend blade holders during installation to motor balancing or during cleaning Do not insert foreign object between rotating blades Attach the mounting bracket using only the hardware supplied with the outlet box WARNING To reduce the risk of fire or electric shock this fan must be in...

Страница 3: ...ws provided with the outlet box must support 35 lbs Before attaching fan to outlet box ensure the outlet box is securely fastened by at least two points to a structural ceiling member a loose box will cause the fan to wobble Remove the two outlet box screws provided with the box aligning the holes of the mounting bracket with the holes of the outlet box Re install the 2 outlet box screws securely ...

Страница 4: ...equipment grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box The splices after being made should be turned upward and pushed carefully up into the outlet box For Canadian installation and for USA fan and light kit combinations over 35 lbs in both flush and downrod mode the safety cable must be installed into the house structure beams usin...

Страница 5: ...l 25 Make wire connections to power source using wire nuts provided Make sure that no filiments are outside of the wirenut After making the wire connections the wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box The splices after being made should be turned upward ...

Страница 6: ...e plate on motor Save screw for later use 31 Place switch housing over wire harness from motor Attached switch housing on to the plate on motor aligning the keyhole slots with the preassembled screws on the plate Twist clockwise till lock Install the screw removed in step 30 Tighten all screws securely 32 Connect plug from fan to plug from switch housing Make sure the plugs are hooked together 34 ...

Страница 7: ...7 36 Install switch housing cover with the screws removed in step 34 Setting the reverse switch in the left hand side will result in downrod airflow and setting the switch in the right hand side will result in upward airflow Reverse switch ...

Страница 8: ...od of 24 hours Most noises associated with a new fan will disappear after this period 1 If this is a downrod mount fan make sure that the ridge of the canopy engages the notch in the downrod ball 2 Make sure that canopy mounting bracket or mounting plate are tightened securely to ceiling junction box and junction box is mounted firmly to ceiling joist 3 Check that all blades are screwed firmly int...

Страница 9: ...Feb 2012 New format ...

Отзывы: