background image

 072348

 072344

 069103

 075280

 050980

 078073

 051041

 071705

 072087

 072088

 072425

 072090

 055875

 054461

 072423

 052997

 074041

 069104

 

 067972

 078074

 071040

 074036

26D2529

14D0476

 055874

 072424

072084 (5)

072085 (5)

 072287

   P549

 050889

 078040

 072341

 072337

 069103

 075279

 055870

 078073

 051041

 071705

 072087

 072088

 072425

 072090

 055873

 054461

 072421

 052997

 074040

 069104

 067972

 078074

 071040

 074035

26D2529

14D0476

 055872

 072422

072084 (3)

072085 (3)

 072286

   P549

 050889

 077520

 30

 29

 28

 27

 26

 25

 24

 23

 22

 21

 20

 19

 18

 17

 16

 15

 14

 13

 12

 11

 10

  9

  8

  7

  6

  5

  4

  3

  2

  1

Dress Guard

Cabinet, Front Pntd.

Reflector, Right Side Pntd.

Deflector Pntd.

Heat Shield Weld Assembly

Cabinet Side Right W/Markings

Control Ring 

Regulator Bracket

Regulator (NAT Gas)

Regulator (LP Gas)

Regulator To Control Tube Assembly

Thermostat Control

Burner Shield

Control Bracket Assembly Pntd.

Pilot Tube Assembly

Wall Anchor

Front Shield & Hearth Plate Assembly

Reflector, Left Side Pntd.

Brace Reflector

Piezo Cable

Cabinet Side Left W/Labels

Piezo Ignitor

Cabinet Top w/Caution Label

Pilot (NAT Gas)

Pilot (LP Gas)

Venturi Shield

Burner Tube Assembly

Orifice (Nat Gas)

Orifice (LP Gas)

Burner Assembly

Clamp, Thermostat Bulb

Speed Nut 10-24 U Type

Cabinet Back Pntd.

   

      1

      1

      1

      1

      1

      1

      1

      1

      1

      1

      1

      1

      1

      1

      2

      1

      1

      1

      1

      1

      1

      1

      1

      1

      1

      1

      see ( )
      see ( )

      1

      2

      4

      1

 072334

 072330

 069103

 075278

 078073

 051041

 071705

 072086

 072088

 072425

 072090

 055878

 054461

 072419

 052997

 074039

 069104

 049863

 067972

 078074

 071040

 074034

26D2529

14D0476

 058711

 072420

072084 (2)

072085 (2)

 072285

   P549

 050889

 077519

PART NO.

    IRVF5T

PART NO.

    IRVF3T

NO.

KEY

DESCRIPTION

 HEATER

QTY. PER 

PART NO.

    IRVF2T

      1

6

All repair part orders should be placed through your local dealer.  To ensure prompt and accurate service, please
provide the following information when placing a repair part order:  Model number of your Appliance, Part Name,
Part Number, and Quantity of parts needed.  D

O

 

NOT

 

TAKE

 

A

 

HEATER

 

NEEDING

 

REPAIR

OR

 

BELIEVED

 

TO

 

BE

 

DEFECTIVE

BACK

 

TO

THE

 

SELLER

.

P

ARTS

  L

IST

3

53D9012. Rev 1 03/03

Содержание IRVF2T

Страница 1: ...LY CALL YOUR GAS SUPPLIER FROM A NEIGHBOR S PHONE FOLLOW THE GAS SUPPLIER S INSTRUCTIONS IF YOU CANNOT REACH YOUR GAS SUPPLIER CALL THE FIRE DEPARTMENT WARNING IF THE INFORMATION IN THIS MANUAL IS NOT...

Страница 2: ...ILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM WITH THE HEATER DO NOT PLACE CLOTHING OR OTHER FLAMMABLE MATERIAL ON OR NEAR THE HEATER ANY SAFETY SCREEN OR GUARD REMOVED FOR SERV...

Страница 3: ...s are detected report this to the dealer from whom you purchased the heater and get the deficiency corrected before installing and using the heater Do not install or use a damaged or incomplete heater...

Страница 4: ...5 PARTS DIAGRAM 2 8 11 IN WC 555 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 FRONT FRONT RIGHT RIGHT SIDE SIDE LEFT LEFT SIDE SIDE TOP TOP 53D9012 Rev 1 03 03...

Страница 5: ...Hearth Plate Assembly Reflector Left Side Pntd Brace Reflector Piezo Cable Cabinet Side Left W Labels Piezo Ignitor Cabinet Top w Caution Label Pilot NAT Gas Pilot LP Gas Venturi Shield Burner Tube A...

Страница 6: ...ions of this manual The control system on this heater serves several functions It regulates the incoming gas to the correct pressure for the combustion rate required It will not regulate LP gas direct...

Страница 7: ...inches Sides 12 inches on one side of the heater 18 inches on the opposite side of the heater Top 36 inches Front 48 inches 36 MIN 36 MIN SEE NOTE 2 SEE NOTE 2 18 MIN 18 MIN SEE NOTES SEE NOTES 1 2 1...

Страница 8: ...the only model that may be installed in a bedroom If an infrared heater is installed in a bedroom it must be wall mounted Floor stand mounted heaters are prohibited in bedrooms FLOOR PROTECTION Some F...

Страница 9: ...aded joints of gas piping must be resistant to the action of liquefied petroleum gas Gas piping must be of sufficient size to provide a minimum natural gas pressure at the appliance of 7 inches water...

Страница 10: ...AS SUPPLY IN BOTTOM OF HEATER SUPPLY IN BOTTOM OF HEATER FIGURE 3 UNION SHUTOFF VALVE JOIST SEDIMENT TRAP TEE GAS SUPPLY LINE FLOOR NOTE A PLUGGED 1 8 NPT TAP MUST BE LOCATED SOMEWHERE BETWEEN THE SHU...

Страница 11: ...put rating of all gas fired appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1 000 Btu per hour 4 8m per kW of the aggregate input...

Страница 12: ...ve off carbon monoxide an odorless poisonous gas If this heater shuts off during operation do not relight it until you provide additional fresh air If permanent provisions for providing additional fre...

Страница 13: ...e not designed for use with optional blowers These blowers are the only blowers acceptable for use on these heaters The use of any other blower could adversely and dangerously affect the operation of...

Страница 14: ...into the wall as shown by Figure 5 USE HAMMER TO DRIVE ANCHOR INTO WALL USE HAMMER TO DRIVE ANCHOR INTO WALL NOTE ANCHORS ARE FOR USE IN HOLLOW NOTE ANCHORS ARE FOR USE IN HOLLOW WALLS WALL AREA BETW...

Страница 15: ...of the heater Insert two screws from the bag of fasteners through the holes in the standoffs Tighten the screws into the wall until the heater is firmly secured to the wall See Figure 6 Proceed to St...

Страница 16: ...n wall do the following Turn the gas off at the shutoff valve Loosen the four screws which secure the control s mounting bracket Item No 23 of PARTS DIAGRAM found in the upper righthand corner of the...

Страница 17: ...CE 21 After all checks are satisfactorily completed as described above turn the heater s control knob to Pilot and reinstall the heater s front panel See Figure 6 22 The heater may now be operated for...

Страница 18: ...ntrol knob cl ll not stay lit after several tries turn the gas control knob clockwise to OFF and call your service lier gas supplier ng steadily slowly turn the control knob coun and burning steadily...

Страница 19: ...minute a 3 After the pilot is lit continue to hold the control knob down for a minute and then release it The control knob nd then release it The control knob should pop back up fully and the pilot sh...

Страница 20: ...stible materials gasoline and other flammable liquids 9 Do take the necessary precautions during any pressure testing of the heater s gas supply piping system 10 Do keep children and mentally impaired...

Страница 21: ...CE The pilot gas flow is not adjustable on this heater Proper operation of the ODS Oxygen Depletion Sensitive Pilot Safety System is dependent upon the pilot gas flow rate and any attempt to adjust th...

Страница 22: ...their probable cause and solution Any adjustments and or replacements must be performed by a qualified person Do not replace any component with a different type Only use components supplied by the man...

Страница 23: ...nsequential damages so the above limitation or exclusion may not apply to you 4 This warranty applies only to the original purchaser and may not be transferred 5 This warranty applies only to a gas he...

Страница 24: ...ATTENTION APPLIANCE INSTALLER PLEASE RETURN THESE OPERATING AND INSTALLATION INSTRUCTIONS TO THE APPLIANCE FOR CONSUMER USE 53D9012 REV 1 03 03...

Отзывы: