background image

S

ELECTING

  A L

OCATION

6

A floor stand model XFS is available from your dealer.  The floor stand
enables these heaters to be installed freestanding as shown by Figure
2.

The minimum clearances (see Figure 1) between combustible material
and a freestanding heater installed on a floor stand are:

Back  - 0 inches (floor stand may touch rear wall)

Floor - 0 inches (floor stand may rest directly on floor - See "

F

LOOR

P

ROTECTION

" information below.)

Sides - 12 inches on one side of the heater;

18 inches on the opposite side of the heater.

Top -

36 inches

Front - 48 inches

When selecting a location for the heater, be sure attention is given to
the following considerations.

1. Some materials such as vinyls and plastics will deform at relatively

low temperatures and must be kept at greater clearance distances
than the minimum clearances specified above.

2. The heater should be located centrally within the area where heat

is desired, but out of traffic areas, or areas where children play, to
minimize the chance of persons accidentally contacting the hot
surface of the heater.

3. The heater must not be located near doorways or in other areas

where drafts may affect the operation of the pilot or burner assembly.

4.

D

O

 

NOT

 

INSTALL

 

THE

 

HEATER

 

BENEATH

 

CURTAINS

 

OR

 

DRAPES

.

To  comply with the Z21.11.2 standard of the American National

Standards Institute, none of the heaters described by this manual
may be installed in a bathroom and the IRVF2T is the only model
that may be installed in a bedroom.  If an infrared heater is installed
in a bedroom, it must be wall mounted.  Floor stand mounted heaters
are prohibited in bedrooms.

F

LOOR

 P

ROTECTION

Some Flooring materials will discolor or otherwise deteriorate due to
the temperature underneath the heater.  Therefore, when the heater is
installed freestanding with a floor stand in place on carpet, tile, linoleum
or any combustible material other than wood flooring, the heater must
be installed with a wood panel, metal panel or stoveboard extending at
least the full width and depth of the floor stand.  See Figure 2.

Danger:  Operation of the heater
as a freestanding heater without
the proper floor stand correctly
installed may lead to fire or the
production of carbon monoxide
gas.

Warning: If heater is installed and
operated at clearances less than
those specified as minimum in
these instructions, a fire hazard
may exist with possible fire
causing property damage or
personal injury.  If the heater is
operated at clearances less than
those specified in these
instructions, insufficient air may
be supplied to the heater causing
poisonous carbon monoxide to
be produced.

Notice: The Z21.11.2 standard of
the American National Standards
Institute prohibits the installation
of a heater with a rating greater
than 6,000 Btu’s per hour in a
bathroom.  The standard also
prohibits the installation of a
heater with a rating greater that
10,000 Btu’s per hour in a
bedroom.

Warning:  Failure to adequately
protect the flooring materials
under a floor mounted heater can
lead to damaged flooring material
or fire.

53D9012. Rev 1 03/03

Содержание IRVF2T

Страница 1: ...LY CALL YOUR GAS SUPPLIER FROM A NEIGHBOR S PHONE FOLLOW THE GAS SUPPLIER S INSTRUCTIONS IF YOU CANNOT REACH YOUR GAS SUPPLIER CALL THE FIRE DEPARTMENT WARNING IF THE INFORMATION IN THIS MANUAL IS NOT...

Страница 2: ...ILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM WITH THE HEATER DO NOT PLACE CLOTHING OR OTHER FLAMMABLE MATERIAL ON OR NEAR THE HEATER ANY SAFETY SCREEN OR GUARD REMOVED FOR SERV...

Страница 3: ...s are detected report this to the dealer from whom you purchased the heater and get the deficiency corrected before installing and using the heater Do not install or use a damaged or incomplete heater...

Страница 4: ...5 PARTS DIAGRAM 2 8 11 IN WC 555 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 FRONT FRONT RIGHT RIGHT SIDE SIDE LEFT LEFT SIDE SIDE TOP TOP 53D9012 Rev 1 03 03...

Страница 5: ...Hearth Plate Assembly Reflector Left Side Pntd Brace Reflector Piezo Cable Cabinet Side Left W Labels Piezo Ignitor Cabinet Top w Caution Label Pilot NAT Gas Pilot LP Gas Venturi Shield Burner Tube A...

Страница 6: ...ions of this manual The control system on this heater serves several functions It regulates the incoming gas to the correct pressure for the combustion rate required It will not regulate LP gas direct...

Страница 7: ...inches Sides 12 inches on one side of the heater 18 inches on the opposite side of the heater Top 36 inches Front 48 inches 36 MIN 36 MIN SEE NOTE 2 SEE NOTE 2 18 MIN 18 MIN SEE NOTES SEE NOTES 1 2 1...

Страница 8: ...the only model that may be installed in a bedroom If an infrared heater is installed in a bedroom it must be wall mounted Floor stand mounted heaters are prohibited in bedrooms FLOOR PROTECTION Some F...

Страница 9: ...aded joints of gas piping must be resistant to the action of liquefied petroleum gas Gas piping must be of sufficient size to provide a minimum natural gas pressure at the appliance of 7 inches water...

Страница 10: ...AS SUPPLY IN BOTTOM OF HEATER SUPPLY IN BOTTOM OF HEATER FIGURE 3 UNION SHUTOFF VALVE JOIST SEDIMENT TRAP TEE GAS SUPPLY LINE FLOOR NOTE A PLUGGED 1 8 NPT TAP MUST BE LOCATED SOMEWHERE BETWEEN THE SHU...

Страница 11: ...put rating of all gas fired appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1 000 Btu per hour 4 8m per kW of the aggregate input...

Страница 12: ...ve off carbon monoxide an odorless poisonous gas If this heater shuts off during operation do not relight it until you provide additional fresh air If permanent provisions for providing additional fre...

Страница 13: ...e not designed for use with optional blowers These blowers are the only blowers acceptable for use on these heaters The use of any other blower could adversely and dangerously affect the operation of...

Страница 14: ...into the wall as shown by Figure 5 USE HAMMER TO DRIVE ANCHOR INTO WALL USE HAMMER TO DRIVE ANCHOR INTO WALL NOTE ANCHORS ARE FOR USE IN HOLLOW NOTE ANCHORS ARE FOR USE IN HOLLOW WALLS WALL AREA BETW...

Страница 15: ...of the heater Insert two screws from the bag of fasteners through the holes in the standoffs Tighten the screws into the wall until the heater is firmly secured to the wall See Figure 6 Proceed to St...

Страница 16: ...n wall do the following Turn the gas off at the shutoff valve Loosen the four screws which secure the control s mounting bracket Item No 23 of PARTS DIAGRAM found in the upper righthand corner of the...

Страница 17: ...CE 21 After all checks are satisfactorily completed as described above turn the heater s control knob to Pilot and reinstall the heater s front panel See Figure 6 22 The heater may now be operated for...

Страница 18: ...ntrol knob cl ll not stay lit after several tries turn the gas control knob clockwise to OFF and call your service lier gas supplier ng steadily slowly turn the control knob coun and burning steadily...

Страница 19: ...minute a 3 After the pilot is lit continue to hold the control knob down for a minute and then release it The control knob nd then release it The control knob should pop back up fully and the pilot sh...

Страница 20: ...stible materials gasoline and other flammable liquids 9 Do take the necessary precautions during any pressure testing of the heater s gas supply piping system 10 Do keep children and mentally impaired...

Страница 21: ...CE The pilot gas flow is not adjustable on this heater Proper operation of the ODS Oxygen Depletion Sensitive Pilot Safety System is dependent upon the pilot gas flow rate and any attempt to adjust th...

Страница 22: ...their probable cause and solution Any adjustments and or replacements must be performed by a qualified person Do not replace any component with a different type Only use components supplied by the man...

Страница 23: ...nsequential damages so the above limitation or exclusion may not apply to you 4 This warranty applies only to the original purchaser and may not be transferred 5 This warranty applies only to a gas he...

Страница 24: ...ATTENTION APPLIANCE INSTALLER PLEASE RETURN THESE OPERATING AND INSTALLATION INSTRUCTIONS TO THE APPLIANCE FOR CONSUMER USE 53D9012 REV 1 03 03...

Отзывы: