Installation work and electrical wiring must be done b y qualified person(s) in accordance with  applicable codes and standards (ANSI/NFP A 70-

1999), including fire-rated construction.

Use this unit only in the manner intended b y the manufacurer.  If you have  any questions contact the manufacturer.

After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment -grounding conductor on one

side of the outlet box and ungrounded conductor on the other side of the outlet bo x.

Before you begin installing the fan, Switch power off at Service panel and lock service disconnecting means to prev ent power from being switched

on accidentally.  When the service disconnecting means cannot be lock ed, securely fasten a prominent warning device, such  as a tag, to the service

panel.

Be cautious! read all instructions and safet y information before installing your new fan. Review the accompanying assembly diagrams.

When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

Make sure the installation site you choose allows the fan blades to rotate without an y obstructions. Allow a minimum clearance of 7 feet from the

floor to the trailing edge of the blade.

WARNING – Risk of fire, electric shock, or personal injury , The fan in this box may be either directly supported from a structur al framing member of

a building and/or may be mounted to an outlet bo x marked acceptable for fan support of 31.8 kg. (70 lbs.) or less. Most outlet bo xes commonly

used for the support of luminaires ma y not be acceptable for fan support and ma y need to be replaced. Consult a qualified electrician if in doubt.

Do not bend blade holders during installation to motor, balancing or during cleaning.  Do not insert foreign object between rotating blades.

Attach the mounting bracket using only the hardware supplied with the outlet box.

To reduce the risk of fire or electric shock, do not use this fan with an y solid state fan speed control device, or v ariable speed control.

If this unit is to be installed o ver a tub or shower, it must be marked as appropriate for the application.

NEVER place a switch where it can be reached from a tub or shower .

The combustion airflow needed for safe oper ation of fuel-burning equipment may be affected by this unit’s operation. Follow the heating equipment

manufacturer’s guideline safety standards such as those published b y the National Fire Protection Association (NFPA), and the American Society for

Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.

Before servicing or cleaning unit, Switch power off at Service panel and lock service disconnecting means to prev ent power from being switched on

accidentally.  When the service disconnecting means cannot be lock ed, securely fasten a prominent warning device, such  as a tag, to the service

panel.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

Installation

WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJUR Y TO PERSONS,

OBSERVE THE FOLLOWING: READ AND SAVE THESE INSTRUCTIONS

S

AFETY

T

IPS

TTO

OO

OLLSS R

REEQ

QU

UIIR

REED

D

PPh

hiilllliip

pss S

Sccrreew

wd

drriivveerr      W

Wiirree C

Cu

utttteerrss       PPlliieerrss

S

Stteep

p LLaad

dd

deerr

Before you begin installing the fan, S witch

power off at Service panel and lock service dis -

connecting means to prevent power from being

switched on accidentally.  When the service dis -

connecting means cannot be lock ed, securely

fasten a prominent warning device, such  as a

tag, to the service panel.

Warning

-Risk of fire, electric shock, or person -

al injury. The fan in this bo x may be either

directly supported from a structural framing

member of a building and/or ma y be mounted

to an outlet box marked acceptable for fan sup -

port of of 31.8 kg (70 lbs) or less. Most outlet

boxes commonly used for the support of lummi -

naires may not be acceptable for fan support

and may need to be replaced. Consult a quali -

fied electrician if in doubt. 

2

1

OUTLET BOX METHOD

Remove Safety bar from mounting bracket by

loosing screws, sliding bar to side, and lifting it

off the 2 screws.

3

Secure mounting plate directly to a joist from

the buliding structure via the two knock out

holes on the outlet bo x. Use only the appropri -

ate wood screws and w ashers included with

your fan. Caution: Wood screws must go

through into the building joist.

5

Outlet box

Mounting
Plate

Wood

Screws

BUILDING STRUCTURE METHOD

Install the mounting Plate to appro ved fan

brace and box combination use only the hard -

ware provided with the fan brace and box.

6

FAN BRACE AND BOX METHOD

Remove the 6 screws attaching the Mounting

neck the mounting plate.  Retain the 

6

 screws

for re-assembly.

4

Содержание 5CLR66XXD-L Series

Страница 1: ...Owner s Manual Ceiling Fan Installation Instructions For 5CLR66XXD L Series Fans READ AND SAVE THESE INSTRUCTIONS Total fan weight with light 012610 ...

Страница 2: ...n of fuel burning equipment may be affected by this unit s operation Follow the heating equipment manufacturer s guideline safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities Before servicing or cleaning unit Switch power off at Service panel...

Страница 3: ...nd remove pin save pin for later 12 Install yoke cover over downrod onto fan body Install arch arms to arch hub 17 16 Install downrod into yoke Align hole in downrod with hole in y oke and install cross pin Install keeper into cross pin 14 Tighten 2 downrod set screws and lock nuts 15 Thread leadwires and safety cable through downrod 13 Tighten screw on arch hub into downrod to hold in place 18 Se...

Страница 4: ...ms using the 3 lag screws w ashers and lock washers provided Make sure that when the safety cable is fully extended the lead wires are longer than the cable and no stress is placed on the lead wires 26 Safety cable installation Safety Cable Lag Screw safety cable 3 lag screw lock washer washer Make wire connections to power source using wire nuts provided Make sure that no filiments are outside of...

Страница 5: ... screw removed in step 35 and tighten all screws securely 37 Install glass onto light kit install rubber washer on the top side of the screw nut to hold in place and tight en in direction of arrow 39 Install 3 x 60 watt candelabra bulbs Bulbs included WARNING Over lamping the fan will result in the fan lights shutting down until the proper wattage of bulbs are installed Reset the lights by turning...

Страница 6: ...Attach front cover to wall control with screws provided Snap bat tery cover in place 44 Install wall control unit to outlet bo x using machine screws provided 43 WALL MOUNT INSTALL ...

Страница 7: ...light dimmer The light will cycle from bright to dim to bright until button is released Light will maintain last setting if turned off FORWARD REVERSE Depress rev button allow a few seconds for remote to change rotation direction with fan running HIGH SPEED MEDIUM SPEED LOW SPEED FAN OFF SETTING Turns fan off only FAN REVERSE Press once to change direction of the fan Fanmust be running to reverse ...

Страница 8: ...een the blade and blade holder at the screw closest to the motor To adjust a blade tip up insert washer not supplied between the blade and blade holder at the two screws farthest from the motor Reverse the position of the w asher if blades mount from top of blade 6 If blade wobble is still noticeable interchanging two adjacent side b y side blades can redistribute the weight and possibly result in...

Страница 9: ...Instructions pour l installation d un ventilateur de plafond manuel de l utilisateur Poids total du ventilateur et du kit d éclairageht Por 5CLR66XXD L Serie Ventilateurs LIRE ET GARDER CES INSTRUCTIONS ...

Страница 10: ... tion 13 Ne JAMAIS installer de commutateur en un endroit accessible d une baignoire ou douche 14 Le débit en air de combustion requis pour le fonctionnement en toute sécurité d équipements alimentés par du combustible peut être affecté par la mise en marche de cette unité Suivre les directiv es et appliquer les normes de sécurité indiquées par le fabricant d un tel équipement comme celles commu n...

Страница 11: ...er la goupille Enlever la sphére 12 Placer le couvercle décoratif supérieur par dessus la tige descen dante sur le corps du v entilateur Remettre la chape en place en pous sant Installer les bras de la voûte sur le moyeu de la voûte 17 16 Faire passer le fil au tr avers de la tige descendante Installer la tige descendante avec les couvercles de monture et de chape dans la chape Aligner le trou de ...

Страница 12: ...est situé en haut du v entilateur Pour le montage destiné au Canada que ce soit selon la méthode de suspension encastrée ou selon la méthode de la tige verticale le câble de sécurité doit être installé dans les poutres de la charpente du bâtiment à l aide des vis à bois à tête carrée de 7 62 cm fournies à cet effet Assurez vous que lorsque le câble de sécurité est entière ment déplié les fils de c...

Страница 13: ... 37 Installez le verre sur le kit léger installez la rondelle en caoutchouc du côté supérieur de l écrou de vis sur la prise en place et serrez dans la direction de la flèche 39 Installer 3 ampoules de 60 w atts équipées d un culot de type candélabre Incluses AVERTISSEMENT les lumières du ventila teur ne s allumeront pas avec des ampoules au wattage supérieur à celui nécessaire Deconnecter les lum...

Страница 14: ...eur avant à l interrupteur de commande murale à l aide des vis fournis à cet effet 44 Reliez l interrupteur de commande murale à la boîte de sortie de courant à l aide des vis mécaniques fournis à cet effet 43 LE BÂTI DE MUR INSTALLENT ...

Страница 15: ... un cycle de lumineux pour obscurcir à lumineux jusqu à ce que le bouton soit libéré La lumière maintiendra pour la dernière fois le réglage si arrêtée FORWARD REVERSE enfoncent le bouton de tour accordent quelques sec ondes pour que l extérieur change la direction de rotation avec le fonction nement de ventilateur À GRANDE VITESSE VITESSE MOYENNE À VITESSE RÉDUITE ÉVENTEZ OUTRE DU RÉGLAGE ventila...

Страница 16: ...ure por chaque pale Si certaines pales ne sont pas de niv eau celui ci peut être obtenu en appliquant la procédure suiv ante Pour abaisser l extrémité d une pale introduire une rondelle non fournie entre la pale en question et son porte pale sous la vis qui est la plus proche du bloc moteur Pour remonter l extrémité d une pale introduire une rondelle non fournie entre la pale en question et son po...

Страница 17: ...6 21 06 REV 0 New made from 5GMR manual Aug 13 09 6 set screws instead of 4 Jan 25 10 Key holes ...

Отзывы: