32D1999
5
PRODUCT SPECIFICATIONS
NATURAL GAS
Manual Pressure
Milli-Volt Pressure
Regulator Pressure Setting: 4" w.c.
Regulator Pressure Setting: 4.0" w.c.
Gas Inlet Pressure:
Max. 10 1/2" w.c.
Gas Inlet Pressure:
Max. 10 1/2" w. c. • Min. 6" w.c.
Min. 6" w.c.
PROPANE/LPG
Note: An external regulator is required to reduce supply pressure to a maximum of 13" w.c.
Manual Pressure
Milli-Volt Pressure
Regulator Pressure Setting:
10" w.c.
Regulator Pressure Setting:
10" w.c.
Gas Inlet Pressure:
Maximum 13" w.c.
Gas Inlet Pressure:
Maximum 13" w.c.
Minimum 11" w.c.
Minimum 11" w.c.
IGNITION CONTROLS
Piezo ignitor allows ignition of the pilot without the use of matches or batteries.
Manual control with pilot has three (3) positions:
OFF
- All gas to the gas logs is shut off at the valve.
IGN
- Valve position to light/maintain a standing pilot.
ON
- Valve position to light/maintain the gas burner.
Manual control without pilot has two (2) positions:
OFF
- All gas to the gas logs is shut off at the valve.
ON
- Valve position to light/maintain the gas burner.
Milli-Volt control with pilot has three (3) positions:
OFF
- All gas to the gas logs is shut off at the valve.
IGN
- Valve position to light/maintain a standing pilot.
ON
- Valve position to light/maintain the gas burner.
Model Number
Pilot
Control Type
Gas Rate Min BTU/Hr
VDY24/18NMP
Yes
Manual
(Thermocouple)
50,000
VDY24/18NM
No
Manual
50,000
VDY24/18VP
Yes
Milli-Volt
(Thermopile)
50,000
VDY30NMP
Yes
Manual
(Thermocouple)
65,000
VDY30NM
No
Manual
65,000
VDY30NVP
Yes
Milli-Volt
(Thermopile)
65,000
Model Number
Pilot
Control Type
Gas Rate Min BTU/Hr
VDY24/18PMP
Yes
Manual
(Thermocouple)
50,000
VDY24/18PVP
Yes
Milli-Volt
(Thermopile)
50,000
VDY30PMP
Yes
Manual
(Thermocouple)
65,000
VDY30PVP
Yes
Milli-Volt
(Thermopile)
65,000