– 27 –
5. Carefully pull, then lower the broiler element
towards the front of the oven until the element
terminals are accessible.
IMPORTANT:
The lower wattage outer element
utilizes
3
/
16
16
-in. terminal connections. The higher
wattage inner element utilizes ¼-in. terminal
connections.
6. Disconnect the wires from the broiler element.
Broil Element
4. Remove the four ¼-in. hex-head screws that
hold the broiler element to the oven cavity.
Vent Tube/Smoke Eliminator
The oven vent tube/smoke eliminator is located in
the top left front corner of the oven cavity above
the broiler element shield. Air vented from the oven
cavity will pass through the catalyst, then enter the
vent tube of the power vent assembly.
To remove the vent tube/smoke eliminator:
Place an oven rack in the top position and
remove any remaining oven racks. (See
Oven
Racks
.)
Remove the 2 hex-head screws that attach the
front of the broiler element to the oven cavity,
then carefully lower the broiler element to the
oven rack.
1.
2.
3. Remove the 2 hex-head screws that hold the
vent tube to the top of the oven cavity. Do not
remove the remaining hex-head screws, they
are for the power vent assembly.
Broil Element
4. Remove the vent tube from the oven cavity.
Vent Tube