background image

6

Specifications*

ROS-P Remote Optical Sensor

Operating Envelope

Up to 3 ft. [0.9 m] and 45° from reflective target

Speed Range

1 to 250,000 RPM

Illumination Source

Visible red LED, 5 V dc @ 30 mA

Operating Temperature

14 

°F to 158 °F (-10 °C to 70 °C)

Output Signal

5 to 0 V dc TTL compatible pulse

On-Target Indicator

Green LED on end cap

Material

303 Stainless steel

Lens

Acrylic plastic

Cable Length

8 ft. [2.5 m] Standard

Dimensions

Threaded Tube: 2.90 in. L x 0.625

 in.

 diameter [M16 

x 1.5 x 74 mm] supplied with two M16 jam nuts 

and mounting bracket

*Specifications are subject to change without notice.

ROS-P and mounting bracket Dimensions

 

 

M16 x 1.5 

Green 

On Target LED 

0.62” [15.9mm] 

2.90” [74.0mm] 

-

"

"

Содержание 6150-020

Страница 1: ...tion Manual SPSR 115 230 Self Powered Sensor TTL Pulse Output 15 Columbia Drive Amherst NH 03031 USA Phone 603 883 3390 Fax 603 886 3300 Email support monarchinstrument com Website www monarchinstrume...

Страница 2: ...distributor for details SAFEGUARDS AND PRECAUTIONS Read and follow all instructions in this manual carefully and retain this manual for future reference Do not use this instrument in any manner incon...

Страница 3: ...PSR Interface Module 1 2 1 1 Connections 2 2 1 2 Controls 2 2 1 3 RechargingtheBatteries 3 3 0 SPSR 115 230SERIES SPSR IMWITHROS P 3 3 1 ROS P 3 3 2 Operating the SPSR as a Triggering Source 4 4 0 BAT...

Страница 4: ...ed sensor IRS P or an amplified magnetic sensor MT 190P may also be combined with the SPSR IM Interface Module when appropriate See separate instructions for these configurations 2 0 FUNCTIONS AND OPE...

Страница 5: ...L DC on the SPSR IM and connect the wall unit to the appropriate power source 2 1 2 Controls The POWER switch on the SPSR IM controls both the operation and the charging of the system The unit will on...

Страница 6: ...The SPSR 115 230 consists of the SPSR IM Interface Module described above an ROS P Remote Optical Sensor with eight foot cable and mounting bracket and an SPSR U 115 230 V ac external power connectio...

Страница 7: ...ace Module sections entitled Connections and Controls The pulse signal on the connector marked OUTPUT provides a sharp leading edge for reliable and repeatable triggering of the connected device This...

Страница 8: ...optionally the output can be open collector external pull up required Bandwidth 0 to 100 kHz Battery Current Draw 12 mA with k load operational 7 5 V Input Current Draw 14 mA with k load operational P...

Страница 9: ...utput Signal 5 to 0 V dc TTL compatible pulse On Target Indicator Green LED on end cap Material 303 Stainless steel Lens Acrylic plastic Cable Length 8 ft 2 5 m Standard Dimensions Threaded Tube 2 90...

Страница 10: ...liance Both the SPSR IM and ROS P units are CE compliant Low Voltage Directive LVD 2014 35 EU Electromagnetic Compatibility Directive EMC 2014 30 EU Restriction of Hazardous Substances RoHS Directive...

Страница 11: ...rigger Sensor Amplifier with 8 ft 2 5 m cable 0 250 6 4 mm operating gap from target 2 L x 5 8 50 8 x 15 9 mm EC 25P 25 foot 7 6 m Extension Cable for remote sensors with male 1 8 3 5 mm phone plug to...

Страница 12: ...nstrument is committed to excellence and quality in manufacturing sales and service The Professional s Choice Track It Data Loggers Panel Tachometers DataChart Paperless Recorders Speed Sensors Portab...