3
LED Indication:
Unit operational = solid green
Unit charging = blinking red
Charging done = solid red
NOTE:
Short red blinks followed by long blink = charge error; contact
factory.
2.1.3 Recharging the Batteries
To recharge the
S
PSR-IM Interface Module batteries:
1. Connect the recharger/power supply to the
EXTERNAL DC
input
connector.
2. Connect the recharger/power supply into a working ac outlet.
3. Be sure the
POWER
switch is in the
OF
F (CHARGE)
position. The
red
CHARGE
LED will indicate that the batteries are being charged.
Allow up to 4 hours to fully charge.
3.0 SPSR-115/230 SERIES - SPSR-IM WITH ROS-P
The SPSR-115/230 consists of the SPSR-IM Interface Module described
above, an ROS-P Remote Optical Sensor with eight foot cable and mounting
bracket, and an SPSR-U (115/230 V ac) external power connection. One foot
of T-5 Reflective Tape is also supplied.
3.1 ROS-P
When connected to the SPSR-IM as described above, the ROS-P
illuminates the target with a visible red light from a high intensity LED
and detects the reflected pulses from the rotating reflective tape target
with an internal photo-detector. The ROS-P Remote Optical Sensor is
capable of detecting a reflected pulse from T-5 Reflective Tape targets
at distances of up to 3 feet and angles up to 45 degrees from the target.
The sensor is supplied with a set of two M16 jam nuts and a 90° angle
slotted aluminum mounting bracket.