Monte Carlo Fan Company 3BvR52XXd-L Series Скачать руководство пользователя страница 2

Installation work and electrical wiring must be done by qualified person(s) in accordance with applicable codes and standards (ANSI/NFPA 70-

1999), including fire-rated construction.

Use this unit only in the manner intended by the manufacturer.  If you have  any questions contact the manufacturer.

After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conductor on

one side of the outlet box and ungrounded conductor on the other side of the outlet box.

Before you begin installing the fan, Switch power off at Service panel and lock service disconnecting means to prevent power from being

switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag,

to the service panel.

Be cautious! read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.

When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7 feet from

the floor to the trailing edge of the blade.

To reduce the risk of fire, electric shock, or personal injury, mount to outlet box or supporting system acceptable for fan support. 

(Mounting must support at least 35 lbs.)

Do not bend blade holders during installation to motor, balancing or during cleaning.  Do not insert foreign object between rotating blades.

Attach the mounting bracket using only the hardware supplied with the outlet box.

To reduce the risk of fire or electric shock, do not use this fan with any solid state fan speed control device, or variable speed control.

If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application.

NEVER place a switch where it can be reached from a tub or shower.

The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heating equip-

ment manufacturer’s guideline safety standards such as those published by the National Fire Protection Association (NFPA), and the American

Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.

Before servicing or cleaning unit, Switch power off at Service panel and lock service disconnecting means to prevent power from being switched

on accidentally.  When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the

service panel.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

Installation

WaRnInG

: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS,

OBSERVE THE FOLLOWING: READ AND SAVE THESE INSTRUCTIONS

S

aFeTy

T

IpS

TooLS ReQuIRed

Phillips Screwdriver      Wire Cutters       Pliers      Step Ladder

Before you begin installing the fan, Switch power off

at Service panel and lock service disconnecting means

to prevent power from being switched on accidentally.

When the service disconnecting means cannot be

locked, securely fasten a prominent warning device,

such  as a tag, to the service panel.

1

Before installing this fan make sure the outlet

box is properly installed to the house structure.

To reduce the risk of fire, electric shock, or per-

sonal injury, mount to outlet box or supporting

system acceptable for fan support. 

(Mounting must support at least 35 lbs.)

2

3

For Flush mount with

or without light kit go

to step 4.

For downrod mount

with or without light

kit go to step 32.

Remove the coupler from the 

mounting plate by unscrewing 6

screws. Save the yoke and screws

for future use when installing 

downrod.

4

Thread safety cable through center

hole of the mounting plate. Thread

your house wires through center hole

also.These will be needed for wiring

of the fan.

5

For Canadian installation and for USA fan and

light kit combinations over 35 lbs, in both flush

and downrod mode the safety cable must be

installed into the house structure beams using

the 3” lag screws provided.  Make sure that

when the safety cable is fully extended the

leadwires are longer than the cable and no

stress is placed on the leadwires.

6

Safety cable installation

Safety cable

Lag Screw

Lag Screw

Safety cable

Washer

Lock Washer

Содержание 3BvR52XXd-L Series

Страница 1: ...ing Fan Installation Instructions For 3BvR52XXd L Series Fan Read and Save TheSe InSTRucTIonS Total fan weight with lights Flush Mount No light kit Downrod with light kit Flush Mount Light kit Downrod...

Страница 2: ...s operation Follow the heating equip ment manufacturer s guideline safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrig...

Страница 3: ...ots in the motor bracket Securely tighten the locknuts onto the threaded studs 11 Make wire connections to power source using wire nuts provided Make sure that no filiments are outside of the wirenut...

Страница 4: ...plug from fan to plug from switch cap 21 Remove the double sided sticky tape and stick the capacitor to the switch cap plate Receiver needs to be stuck to the switch cap plate also by using 2 double s...

Страница 5: ...structural ceiling member a loose box will cause the fan to wabble use only the screws provided with the outlet box 32 Thread leadwires and safety cable through the mounting plate Loosen the 2 set scr...

Страница 6: ...through the hanger ball and place onto the downrod 49 Position the pin through the two holes in the downrod and align the hanger ball so the pin is captured in the groove in the top of the hanger bal...

Страница 7: ...n to the White or Neutral wire from the power source Connect the black wire from the fan to the Black or hot wire from the power source Connect all Green Yellow wires from the fan Downrod and mounting...

Страница 8: ...mmer once quickly To turn off press once quickly while light is on To dim light hold down button light dimmer The light will cycle from bright to dim to bright until button is released Light will main...

Страница 9: ...ween the blade and blade holder at the screw closest to the motor To adjust a blade tip up insert washer not supplied between the blade and blade holder at the two screws farthest from the motor Rever...

Страница 10: ...pour l installation d un ventilateur de plafond Poids total du ventilateur LIRE ET GARDER CES INSTRUCTIONS Por 3BVR52XXD L Ventilateurs Tige avec le kit l ger Tige sans kit l ger B ti affleurant kit l...

Страница 11: ...tilateur Le montage doit supporter au moins 35 lbs 16 kg 9 Ne pas plier les porte pales au cours de l installation sur le moteur de l quilibrage ou du nettoyage Ne pas ins rer de corps tranger entre l...

Страница 12: ...e de moteur Serrez solidement les contre crous sur les goujons filet s 11 Serrez la vis en bois fixant le c ble de s ret 7 10 tablissez les rapports de fil la source d n ergie utilisant des crous de f...

Страница 13: ...peau de finial de l assembleur 23 Pour le ventila teur avec le kit l ger vont tape 21 25 Pour le ventila teur en dehors l e kit l ger vont tape26 31 Enlevez le double a d grossi bande collante et coll...

Страница 14: ...parfaitement attach e au moins en deux points une pi ce de charpente du pla fond une bo te de sortie de courant mal attach e provoquera des secousses du ventilateur Utilisez uniquement les vis fourni...

Страница 15: ...Remarque l Epingle doit tre install e avec la tige et la fixation 50 Remonter la fixation fermement con tre l pingle et bien serrer les vis dans la fixation Une vis desserr e pourrait amener le venti...

Страница 16: ...la bo te de sortie et le conducteur sans mise la terre de l autre c t de la bo te de sortie Des fils piss s devraient tre tourn s vers le haut et pouss s soigneusement vers le haut dans la bo te de so...

Страница 17: ...serrez une fois rapidement tandis que la lumi re est allum e Pour obscurcir la lumi re maintenez le bouton grada teur l ger La lumi re fera un cycle de lumineux pour obscurcir lumineux jusqu ce que l...

Страница 18: ...taines pales ne sont pas de niveau celui ci peut tre obtenu en appliquant la proc dure suivante Pour abaisser l extr mit d une pale introduire une rondelle non fournie entre la pale en question et son...

Отзывы: