background image

S

AFETY

  C

HECKLIST

Continued safe operation of this heater requires, but is not limited to, these “Do’s” and “Don’ts”:

DO’S:

1.     Do make the installation according to local codes or, in the absence of local codes, with latest edition of the

National Fuel Gas Code ANSI Z223.1/NFPA 54.

2.

Do provide ample fresh air when using heater.

3.

Do use only soap-water solution or a liquid gas leak detector when checking for leaks.

4.

Do operate the heater only with the factory-installed dress guard and front glass in place.

5.

Do keep clothing, furniture, draperies and other flammable materials away from the heater.

6.

Do inspect the heater periodically and clean it as necessary.

7.     Do keep the area around the heater clear and free from combustible materials, gasoline and other flammable

liquids.

9.

Do take the necessary precautions during any pressure testing of the heater’s gas supply piping system.

10. Do keep children and mentally impaired persons away from the heater.

DON’TS:

1.

Don’t use candles, matches or any source of ignition when checking for leaks.

2.

Don’t operate the heater without the dress guard and front glass in place.

3.

Don’t place any combustible material near the heater.

4.

Don’t allow lint and dust to accumulate around the heater.

5.

Don’t close any openings in the heater cabinet or alter the cabinet in any way.

6.

Don’t use or store gasoline or any flammable or explosive material in the area heated by this heater.

7.

Don’t attempt to adjust the pilot flame.

8.

Don’t block or alter air flow into and away from the heater (other than installing an optional blower).

9.

Don’t allow children to play near or with the heater.

18

53D9013. Rev 1 03/03

Содержание BFVF1M

Страница 1: ...CALL YOUR GAS SUPPLIER FROM A NEIGHBOR S PHONE FOLLOW THE GAS SUPPLIER S INSTRUCTIONS IF YOU CANNOT REACH YOUR GAS SUPPLIER CALL THE FIRE DEPARTMENT WARNING IF THE INFORMATION IN THIS MANUAL IS NOT FO...

Страница 2: ...ILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM WITH THE HEATER DO NOT PLACE CLOTHING OR OTHER FLAMMABLE MATERIAL ON OR NEAR THE HEATER ANY SAFETY SCREEN OR GUARD REMOVED FOR SERV...

Страница 3: ...ing damage and missing parts If any damage or missing parts are detected report this to the dealer from whom you purchased the heater and get the deficiency corrected before installing and using the h...

Страница 4: ...B GLASS IN TOP TAB GLASS IN PROPER POSITION PROPER POSITION WILL BE IN FRONT WILL BE IN FRONT FOR SHIPPING FROM FOR SHIPPING FROM CENTER TAB GLASS CENTER TAB GLASS IN PROPER POSITION IN PROPER POSITIO...

Страница 5: ...t Tube Assembly Elbow 3 8 NPT x 3 8 CC No Nut Pilot LP Gas Pilot NAT Gas Burner Manifold Tube Assembly Split Nut Brass Orifice LP Gas Orifice NAT Gas Burner Assembly Inlet Fitting Assembly Pntd Regula...

Страница 6: ...STALLATION AND ADJUSTMENT or TROUBLESHOOTING sections of this manual The control system on this heater serves several functions It regulates the incoming gas to the correct pressure for the combustion...

Страница 7: ...e minimum clearances see Figure 1 between combustible materials and a wall mounted heater are Back 0 inches mount directly on wall Floor 3 inches Sides 4 inches on each side of the heater Top 36 inche...

Страница 8: ...be installed in a bedroom If a blue flame heater is installed in a bedroom it must be wall mounted Floor stand mounted heaters are prohibited in bedrooms FLOOR PROTECTION Some Flooring materials will...

Страница 9: ...aded joints of gas piping must be resistant to the action of liquefied petroleum gas Gas piping must be of sufficient size to provide a minimum natural gas pressure at the appliance of 7 inches water...

Страница 10: ...NSTALLED AS A FREESTANDING HEATER AS A FREESTANDING HEATER FLOOR STAND SOLD AS AN ACCESSORY FLOOR STAND SOLD AS AN ACCESSORY FLOOR PROTECTION REQUIRED FLOOR PROTECTION REQUIRED FOR ANY COMBUSTIBLE FLO...

Страница 11: ...put rating of all gas fired appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1 000 Btu per hour 4 8m per kW of the aggregate input...

Страница 12: ...ve off carbon monoxide an odorless poisonous gas If this heater shuts off during operation do not relight it until you provide additional fresh air If permanent provisions for providing additional fre...

Страница 13: ...wers acceptable for use on these heaters The use of any other blower could adversely and dangerously affect the operation of these heaters The blower should be installed on the heater before the heate...

Страница 14: ...TO WALL STUDS NOT DRIVE ANCHORS INTO WALL STUDS FLAT SURFACES OF ANCHOR BLADES FLAT SURFACES OF ANCHOR BLADES MUST BE PARALLEL TO THE FLOOR MUST BE PARALLEL TO THE FLOOR DO NOT INSTALL ANCHOR WITH FLA...

Страница 15: ...s on back of the heater Insert two screws from the bag of fasteners through the holes in the standoffs Tighten the screws into the wall until the heater is firmly secured to the wall See Figure 6 Proc...

Страница 16: ...do the following Turn the gas off at the shutoff valve Loosen the four screws which secure the control s mounting bracket Item No 23 of PARTS DIAGRAM found in the upper right hand corner of the heater...

Страница 17: ...er s control knob to Pilot Allow the main burner to cool Reinstall the heater s front panel See Figure 6 As the front panel is being installed verify that the glass is in it s proper position in the w...

Страница 18: ...knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service technician Force or attempted repair may result in a fire or explosion D Do not use th...

Страница 19: ...ill not stay lit after several tries turn the gas control knob clockwise to OFF and call your service technician or gas supplier 7 When the pilot is lit and burning steadily depress the control knob s...

Страница 20: ...stible materials gasoline and other flammable liquids 9 Do take the necessary precautions during any pressure testing of the heater s gas supply piping system 10 Do keep children and mentally impaired...

Страница 21: ...UT THE FACTORY INSTALLED DRESS GUARD IN PLACE ANY SAFETY SCREEN OR GUARD REMOVED FOR SERVICING AN APPLIANCE MUST BE REPLACED PRIOR TO OPERATING THE APPLIANCE The pilot gas flow is not adjustable on th...

Страница 22: ...r replacements must be performed by a qualified person Do not replace any component with a different type Only use components supplied by the manufacturer of this heater 20 Control knob binds Won t po...

Страница 23: ...nsequential damages so the above limitation or exclusion may not apply to you 4 This warranty applies only to the original purchaser and may not be transferred 5 This warranty applies only to a gas he...

Страница 24: ...ATTENTION APPLIANCE INSTALLER PLEASE RETURN THESE OPERATING AND INSTALLATION INSTRUCTIONS TO THE APPLIANCE FOR CONSUMER USE 53D9013 REV 1 03 03...

Отзывы: