30
61D0006
Figure 37 - Hole in Side Brick Liner
Back Brick
Liner
Side Brick
Liner
Hole
PASSING GAS LINE THROUGH FIREPLACE WALL
1. Locate recessed area in side brick side liner.
2. Lightly tap recessed area with a hammer until a round hole is
tapped out.
See Figure 37
.
3. Remove the two (2) screws that hold cover plates on jacket
wrap. Discard cover plate.
4. Install the gas pipe through the tube between the firebox and
jacket.
5. Attach the gas appliance to the gas pipe according to the appli-
ance makers instructions.
6. Pack insulation around the pipe to prevent air flowing through
the tube either into or out of the firebox for proper seal.
1. Turn gas off at the appliance.
2. Turn the gas on at the cut off valve.
3. Test the gas line connections for leaks with soapy water solution or a liquid leak
detector. DO NOT USE A MATCH OR OTHER FLAME SOURCE TO CHECK FOR GAS
LEAKS. If a gas leak is detected, turn the gas off immediately. Fix the leak.
W
ARNING
7. Follow the instructions provided by the manufacturer for testing and adjusting gas line.
INSTALLING GAS APPLIANCE