background image

8

6.0  SENSORS/OPTIONS AND ACCESSORIES

ROS-P  

Remote Optical Sensor with 8 ft. [2.5 m] cable

  

and mounting bracket

ROS-P-25   Remote Optical Sensor with 25 ft. [7.6 m] cable

  

and mounting bracket

ROLS-P   Remote Optical Laser Sensor with 8 ft. [2.5 m]

  

cable and mounting bracket

IRS-P  

Infrared Sensor with 8 foot [2.5 m] cable for use

 

without reflective target at 0.5 inch [12.7 mm]  

 

gap (5 to 500,000 RPM)

MT-190P   Magnetic Trigger Sensor/Amplifier with 8 ft. [2.5

  

m] cable - 0.250

"

 [6.4 mm] operating gap from

  

target, 2

"

 (L) x 5/8

"

 [50.8 x 15.9 mm]

EC-25P   25 foot [7.6 m] Extension Cable for re

mote

  

sensors with male 1/8

"

 [3.5 mm] phone plug to

  

female 1/8

"

 [3.5 mm] connector

T-5  

Reflective Tape 5 ft. [1.5 m] roll, ½ inch [13

  

mm] wide

T-5WP  

Reflective Tape, waterproof, honeycomb pattern,

  

5 ft. [1.5 m] roll, 1-inch [25 mm] wide

BP-R  

Replacement NiMH Battery Pack 

(for SPSR-IM ONLY)

SPSR-U   Universal Recharger with plugs, 115/230 V ac -

  

50/60 Hz

PN: 6180-057

PN: 6180-057-25

PN: 6180-029

PN: 6180-020

PN: 6180-036

PN: 6180-028

PN: 6180-070

PN: 6180-079

PN: 6180-066

PN: 6180-059

Содержание 6150-020

Страница 1: ...tion Manual SPSR 115 230 Self Powered Sensor TTL Pulse Output 15 Columbia Drive Amherst NH 03031 USA Phone 603 883 3390 Fax 603 886 3300 Email support monarchinstrument com Website www monarchinstrume...

Страница 2: ...distributor for details SAFEGUARDS AND PRECAUTIONS Read and follow all instructions in this manual carefully and retain this manual for future reference Do not use this instrument in any manner incon...

Страница 3: ...PSR Interface Module 1 2 1 1 Connections 2 2 1 2 Controls 2 2 1 3 RechargingtheBatteries 3 3 0 SPSR 115 230SERIES SPSR IMWITHROS P 3 3 1 ROS P 3 3 2 Operating the SPSR as a Triggering Source 4 4 0 BAT...

Страница 4: ...ed sensor IRS P or an amplified magnetic sensor MT 190P may also be combined with the SPSR IM Interface Module when appropriate See separate instructions for these configurations 2 0 FUNCTIONS AND OPE...

Страница 5: ...L DC on the SPSR IM and connect the wall unit to the appropriate power source 2 1 2 Controls The POWER switch on the SPSR IM controls both the operation and the charging of the system The unit will on...

Страница 6: ...The SPSR 115 230 consists of the SPSR IM Interface Module described above an ROS P Remote Optical Sensor with eight foot cable and mounting bracket and an SPSR U 115 230 V ac external power connectio...

Страница 7: ...ace Module sections entitled Connections and Controls The pulse signal on the connector marked OUTPUT provides a sharp leading edge for reliable and repeatable triggering of the connected device This...

Страница 8: ...optionally the output can be open collector external pull up required Bandwidth 0 to 100 kHz Battery Current Draw 12 mA with k load operational 7 5 V Input Current Draw 14 mA with k load operational P...

Страница 9: ...utput Signal 5 to 0 V dc TTL compatible pulse On Target Indicator Green LED on end cap Material 303 Stainless steel Lens Acrylic plastic Cable Length 8 ft 2 5 m Standard Dimensions Threaded Tube 2 90...

Страница 10: ...liance Both the SPSR IM and ROS P units are CE compliant Low Voltage Directive LVD 2014 35 EU Electromagnetic Compatibility Directive EMC 2014 30 EU Restriction of Hazardous Substances RoHS Directive...

Страница 11: ...rigger Sensor Amplifier with 8 ft 2 5 m cable 0 250 6 4 mm operating gap from target 2 L x 5 8 50 8 x 15 9 mm EC 25P 25 foot 7 6 m Extension Cable for remote sensors with male 1 8 3 5 mm phone plug to...

Страница 12: ...nstrument is committed to excellence and quality in manufacturing sales and service The Professional s Choice Track It Data Loggers Panel Tachometers DataChart Paperless Recorders Speed Sensors Portab...

Отзывы: