Fireman‘s Microphone with 

Emergency Announcement Unit 

for PA Systems

These instructions are intended for installers 
of PA systems (chapter 4) and for users with-
out any specific technical knowledge (chap-
ter 5) . Please read the instructions carefully 
prior to operation and keep them for later 
reference .

1  Overview

Indication FIRE; starts flashing when the 
input ALARM (9) has been activated

Switch BUZZER for the alarm buzzer

Alarm buzzer; will sound when the hand- 
held microphone (8) has not been con-
nected or when the microphone is 

 

defective

LED FAULT; starts flashing when the hand-
held microphone has not been connected 
or when the microphone is defective

Control MIC LEVEL for the volume of  
microphone announcements

Jack MIC INPUT for the hand-held micro-
phone

Push-to-talk switch

Hand-held microphone; this microphone 
can be used to make announcements at 
any time

Screw terminals* INPUT 

 

ALARM for triggering an alarm via NO 
contact 

 

+24 V for power supply (200 mA)

10 

Screw terminals* for the balanced audio 
output

11 

Control SIREN LEVEL for the volume of 
the siren

12 

Control LEVEL for the volume of the  
automatic alarm announcement

13 

Announcement storage module

2  Important Notes

The unit corresponds to all relevant directives 
of the EU and is therefore marked with   .

• 

The unit is suitable for indoor use only .  
Protect it against dripping water, splash 
water and high air humidity . The admissi-
ble ambient temperature range is 0 – 40 °C .

• 

Do not place any vessel filled with liquid on 
the unit, e . g . a drinking glass .

• 

The heat produced inside the unit must be 
dissipated by air circulation; never cover 
the air vents .

• 

For cleaning only use a dry, soft cloth; never 
use water or chemicals .

• 

No guarantee claims for the unit and no  
liability for any resulting personal damage 
or material damage will be accepted if 
the unit is used for other purposes than  
originally intended, if it is not correctly con-
nected or operated, or if it is not repaired 
in an expert way .

If the unit is to be put out of oper-
ation definitively, take it to a local 
recycling plant for a disposal which 
is not harmful to the environment .

3  Applications

In the event of an alarm, the PA-26FMU is 
used for automatic reproduction of fire alarm / 
evacuation announcements in accordance 
with EN  60 846 . The alarm must be trig-
gered via a potential-free NO contact . When 
an alarm is triggered, a siren will sound for 
10 seconds before a pre-recorded MP3 file 
will be reproduced . Additional announce-
ments can be made at any time via the hand-
held microphone . These announcements will 
take priority over all other signals .

4  Installation

IMPORTANT!

 First insert the memory card 

containing the pre-recorded alarm an-
nouncements . To insert the card, the storage 
module (13) must be removed .

4.1  Inserting a memory card for 

announcements

1)  Copy the corresponding announcement 

in MP3 format to an MMC card (512 GB 
max .), SD card (2 GB max .) or SDHC card 
(32 GB max .) . It is possible to copy multiple 
MP3 files to the memory card . When an 
alarm is triggered, the files will be repro-
duced in alphabetic order . 

2)  Unscrew the announcement storage mod-

ule (13) and carefully remove the module 
from the unit . The module is internally 
connected by means of a 5-core cable .

3)  Insert the memory card (notched corner 

to the right) into the card holder of the 
module until it engages . To remove the 
card, push the card into the holder until 
it disengages .

4)  Reinsert the announcement storage 

 

module and fasten the screws .

4.2  Rack installation

The unit is designed for installation into a 
rack (482 mm / 19”), but it can also be put on 
a table . For installation into a rack, 2 RS (rack 
space = 44 .45 mm) are required . To ensure 
sufficient cooling, air must always be able to 
flow freely thought the air vents .

English
English Page

* To make handling easier, the screw terminals can 

be removed from their plug-in connections .

Содержание PA-26FMU

Страница 1: ...CTRONICS FOR SPECIALISTS ELECTRONICS FOR SPECIALISTS BEDIENUNGSANLEITUNG INSTRUCTION MANUAL MODE D EMPLOI ISTRUZIONI PER L USO ELA Feuerwehrsprechstelle Fireman s Microphone with Emergency Announcemen...

Страница 2: ......

Страница 3: ...ELECTRONICS FOR SPECIALISTS ELECTRONICS FOR SPECIALISTS ELECTRONICS FOR SPECIALISTS ELECTRONICS FOR SPECIALISTS 3 Deutsch Seite 4 English Page 6 Fran ais Page 8 Italiano Pagina 10...

Страница 4: ...m glichkeiten Das Ger t PA 26FMU dient bei einer Alarm ausl sung zum automatischen Abspie len einer Feueralarm und Evakuierungs durchsage in Beschallungsanlagen nach EN 60846 Die Alarmausl sung muss d...

Страница 5: ...rend einer Alarmausl sung kann das Mikrofon genauso genutzt werden Kap 5 1 Absatz FIRE 1 blinkt 2 Der Schalter BUZZER 2 sollte immer in der Position ON stehen Damit ist sicher gestellt das bei einem D...

Страница 6: ...resulting personal damage or material damage will be accepted if the unit is used for other purposes than originally intended if it is not correctly con nected or operated or if it is not repaired in...

Страница 7: ...ake announcements at any time Take the microphone from its holder keep the push to talk switch 7 pressed and speak into the microphone Use the control MIC LEVEL 5 to adjust the volume if required Afte...

Страница 8: ...Le PA 26FMU sert en cas de d clenchement d alarme pour lire automatiquement une annonce d alerte incendie ou d vacuation dans des installations de sonorisation selon la norme EN 60846 Le d clenchemen...

Страница 9: ...microphone Si besoin adaptez le volume avec le r glage MIC LEVEL 5 Apr s l annonce replacez le microphone sur le support Lorsqu une alarme est d clench e le microphone peut tre utilis de la m me mani...

Страница 10: ...e e all evacuazione L allarme deve scattare da un contatto NA pu lito In caso d allarme per 10s suona la sirena quindi viene riprodotto un file MP3 preceden temente memorizzato Tramite il microfono a...

Страница 11: ...o pu essere usato nello stesso modo Cap 5 1 paragrafo FIRE 1 lampeggia 2 L interruttore BUZZER 2 dovrebbe sempre trovarsi in posizione ON In questo modo assicurato che in caso di un difetto del microf...

Страница 12: ...MONACOR INTERNATIONAL GmbH Co KG Zum Falsch 36 28307 Bremen Germany Copyright by MONACOR INTERNATIONAL All rights reserved A 1804 99 01 11 2016...

Отзывы: