SR5i Technical Manual
TSP095.doc Issue 1.0 – July 2004
©
Money Controls 2004. All rights reserved.
23.3 Cleaning
The coin rundown area should be cleaned regularly to ensure accurate discrimination of
coins and tokens. Only a damp cloth should be used.
Under NO circumstances should any solvent, abrasive or foam type cleaner be used.
Access to the coin rundown is gained by opening the reject gate.
23.4 Accept Gate
Please refer to
Figure 29
.
To detach the accept gate, first undo screw (9) and remove the rundown cover. Carefully
slide the gate spring (12) towards the rear of the SR5i and remove. Pull the gate forward
and downward to remove.
Re-fitting is the reverse of removal.
Take extreme care when re-fitting the accept gate spring.
23.5 Sorter
Please refer to
Figure 29
.
Removal and Re-fitting.
Undo screw (9) and remove the rundown cover. The sorter can be unplugged and
withdrawn.
When re-assembling, ensure the sorter flaps are correctly fitted and not trapped.
23.6 Rear Cover
No User serviceable parts.
Access to all switches is achievable without removing the cover. Therefore the cover should
only be removed by approved service centres.