Danger: This heater, as any gas-
fired appliance, can produce
poisonous carbon monoxide
along with other combustion
products.  Carbon monoxide, in
strong concentrations, can
cause sickness, serious
personal injury and death.

Early signs of carbon monoxide
poisoning resemble the flu, with
headache, dizziness and/or
nausea.  If you have these signs,
the heater may not be working
properly.   Get fresh air at once!
Immediately have heater
serviced by a qualified
technician.

Some people (pregnant
women, persons with heart or
lung disease, anemia, those
under the influence of alcohol,
those at high altitudes) are
more affected by carbon
monoxide than others.

Danger: Operation of this heater
on gases for which it is not
equipped may lead to carbon
monoxide poisoning.

Warning: This heater cannot be
converted to a gas other than the
type for which it was equipped
at the factory.

Warning:   Any change to this
heater or its controls can be
dangerous.

I

MPORTANT

  I

NFORMATION

1

Study these instructions carefully before beginning the installation of
this heater. These instructions contain information to be used as a guide
during the installation and use of this heater.  Critically important safety
information is provided in gray blocks along the edges of many pages.
These instructions must be followed for safe, efficient, and trouble-free
operation of this heater.

Before installing the heater, inspect it thoroughly for shipping damage
and missing parts.  If any damage or missing parts are detected, report
this to the dealer from whom you purchased the heater and get the
deficiency corrected before installing and using the heater.  Do not install
or use a damaged or incomplete heater.

The installer of this heater must describe the operation of the heater to
the people who will be operating it and leave this instruction manual with
the operator of the heater.

Do not use this room heater if any part has been under water.  Immediately
call a qualified service technician to inspect the room heater and to
replace any part of the control system and any gas control which has
been under water.

When properly installed, used and maintained, this heater should not
produce carbon monoxide in dangerous quantities.  However, since
carbon monoxide can be deadly poisonous, the installer and all users of
this heater should read and follow these instructions carefully.

The type gas this heater is equipped for, and the only type gas supply it
should be attached to, is specified on a label affixed to the left side of the
heater’s chamber located just behind the cabinet front. An additional label
indicating the correct gas type is affixed to the bottom of the heater.

The input rating in Btu/hr for each of the heaters described by this manual
is as specified below in Table 1.

T

ABLE

 1

53D9013. Rev 1 03/03

WARNING: D

O

 

NOT

 

ALLOW

 

FANS

 

TO

 

BLOW

 

DIRECTLY

 

INTO

 

THE

FIREPLACE

. A

VOID

 

ANY

 

DRAFTS

 

THAT

 

ALTER

BURNER

 

FLAME

 

PATTERNS

.

HEATERS BTU/HR RATING

30,000

20,000

10,000

BTU/HR RATING

BTU/HR RATING

BFVF3M

BFVF2M

BFVF1M

MODEL NUMBER

MODEL NUMBER

Содержание BFVF1M

Страница 1: ...CALL YOUR GAS SUPPLIER FROM A NEIGHBOR S PHONE FOLLOW THE GAS SUPPLIER S INSTRUCTIONS IF YOU CANNOT REACH YOUR GAS SUPPLIER CALL THE FIRE DEPARTMENT WARNING IF THE INFORMATION IN THIS MANUAL IS NOT FO...

Страница 2: ...ILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM WITH THE HEATER DO NOT PLACE CLOTHING OR OTHER FLAMMABLE MATERIAL ON OR NEAR THE HEATER ANY SAFETY SCREEN OR GUARD REMOVED FOR SERV...

Страница 3: ...ing damage and missing parts If any damage or missing parts are detected report this to the dealer from whom you purchased the heater and get the deficiency corrected before installing and using the h...

Страница 4: ...B GLASS IN TOP TAB GLASS IN PROPER POSITION PROPER POSITION WILL BE IN FRONT WILL BE IN FRONT FOR SHIPPING FROM FOR SHIPPING FROM CENTER TAB GLASS CENTER TAB GLASS IN PROPER POSITION IN PROPER POSITIO...

Страница 5: ...t Tube Assembly Elbow 3 8 NPT x 3 8 CC No Nut Pilot LP Gas Pilot NAT Gas Burner Manifold Tube Assembly Split Nut Brass Orifice LP Gas Orifice NAT Gas Burner Assembly Inlet Fitting Assembly Pntd Regula...

Страница 6: ...STALLATION AND ADJUSTMENT or TROUBLESHOOTING sections of this manual The control system on this heater serves several functions It regulates the incoming gas to the correct pressure for the combustion...

Страница 7: ...e minimum clearances see Figure 1 between combustible materials and a wall mounted heater are Back 0 inches mount directly on wall Floor 3 inches Sides 4 inches on each side of the heater Top 36 inche...

Страница 8: ...be installed in a bedroom If a blue flame heater is installed in a bedroom it must be wall mounted Floor stand mounted heaters are prohibited in bedrooms FLOOR PROTECTION Some Flooring materials will...

Страница 9: ...aded joints of gas piping must be resistant to the action of liquefied petroleum gas Gas piping must be of sufficient size to provide a minimum natural gas pressure at the appliance of 7 inches water...

Страница 10: ...NSTALLED AS A FREESTANDING HEATER AS A FREESTANDING HEATER FLOOR STAND SOLD AS AN ACCESSORY FLOOR STAND SOLD AS AN ACCESSORY FLOOR PROTECTION REQUIRED FLOOR PROTECTION REQUIRED FOR ANY COMBUSTIBLE FLO...

Страница 11: ...put rating of all gas fired appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1 000 Btu per hour 4 8m per kW of the aggregate input...

Страница 12: ...ve off carbon monoxide an odorless poisonous gas If this heater shuts off during operation do not relight it until you provide additional fresh air If permanent provisions for providing additional fre...

Страница 13: ...wers acceptable for use on these heaters The use of any other blower could adversely and dangerously affect the operation of these heaters The blower should be installed on the heater before the heate...

Страница 14: ...TO WALL STUDS NOT DRIVE ANCHORS INTO WALL STUDS FLAT SURFACES OF ANCHOR BLADES FLAT SURFACES OF ANCHOR BLADES MUST BE PARALLEL TO THE FLOOR MUST BE PARALLEL TO THE FLOOR DO NOT INSTALL ANCHOR WITH FLA...

Страница 15: ...s on back of the heater Insert two screws from the bag of fasteners through the holes in the standoffs Tighten the screws into the wall until the heater is firmly secured to the wall See Figure 6 Proc...

Страница 16: ...do the following Turn the gas off at the shutoff valve Loosen the four screws which secure the control s mounting bracket Item No 23 of PARTS DIAGRAM found in the upper right hand corner of the heater...

Страница 17: ...er s control knob to Pilot Allow the main burner to cool Reinstall the heater s front panel See Figure 6 As the front panel is being installed verify that the glass is in it s proper position in the w...

Страница 18: ...knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service technician Force or attempted repair may result in a fire or explosion D Do not use th...

Страница 19: ...ill not stay lit after several tries turn the gas control knob clockwise to OFF and call your service technician or gas supplier 7 When the pilot is lit and burning steadily depress the control knob s...

Страница 20: ...stible materials gasoline and other flammable liquids 9 Do take the necessary precautions during any pressure testing of the heater s gas supply piping system 10 Do keep children and mentally impaired...

Страница 21: ...UT THE FACTORY INSTALLED DRESS GUARD IN PLACE ANY SAFETY SCREEN OR GUARD REMOVED FOR SERVICING AN APPLIANCE MUST BE REPLACED PRIOR TO OPERATING THE APPLIANCE The pilot gas flow is not adjustable on th...

Страница 22: ...r replacements must be performed by a qualified person Do not replace any component with a different type Only use components supplied by the manufacturer of this heater 20 Control knob binds Won t po...

Страница 23: ...nsequential damages so the above limitation or exclusion may not apply to you 4 This warranty applies only to the original purchaser and may not be transferred 5 This warranty applies only to a gas he...

Страница 24: ...ATTENTION APPLIANCE INSTALLER PLEASE RETURN THESE OPERATING AND INSTALLATION INSTRUCTIONS TO THE APPLIANCE FOR CONSUMER USE 53D9013 REV 1 03 03...

Отзывы: