background image

H.

INLET & OUTLET CONNECTIONS

 See  Fig 2

Fig 2 

Inlet

 & 

Outlet

 connections &

drain connection 

Remove both salt lid and main cover to access inlet and

outlet connections.

Remove grey retaining clips and BSP connection points

(indicated red and blue in fig 2). Connect inlet hose to

male BSP connection point (indicated red in fig 2) and

connect outlet hose to BSP connection (indicated blue

in fig 2), using supplied washers and tighten to seal.

Then reinsert BSP connection points back into valve

body. Fit grey clips. The connection points are designed to 

rotate once inserted in valve body. This removes any

stress/pressure placed upon the angle/direction of the

hoses when connecting them to the 

Rapid-Fit bypass.

Under no circumstances use washing machines hoses or plumb the softener in solid 

copper pipe. 

I.

DRAIN CONNECTION

2.5mtrs of white low pressure drain hose is supplied with the unit. This is to be used

for both the drain and overflow. The 

drain connection

 

is the white elbow on the side

(pictured green in Fig 2). Fix drain hose to white barbed elbow with jubilee clip

(supplied).

Run the drain hose to either an upstand or an outside drain. A minimum air gap of

20mm should exist at the end of the drain line.

If you need to extend the drain hose, this can be done by connecting to a 15mm

copper tube for a maximum run of 4 metres, with a minimum daytime pressure of

40 psi. Over  4 metres please use 22mm copper tube.

Ensure that the drain hose is adequately fixed to the copper pipe.

The drain hose must not dip or be kinked in any way, as this will lead to an overflow

of the machine.

Uphill? 

The white flexible drain hose can run uphill internally, for a maximum of 3

feet, with a minimum water pressure of 40 psi.

Softened water will have no adverse effect on a septic tank.

Under no circumstances should the softener drain and overflow share the same

pipe. This could lead to foul smells entering the salt cabinet from the main drain via

the overflow. Also if the common drain ever gets blocked, the regen water can re-

enter the softener via the overflow pipe.

Содержание PREMIO HE

Страница 1: ...Installer User Guide Effective October 2021 T 01986 784759 F 01986 784769 ULTRA HE PREMIO HE Model No ...

Страница 2: ...tance between the softener and the drain should be as short as possible to ensure that both the drain and the overflow are not subject to freezing or over 120 F 49 C If siting the softener within a kitchen cupboard loft etc ensure that the base floor is adequately supported If the softener is being installed in your loft 1st 2nd floor etc it is strongly recommended to house the softener within a 2...

Страница 3: ... INSTALL RAPID FIT BYPASS Form an installation as per Fig 1 Below See page 18 for more information SOF TO T SERVICE WATER Mains Outside water tap to FIG 1 Soft water connection I T T Mains point 1 water 4 speedflt connection Valve Pressure If required Limiting Stop Incoming tap on main Checklist SOFTENER WATER Power Drain Hose Drain Cllp hose through Overflow and outside wall over tennlnated gulle...

Страница 4: ...nd overflow The drain connection is thewhiteelbow ontheside picturedgreeninFig2 Fix drain hose to white barbed elbow with jubilee clip supplied Run the drain hose to either an upstand or an outside drain A minimum air gap of 20mm should exist at the end of the drain line If you need to extend the drain hose this can be done by connecting to a 15mm copper tube for a maximum run of 4 metres with a m...

Страница 5: ...ER HARDNESS These instructions apply to the enclosed test kit only Run hard water tap for approx 1 minute and rinse the test tube well Fill the test tube up to the 10ml level Add 2 drops of the dark solution and mix gently If the water sample contains hardness it will turn red Add the dark solution in batches of 5 drops holding the dropper bottle at 45 degrees Mix gently after each 5 drops Count t...

Страница 6: ...ime you want to reset a figure press the up or down arrow to turn the display back on Then wait until the display changes to the relevant setting and then reprogramme as required P FLUSH SOFTENER IMPORTANT Place Rapid Fit bypass in Service position by pushing plunger as per directional arrow see Fig B previous page Check for leaks Leave a soft mains tap e g bathroom wash hand basin to run for a mi...

Страница 7: ...ener is in Service i e not when regenerating Further Information Fig C Do not worry if your softener regenerates during the day This is the Smaart Programme initiating an additional mini regeneration as the softener does not have enough soft water to last you until the next programmed regeneration of 2am A regeneration typically lasts 42 minutes for the Ultra HE and 63 minutes for the Premio HE Du...

Страница 8: ...worry all of your settings will be saved Reverse the above and place bypass back in Service upon your return Reset time if necessary by reverting to Set Time of Day Activate a manual regeneration by pressing left hand button on controller Display will countdown from 15 to zero Please be aware that during the regeneration the softener goes onto automatic hard water bypass so it is recommended to us...

Страница 9: ...Remove salt lid and side access panel 9 REVERSIBLE CONNECTIONS ...

Страница 10: ...Remove top cover 1 2 10 ...

Страница 11: ...Remove any internal packaging 11 ...

Страница 12: ...tly until it you blend 60 70ppm of hardness back into the soft water Test kits are available from Monarch Water This operation may be required if a reen blue build up in the scale is apparent after the softener is installed ig 1 Fig 2 Inlet hose Outlet Inlet Outlet hose Drain hose Overflow hose Loosen the jubilee clip and disconnect the drain tubing from the white barb inside the cabinet Then remo...

Страница 13: ...Remove the blue clip Push the white collar against the valve body Release connection while pressing the collar 13 Disconnect the air check from the valve ...

Страница 14: ...unit supports at the top of the vessels 180 degrees Undo the large nut at the base of the main valve body take out the valve and twist 180 degrees until the connections are on the other side Retighten the large nut to secure the valve in place 14 ...

Страница 15: ...s Please note that this question does NOT apply to the Plumbsoft models IMPORTANT It is important that the softener is kept full of either tablet or block salt at all times This goes in the chamber under the curved lid at the front of the machine for Solo models and under the Blue lid for Premio models 7 Unit with bypass fully connected Note Protruding male vertical piece on top of blender valve i...

Страница 16: ...using the jubilee clip this can only be done once it is in the cabinet En sure the drain hose is not kinked Finally put the top cover salt lid and side panel back into place Remove the drain elbow from the side of the cabinet and place it on the opposite side 16 ...

Страница 17: ...hine should have either hard or soft water please contact your dishwasher manufacturer but remember they want to sell you spare parts to replace those that get scaled up 7 Steam Irons We do not recommend the use of soft water in your steam iron as most are designed for hard water and to be periodically de scaled Alternatively please use de ionised water 8 Outside Tap It is recommended to leave you...

Страница 18: ...and TABLET SALT ONLY for the PREMIO HE 6 The use of any other hoses than those provided Under no circumstances use washing machine hoses 7 The build up of salt fines in the bottom of the salt compartment Although Monarch recommends Ultimate please note it is the customers responsibility to ensure the salt is of good condition when used 8 The effect of aggressivewater the degradation and or blindin...

Страница 19: ...ge guarantee as determined by the model range of softeners i e Unit with 7 years parts All parts sent back to Monarch are at the expense of the sending parties All repaired or replaced items will be returned to the sender on a no charge basis whilst covered by the parts exchange guarantee Once the parts exchange guarantee has expired Monarch reserves the right to make a charge for any postage deli...

Страница 20: ...or Loctite SI 5331 may be used Simply apply tomale thread of noryl bypass adaptor and to inside of female thread of brass fitting Fig 2 In all cases fibre washer must be used 3 Tighten male noryl connection into brass adaptor solidly up against fibre washer Fig 3 Remove any excess sealant inside brass noryl adaptor assembly 4 Place assembled connection back into bypass and fix with clip Fig 4 5 Ru...