background image

Replacing the Battery

1.  Be sure that the replacement battery is 

plugged into the PCB firmly. 

2.  Carefully place the right half (1055-4241-

111) onto the left (1055-4242-111). 

3.  Align the display board [E], battery [F], 

and main PCB [G] into the slots provide in 

the case. 

4. 

Align the display and battery first, then 

from the front of the unit, guide the PC 

Board into the retaining slots with a 

wooden stick. Ensure the trigger wires [H] 

and DC Jack [I] are properly in place.

[F]

[E]

[G]

[H]

[I]

[J]

[K]

Nova-Strobe Battery Replacement 1/2022 v3.1

[D1]

[D2]

[D1]

Top half of the 

Battery Holder 

sits in the right 

side case. 

Note the position 

of the cradle 

guides

Helpful Tip:

Placing the left side of the case  

on a roll of tape or other lift  

will prevent the speed knob  

from pushing the PCB out of  

the retaining slots when  

aligning all.

www.monarchinstrument.com 

5.  Fasten both halves using two 2

"

 self tapping screws [D] 

(1053-3328-001) through the body of the right half. Do 

not over tighten screws.

6.  Gently pry apart case halves at the base of the handle 

and insert T-nut [J] (1053-0270-001) into slot in left 

handle.

7.  Slip knotted end of wrist strap [K] (3051-2000-015) over 

left half handle standoff and through slot provided.

8.  Carefully press case handles together, ensuring the 

wrist strap fits into the notch provided and no wires are 

pinched between the case halves.

9. 

Reattach the reflector housing. 

10. Do not over tighten screws [C], [D1], [D2].

 [email protected]