Important Information ............................................................................................ ..1
Parts Diagram and List ..................................................................... .................2-3
How This Appliance Operates .................................................................... ........ ..4
Selecting A Location ............................. ............. ........................... ....... . .......... ......5-6
Gas Piping and Pressure Requirements .......................................................... ........7-8
Combustion and Ventilation Air Requirements .................................................. ......9-10
Installation and Adjustment .  ...... ....... .. ................... ................................ ....... .......11-15
Lighting and Operating Heater .................................... .............. ...... ............. .....16-17
Safety Checklist ......... ................................. ................................... .................18
Maintenance ......... ........................ ....................................................... ...............19
Troubleshooting ..................... ... .......................................................... ......... ...........20
Warranty . ............................. .. .. .......................................... ..... ...........................21

Your heater has been designed for years of safe, efficient, and trouble-free operation provided the
instructions in this manual are followed.  To help insure your safety, it is very important that you take time
to read this entire manual before installing or operating this heater.

T

ABLE

 

OF

  C

ONTENTS

53D9013. Rev 1 03/03

C

AUTION

• D

UE

 

TO

 

HIGH

 

TEMPERATURES

THE

 

HEATER

 

SHOULD

 

BE

 

LOCATED

 

OUT

 

OF

 

TRAFFIC

 

AND

 

AWAY

 

FROM

FURNITURE

 

AND

 

DRAPERIES

.

• C

HILDREN

 

AND

 

ADULTS

 

SHOULD

 

BE

 

ALERTED

 

TO

 

THE

 

HAZARD

 

OF

 

HIGH

 

SURFACE

 

TEMPERATURE

 

AND

SHOULD

 

STAY

 

AWAY

 

TO

 

AVOID

 

BURNS

 

OR

 

CLOTHING

 

IGNITION

.

• Y

OUNG

 

CHILDREN

 

SHOULD

 

BE

 

CAREFULLY

 

SUPERVISED

 

WHEN

 

THEY

 

ARE

 

IN

 

THE

 

SAME

 

ROOM

 

WITH

 

THE

HEATER

.

• D

O

 

NOT

 

PLACE

 

CLOTHING

 

OR

 

OTHER

 

FLAMMABLE

 

MATERIAL

 

ON

 

OR

 

NEAR

 

THE

 

HEATER

.

• A

NY

 

SAFETY

 

SCREEN

 

OR

 

GUARD

 

REMOVED

 

FOR

 

SERVICING

 

THE

 

HEATER

 

MUST

 

BE

 

REPLACED

 

PRIOR

 

TO

OPERATING

 

THE

 

HEATER

.

• I

NSTALLATION

 

AND

 

REPAIR

 

SHOULD

 

BE

 

PERFORMED

 

ONLY

 

BY

 

A

 

QUALIFIED

 

SERVICE

 

PERSON

.

• T

HE

 

HEATER

 

SHOULD

 

BE

 

INSPECTED

 

BEFORE

 

USE

 

AND

 

CLEANED

 

AND

 

INSPECTED

 

AT

 

LEAST

 

ANNUALLY

 

BY

A

 

PROFESSIONAL

 

SERVICE

 

PERSON

. M

ORE

 

FREQUENT

 

CLEANING

 

MAY

 

BE

 

REQUIRED

 

DUE

 

TO

 

EXCESSIVE

LINT

 

FROM

 

CARPETING

BEDDING

 

MATERIAL

ETC

.  I

T

 

IS

 

IMPERATIVE

 

THAT

 

CONTROL

 

COMPARTMENTS

,

BURNERS

 

AND

 

CIRCULATING

-

AIR

 

PASSAGEWAYS

 

OF

 

THE

 

HEATER

 

BE

 

KEPT

 

CLEAN

.

• T

HIS

 

APPLIANCE

 

IS

 

INTENDED

 

FOR

 

SUPPLEMENTAL

 

HEATING

.

F

OR

 M

ASSACHUSETTS

 R

ESIDENCES

 O

NLY

:

• T

HIS

 

PRODUCT

 

MUST

 

BE

 

INSTALLED

 

BY

 

A

 

LICENSED

 

PLUMBER

 

OR

 

GAS

 

FITTER

 

WHEN

 

INSTALLED

 

WITHIN

THE

 C

OMMONWEALTH

 O

F

 M

ASSACHUSETTS

. F

LEXLINE

 

INSTALLATION

 

MUST

 

NOT

 

EXCEED

 36 

INCHES

.

WARNING: A

NY

 

CHANGE

 

TO

 

THIS

 

HEATER

 

OR

 

ITS

 

CONTROLS

 

CAN

 

BE

 

DANGEROUS

.

WARNING: F

AILURE

 

TO

 

KEEP

 

THE

 

PRIMARY

 

AIR

 

OPENINGS

 

OF

 

THE

 

BURNERS

 

CLEAN

 

MAY

 

RESULT

 

IN

SOOTING

 

AND

 

PROPERTY

 

DAMAGE

.

Содержание BFVF1M

Страница 1: ...CALL YOUR GAS SUPPLIER FROM A NEIGHBOR S PHONE FOLLOW THE GAS SUPPLIER S INSTRUCTIONS IF YOU CANNOT REACH YOUR GAS SUPPLIER CALL THE FIRE DEPARTMENT WARNING IF THE INFORMATION IN THIS MANUAL IS NOT FO...

Страница 2: ...ILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM WITH THE HEATER DO NOT PLACE CLOTHING OR OTHER FLAMMABLE MATERIAL ON OR NEAR THE HEATER ANY SAFETY SCREEN OR GUARD REMOVED FOR SERV...

Страница 3: ...ing damage and missing parts If any damage or missing parts are detected report this to the dealer from whom you purchased the heater and get the deficiency corrected before installing and using the h...

Страница 4: ...B GLASS IN TOP TAB GLASS IN PROPER POSITION PROPER POSITION WILL BE IN FRONT WILL BE IN FRONT FOR SHIPPING FROM FOR SHIPPING FROM CENTER TAB GLASS CENTER TAB GLASS IN PROPER POSITION IN PROPER POSITIO...

Страница 5: ...t Tube Assembly Elbow 3 8 NPT x 3 8 CC No Nut Pilot LP Gas Pilot NAT Gas Burner Manifold Tube Assembly Split Nut Brass Orifice LP Gas Orifice NAT Gas Burner Assembly Inlet Fitting Assembly Pntd Regula...

Страница 6: ...STALLATION AND ADJUSTMENT or TROUBLESHOOTING sections of this manual The control system on this heater serves several functions It regulates the incoming gas to the correct pressure for the combustion...

Страница 7: ...e minimum clearances see Figure 1 between combustible materials and a wall mounted heater are Back 0 inches mount directly on wall Floor 3 inches Sides 4 inches on each side of the heater Top 36 inche...

Страница 8: ...be installed in a bedroom If a blue flame heater is installed in a bedroom it must be wall mounted Floor stand mounted heaters are prohibited in bedrooms FLOOR PROTECTION Some Flooring materials will...

Страница 9: ...aded joints of gas piping must be resistant to the action of liquefied petroleum gas Gas piping must be of sufficient size to provide a minimum natural gas pressure at the appliance of 7 inches water...

Страница 10: ...NSTALLED AS A FREESTANDING HEATER AS A FREESTANDING HEATER FLOOR STAND SOLD AS AN ACCESSORY FLOOR STAND SOLD AS AN ACCESSORY FLOOR PROTECTION REQUIRED FLOOR PROTECTION REQUIRED FOR ANY COMBUSTIBLE FLO...

Страница 11: ...put rating of all gas fired appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1 000 Btu per hour 4 8m per kW of the aggregate input...

Страница 12: ...ve off carbon monoxide an odorless poisonous gas If this heater shuts off during operation do not relight it until you provide additional fresh air If permanent provisions for providing additional fre...

Страница 13: ...wers acceptable for use on these heaters The use of any other blower could adversely and dangerously affect the operation of these heaters The blower should be installed on the heater before the heate...

Страница 14: ...TO WALL STUDS NOT DRIVE ANCHORS INTO WALL STUDS FLAT SURFACES OF ANCHOR BLADES FLAT SURFACES OF ANCHOR BLADES MUST BE PARALLEL TO THE FLOOR MUST BE PARALLEL TO THE FLOOR DO NOT INSTALL ANCHOR WITH FLA...

Страница 15: ...s on back of the heater Insert two screws from the bag of fasteners through the holes in the standoffs Tighten the screws into the wall until the heater is firmly secured to the wall See Figure 6 Proc...

Страница 16: ...do the following Turn the gas off at the shutoff valve Loosen the four screws which secure the control s mounting bracket Item No 23 of PARTS DIAGRAM found in the upper right hand corner of the heater...

Страница 17: ...er s control knob to Pilot Allow the main burner to cool Reinstall the heater s front panel See Figure 6 As the front panel is being installed verify that the glass is in it s proper position in the w...

Страница 18: ...knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service technician Force or attempted repair may result in a fire or explosion D Do not use th...

Страница 19: ...ill not stay lit after several tries turn the gas control knob clockwise to OFF and call your service technician or gas supplier 7 When the pilot is lit and burning steadily depress the control knob s...

Страница 20: ...stible materials gasoline and other flammable liquids 9 Do take the necessary precautions during any pressure testing of the heater s gas supply piping system 10 Do keep children and mentally impaired...

Страница 21: ...UT THE FACTORY INSTALLED DRESS GUARD IN PLACE ANY SAFETY SCREEN OR GUARD REMOVED FOR SERVICING AN APPLIANCE MUST BE REPLACED PRIOR TO OPERATING THE APPLIANCE The pilot gas flow is not adjustable on th...

Страница 22: ...r replacements must be performed by a qualified person Do not replace any component with a different type Only use components supplied by the manufacturer of this heater 20 Control knob binds Won t po...

Страница 23: ...nsequential damages so the above limitation or exclusion may not apply to you 4 This warranty applies only to the original purchaser and may not be transferred 5 This warranty applies only to a gas he...

Страница 24: ...ATTENTION APPLIANCE INSTALLER PLEASE RETURN THESE OPERATING AND INSTALLATION INSTRUCTIONS TO THE APPLIANCE FOR CONSUMER USE 53D9013 REV 1 03 03...

Отзывы: