OPERATING INSTRUCTIONS

1.      STOP! Read the safety information .
2.      Make sure the manual shutoff valve is fully open.
3.      This heater is equipped with an ignition device (piezo) which automatically lights the pilot.
4.      

See Figure 28, page 26 

for the location of the piezo ignitor and control knob. Turn control knob clockwise

 to the OFF position.

5.      Wait 5 minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! 

Follow safety instructions under 

What to Do if you Smell Gas, page 26. 

If you do not smell gas, go to the 

next step.

6.      Turn the gas control knob counterclockwise

 to the IGN position. See 

Figure 32.

 Push in and 

hold control knob for 5 seconds.

7.      With the control knob pushed in and held, push and release the piezo ignitor button to light the ODS 

pilot. The pilot is located on the right side of the heater, behind the front log and in front of the main 
burner. If piezo ignitor does not light the pilot, 

see Match Lighting Instructions, page 30.

8.      Hold the control knob in for an additional 10 seconds to prevent the ODS pilot from shutting off the gas 

while the thermocouple is warming up.

9.      Release the control knob. 
         •     If the knob does not pop out when released, stop and immediately call your service technician or gas 

supplier.

         •     If the ODS pilot will not stay lit after several tries, push and turn the control knob clockwise

 to OFF. Release and wait 15 seconds. Repeat steps 6 through 9.

10.    Turn control knob to any position between LOW and HIGH. The knob position controls the thermostat 

temperature. 

See

 

Figure 32

.

11.    The heater is now in proper operation. The following procedure should be used to achieve thermostatic 

control of the desired room temperature.

a.   Operate unit at higher setting until desired room temperature 

is achieved.

b.   At the desired temperature, slowly turn the knob clockwise 

and stop rotating  when flame disappears.

c.   Thermostat is now set to maintain the current room tempera-

ture.

d.   As the room temperature decreases, the thermostat valve will 

open to ignite the front and rear  burner.

e.   When the temperature reaches its set point (knob position), 

the thermostat valve will again shut off the front and rear burner.

f.    This is the normal cycle of the heater.

Figure 32 - Rotation of Control Knob

Rotate

 

TO TURN OFF GAS TO HEATER

 

   1.   Turn control knob clockwise 

 to 

OFF 

position to completely shut off the heater.

   2.    If applicable: Turn off all electric power to the heater.

 THERMOSTAT CONTROL LIGHTING INSTRUCTIONS 

Содержание DLX18

Страница 1: ...any electrical switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the f...

Страница 2: ...replace Preparation 17 Installing Vented Applications 18 Connecting the Gas 19 Checking Gas Pressure 20 Electrical Wiring Milli volt 21 Log Placement 23 Flame Appearance 24 Checking the Burner Flame 2...

Страница 3: ...rence IMPORTANT Read these instructions carefully before installing or trying to operate this vent free gas heater IMPORTANT SAFETY INFORMATION 1 Due to high temperatures the heater should be located...

Страница 4: ...test pressures in excess of 1 2 psig 3 5 kPa 21 The appliance must be isolated from the gas supply piping system by closing its equipment shutoff valve during any pressure testing of the gas supply pi...

Страница 5: ...r shipping damage If any parts are missing or damaged immediately inform the dealer from whom you purchased the appliance Do not attempt to install any part of the appliance unless you have all parts...

Страница 6: ...tor allows ignition of the pilot without the use of matches or batteries Manual control has four 4 positions OFF All gas to the gas logs is shut off at the valve IGN Valve position to light maintain a...

Страница 7: ...ot be installed in a confined space or unusually tight construction unless provisions are provided for ade quate combustion and ventilation air The National Fuel Gas Code ANSI Z223 1 NFPA54 defines a...

Страница 8: ...tion would be based only on the room with the heater BTU HR 151 2 x 12 x 8 x 1000 50 GENERAL INSTALLATION INFORMATION Figure 1 Example of a Large Room with 1 2 Wall Divider Counter Fireplace x 1000 x...

Страница 9: ...I Z21 91 typically referred to as a Universal Firebox as long as firebox hearth dimen sions meet the minimum hearth dimensions shown below Figure 2 Minimum Hearth Dimensions This appliance is for inst...

Страница 10: ...the base or bottom surface of the unit See Table The log set should be placed against or as near as possible to the rear wall of the fireplace firebox Depth of fireplace firebox SeeTable Figure 3 Refe...

Страница 11: ...in Figures 4 through 12 and defined in the fireplace manufacturer s instructions are minimum clearances to maintain when installing this heater Left and right clearances are determined when facing the...

Страница 12: ...ese minimum clearances you must operate the heater with chimney flue damper open See Installing Vented Applications found on page 17 Figure 5 Measuring Heat Resistant Material HEAT RESISTANT REQUIREME...

Страница 13: ...igure 9 page 15 Less than 8 Extend heat resistant material to at least Extend heat resistant material to at least 8 install hood and observe profiles shown 8 install hood and observe profiles shown in...

Страница 14: ...opening CLEARANCES AND HEIGHT REQUIRMENTS Figure 7 Minimum Mantel Clearance with No Hood DLX18 Figure 8 Minimum Mantel Clearance with Hood All Models Example The bottom of the mantel may project from...

Страница 15: ...ning exceeding the maximum acceptable distance of 6 If your mantel profile is unsafe you may either Raise the mantel to an acceptable height OR Remove the mantel CLEARANCES AND HEIGHT REQUIREMENTS Fig...

Страница 16: ...Figure 11 OR The gas log heater may be installed nearer to the floor if a minimum of 14 of noncombustible material such as slate or marble is installed between the base of the fireplace and the combus...

Страница 17: ...e this cleaning performed annually after installation Seal any fresh air vents or ash clean out doors located on floor or wall of fireplace If not drafting may cause pilot outage or sooting Use a heat...

Страница 18: ...s logs function as a system If the fireplace is spilling into the room check with a match or a smoke stick reposition the damper clamp until a positive draft is obtained by opening the damper If negat...

Страница 19: ...that the Pressure Tapping Point May Be Installed Use new black iron or steel pipe Internally tinned copper or copper tubing can be used per National Fuel Code section 2 6 3 providing gas meets hydrog...

Страница 20: ...point Use test point closest to control knob After tak ing pressure reading be sure and turn captured screw clockwise firmly to reseal Do not over torque Check for gas leaks MILLIVOLT CONTROL Figure...

Страница 21: ...trol THAT DOES NOT USE 110 VAC TO OPERATE CONNECTING OPTIONAL WALL SWITCH OR THERMOSTAT 1 Use 18 awg two wire cable 15 feet maximum length 2 At one end of the cable connect both wires to the wall swit...

Страница 22: ...S READING TERMINALS SHOULD BE A COMPLETE 2 3 CLOSED CLOSED SYSTEM B THERMOPILE 1 2 OPEN OPEN OUTPUT CONNECTING REMOTE RECEIVER 1 Plug in the remote connector to the remote receiver wire 2 Connect the...

Страница 23: ...stall the Cross Log 5 by engaging the holes in the cross log onto pins on the rear log PLACING THE DECORATIVE ROCK Figure 21 Proper Sequence of Log Installation Rear Log 1 The positioning of the logs...

Страница 24: ...main burner cannot function reliably See Figure 23 and 25 for incorrect shape of pilot flame MILLI VOLT CONTROL NOTE For illustration purposes natural gas and propane components are combined Figure 2...

Страница 25: ...ctly into the fireplace Do not place a blower inside the burn area of the firebox Ceiling fans may create drafts that alter flame patterns Sooting and improper burning will result During manufacturing...

Страница 26: ...ructions If you cannot reach your gas supplier call the fire department C Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand don t...

Страница 27: ...ut of the gas piping 7 With the control knob pushed in push and release the piezo ignitor button to light the ODS pilot The pilot is located on the right side of the heater behind the front log and in...

Страница 28: ...9 Release the control knob If the knob does not pop out when released stop and immediately call your service technician or gas supplier If the ODS pilot will not stay lit after several tries push and...

Страница 29: ...ase the piezo ignitor button to light the pilot 8 Continue pushing the control knob in for an additional 60 seconds to prevent the flame detector from shutting off the gas while the probe is warming u...

Страница 30: ...d previously Instead of pushing and releasing the piezo button light a match and hold the flame to the end of the pilot and ignite the pilot 3 After control knob has been released and pilot stays lit...

Страница 31: ...e particles and dust from the front and rear burner control and piezo covers and grate weldment Inspect and clean rear burner air intake holes Remove lint or particles with vacuum brush or pipe cleane...

Страница 32: ...REPLACEMENT PARTS LIST Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal inj...

Страница 33: ...00K0632 00K0632 10 Knob Control 1 18D0602 18D0602 18D0602 18D0602 Milli volt Control 4 Control Valve 1 14D0467 14D0468 14D0467 14D0468 5 Regulator Valve N A N A N A N A 6 Main Injector 1 14D0588 00K0...

Страница 34: ...itor 2 Replace ignitor 3 Reconnect ignitor cable 4 Free ignitor cable if pinched by any metal or tubing 5 Replace ignitor cable 6 Replace piezo ignitor 1 Ventilate room Stop using odor causing product...

Страница 35: ...ally clogged burners orifice 1 LP regulator shut down due to inlet pressure too high REMEDY 1 Press in control knob fully 2 After ODS pilot lights keep control knob pressed in for 30 seconds 3 Fully o...

Страница 36: ...r in accordance with the installation instructions The Limited Lifetime Warranty will also be void if the appliance is not operated and maintained according to the operating instructions supplied with...

Отзывы: